ページ1に含まれる内容の要旨
User's Manual
ページ2に含まれる内容の要旨
Copyright © DENSO WAVE INCORPORATED, 2001 All rights reserved. No part of this publication may be reproduced in any form or by any means without permission in writing from the publisher. Specifications are subject to change without prior notice. All products and company names mentioned in this manual are trademarks or regis- tered trademarks of their respective holders.
ページ3に含まれる内容の要旨
Preface Please READ through these operating instructions carefully. It will enable you to operate your CU-7011 correctly. After you have finished reading the instructions, keep this manual handy for speedy reference. i
ページ4に含まれる内容の要旨
How this book is organized This manual is made up of 10 chapters and appendix. Chapter 1 Ethernet System Configuration Chapter 2 Functions of the CU-7011 Chapter 3 Components and Functions Chapter 4 CU Status Indication by LED Indicators Chapter 5 Applying Power to the CU-7011 Chapter 6 Connecting to Ethernet Chapter 7 Charging the Rechargeable Battery Cartridge Chapter 8 Displaying the CU System Information on the BHT Chapter 9 Updating the CU System Program via the BHT Chapter 10 MAC Address A
ページ5に含まれる内容の要旨
■ Related Publications BHT-7000 User's Manual BHT-7000 User's Manual "LAN Support Version" BHT-100 Series User's Manuals BHT-100 Series User's Manual "LAN Support Version" BHT-BASIC Programmer's Manual BHT-BASIC Programmer's Manual (BHT-100 series) iii
ページ6に含まれる内容の要旨
SAFETY PRECAUTIONS Be sure to observe all these safety precautions. Strict observance of these warning and caution indications are a MUST for preventing accidents which could result in bodily injury and substantial property damage. Make sure you fully understand all definitions of these terms and related symbols given be- low, before you proceed on to the text itself. Alerts you to those conditions which could cause serious bodily injury or death if the instructions are not followed WARNING cor
ページ7に含まれる内容の要旨
WARNING • Avoid dropping the battery cartridge or letting it undergo any shock or impact. Doing so could cause the batteries to break, generate heat, rupture or burn. Charge only • Only use the dedicated charger (CU-7011, with the dedicated CU-7001, C-700 or C-750) for charging the device. battery cartridge. Using a different type of charger could cause battery-rupture or leakage of battery fluid and result in a fire, bodily injury, or se- rious damage to property. Undedicated • Never charge the
ページ8に含まれる内容の要旨
CAUTION Handling the battery cartridge • Never charge a wet or damp battery cartridge. Doing so could cause the batteries to break, generate heat, rupture, or burn. I'm burning Handling the CU up! • Never put the CU in places where there are excessively high temperatures, such as inside closed-up automobiles, or in places exposed to direct sunlight. Doing so could affect the housing or parts, resulting in a fire. • Avoid using the CU in extremely humid or dusty areas, or where there are drastic
ページ9に含まれる内容の要旨
■ Proper Care of the CU Before starting cleaning, unplug the AC adapter from the wall socket for safety. Clean the housing and the charge terminals of the CU and the battery cartridge termi- nals with a dry, soft cloth. • Never use benzene, alcohol, or other organic sol- Take care of me vents. The housing may be marred or the paint may with a dry soft cloth. come off. • If the CU becomes smudged, moisten a soft cloth NO WAY!! with neutral detergent and wring it out thoroughly. Wipe the CU with
ページ10に含まれる内容の要旨
Content Overviews Preface................................................................................................................................. i How this book is organized .............................................................................................. ii SAFETY PRECAUTIONS..................................................................................................... iv Chapter 1 Ethernet System Configuration .......................................................
ページ11に含まれる内容の要旨
Chapter 1 Ethernet System Configu- ration Connecting CU-7011 units to an Ethernet enables you to use BHTs as a LAN client. BHT • FTP • Socket API Host computer • TCP/IP Optical communication CU-7011 • Protocol exchange between optical communication and Ethernet • MAC address Ethernet 10Base-T BHT Optical communication CU-7011 For details about FTP and Socket API, refer to the BHT-BASIC Programmer's Manual. For procedures about setting the TCP/IP and FTP on the BHT, refer to the BHT User's Manual
ページ12に含まれる内容の要旨
Chapter 3 Components and Functions LED indicators DATA (Communications LED, green) Lights when the BHT is communicating with the host computer. POWER (Power LED, green) Lights when the power is applied to the CU-7011. Optical interface port Used to exchange data optically BHT charge terminals with the BHT. Do not stain these terminals; failure to protect the terminals may result in decreased charging efficiency.) CU-7011 Ethernet interface port (10Base-T) Used to connect to an Ethernet. Power
ページ13に含まれる内容の要旨
Chapter 4 CU Status Indication by LED Indicators According to the ON/OFF states of the POWER and DATA LED indicators, you may check the machine status of the CU-7011 as listed below. POWER DATA Machine status OFF OFF Power off ON OFF Power on ON ON Communicating with the host 1 Flashing slowly* ON Updating the CU system program 2 Flashing slowly Flashing* Waiting for retry after occurrence of a CU system program updating error Flashing slowly Flashing slowly System program failure Solution: Cont
ページ14に含まれる内容の要旨
Chapter 5 Applying Power to the CU-7011 Apply power to the CU-7011 via the dedicated AC adapter. Connect the outlet plug of the AC adapter to the power inlet connector of the CU-7011, then plug the other end of the AC adapter into a wall socket. AC adapter Power inlet connector • If smoke, abnormal odors or noises come from the CU, WARNING immediately unplug the AC adapter from the wall socket and contact your nearest dealer. Failure to do so could cause fire or electrical shock. • If foreign ma
ページ15に含まれる内容の要旨
Chapter 6 Connecting to Ethernet 6.1 Setting the Transmission Speed of the CU-7011 Set the transmission speed of the CU-7011 to the same value as that of the BHT, by using the DIP switch provided on the bottom of the CU-7011. (1) Unplug the AC adapter from the wall socket. (2) Turn the CU-7011 upside down. (3) Remove the protection sheet of the DIP switch from the CU-7011. (4) Set the selectors of the DIP switch as shown below. For 115.2k bps O N ON OFF ON 1 2 3 1 23 For 4M bps DIP switch O
ページ16に含まれる内容の要旨
6.2 Interface Cable Connection Connect the modular plug* of the Ethernet cable to the Ethernet port of the CU-7011. (*10Base-T 8-pin modular, RJ45, ITA/ETA category 3 or higher) Lock lever Ethernet cable •When connecting the modular plug, insert it until it snaps into place. To disconnect it, press the lock lever and pull it out. • Do not force the modular plug in or out. Doing so will result in a CU-7011 failure. 6
ページ17に含まれる内容の要旨
6.3 Communication with the Host Computer This section describes how to start communication with the host computer according to the FTP in System Mode. (1) Turn on the host computer. (2) On the host computer, start the FTP server program. (3) Turn on the BHT and run System Mode. Set the TCP/IP parameters (incl. IP address and subnet mask)) and FTP parameters (incl. server IP and user ID). (4) Put the BHT on the CU-7011. BHT CU-7011 Take care not to put the hand strap or get any foreign material b
ページ18に含まれる内容の要旨
Chapter 7 Charging the Rechargeable Battery Cartridge You may charge the battery cartridge loaded in the BHT. Service Life of Rechargeable Battery Cartridge: Lithium-ion batteries used in the battery cartridge will gradually deteriorate during the repeated cycles of charging and discharging due to its properties, even under normal use. When the battery run time becomes shortened due to its deterioration even if it has been charged for the specified hours, replace the battery cartridge with a ne
ページ19に含まれる内容の要旨
■ Charging Operation and BHT's Indicator LED Indicator LED on Operator's Action CU-7011 Status the BHT On standby OFF ⇓ Place the BHT Normal charging ON on the CU-7011. (in red) ⇓ ⇓ After approx. 6 hours Charging completed ON (in green) ⇓ ⇓ Remove the BHT. On standby OFF The charging time is approx. 6 hours if the "Charge the battery!" message is displayed on the BHT. The battery cartridge not discharged so much will be fully recharged in shorter time. 9
ページ20に含まれる内容の要旨
Chapter 8 Displaying the CU System Information on the BHT You may display the CU-7011 system information on the BHT's LCD. Set the BHT on the CU-7011 and operate the BHT to display the SYSTEM INFORMA- TION screen on the LCD. From that screen, you may call up the system program version and MAC address. For details about the displaying procedure of the CU system information, refer to the BHT User's Manual, "LAN Support Version." Chapter 9 Updating the CU System Program via the BHT You may update t