ページ1に含まれる内容の要旨
1105
Open Voice Tenant Station for the GF System
- INSTRUCTIONS -
The GFO-1DL and GFO-1DLF are open voice tenant stations for the GF system. The unit features door answering and
door release with up to five entrance stations, Concierge call, and the connection of an optional panic call station (GFK-
PS). A separate standard doorbell can be added to ring the unit with a unique tone. The unit includes TALK, DOOR
RELEASE, and CONCIERGE CALL buttons. Each GFO-1DL counts as 2.5 handset stations on
ページ2に含まれる内容の要旨
WIRING DIAGRAM: (Entrance panel(s) not shown) Wire junction point** TERMINAL LOCATIONS: GF-BC Common R1 Bus Line R2 GFO-1DL GFO-1DL GFO-1DL R1 R1 R1 Red R2 R2 R2 + + KE K CE C R2 R1 C C C Blk - - CE CE CE PS-2410LC K K K KE KE KE **Distribution point can be any type of terminal strip, punch down block, or suitable wire connection point for multiple bus lines of stations. Up to 20 GFO-1DL's can be run on each bus line. Doorbell GFK-PS Panic *Optional Features button* Call Swit
ページ3に含まれる内容の要旨
PROGRAMMING & OPERATION: PROGRAMMING THE SYSTEM (INDIVIDUAL BUTTON PANEL): 1. Remove faceplate of GF entrance panel. 2. Lift rubber cap located on the upper right side of the GF-DA/B speaker module. 3. Using a long slender tool, momentarily press the programming button through the hole inside the GF-DA/B. 4. The In-Use LED will blink for approximately 15 seconds, then will become steadily lit. 5. With In-USE LED steadily lit, press the TALK button momentarily on the GFO-1DL you wish to program.
ページ4に含まれる内容の要旨
OPERATION: 1. Press the tenant's call button on the entrance panel, and a ring tone will be heard at the tenant station. 1a. If a digital entrance panel is used, enter the tenant's 3 or 4 digit code or scroll to their name, then press the green-lit "bell" button on the entrance panel. 2. Answer the call at the tenant station by pressing the TALK button. NOTE: There is a brief delay when initially pressing TALK, so pause for approximately one second before speaking. 3. Release TALK button t
ページ5に含まれる内容の要旨
SPECIFICATIONS: System Capacity: Max. 100 units in a system with all GFO-1DL's. Each GFO-1DL takes the capacity of 2.5 standard GF-1DK handset models.. If intermixing, multiply each GFO-1DL in the system (including 2nd tenant stations also) by 2.5, then add the number of handsets included. Total number must not exceed 250. Communication: Push-to-talk, release-to-listen at tenant station. Press END to conclude call (like hanging up handset) Hands free from entrance panel to tenant Calling: El