ページ1に含まれる内容の要旨
Installation
Instructions
8871
LEXINGTON Spread Lavatory
Faucet with the Speed Connect™ Drain
Congratulations on purchasing your American Standard faucet
with the Speed Connect drain, a feature found only on
American Standard faucets.
Speed Connect™ Drain* Certified to comply with ANSI A112.18.1
M966230 Rev. 1.2
� Fewer parts, installs in less time
� Never needs adjustment
� Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only wit
ページ2に含まれる内容の要旨
POP-UP DRAIN 2 Fig. A. Fig. B. Remove CLEAR PLASTIC COVER (1). 1 Remove CARDBOARD SPACER (2) from under DRAIN DRAIN POP-UP (3). 3 BODY Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig. B. 2 4 REMOVE FLANGE Fig. A. Fig. B. 3 1 Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body. Fig. A. Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3). Fig. B. 4 2 3 INSTALL DRAIN FROM TIGHTEN LOCKNUT 4 RE
ページ3に含まれる内容の要旨
ATTACH CABLE CONNECTOR 7 Fig. A. Fig. B. Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and 1 hand tighten. Fig. A. Your new POP-UP DRAIN installation is now complete. Fig. B. Note: Tailpeice on pop-up drain is 1-1/4” O.D. Fig. B. 2 1-1/4” O.D. CHECK OPERATION OF POP-UP 8 1 Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes. Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions. 2 MAKE WATER SUP
ページ4に含まれる内容の要旨
INSTALL HANDLES 10 Turn off hot and cold water CAUTION supplies before beginning. See separate instruction sheet supplied with handle kit for handle installation. TEST INSTALLED FITTING 11 5 With VALVE (1) in OFF position, turn on WATER 1 SUPPLIES (2) and check all connections for leaks. Remove AERATOR (3). 1 Operate both HANDLES (1) to flush water lines thoroughly. 3 Replace AERATOR (3). CHECK DRAIN CONNECTIONS 12 4 Operate POP-UP KNOB (5) and fill Sink with water. Check that DRAIN STOPPER (4) m
ページ5に含まれる内容の要旨
Speed Connect™ Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the “down” position: • Follow CABLE ADJUSTMENT PROCEDURE. If Stopper does not raise up fully or sink drains too slowly: • Follow CABLE ADJUSTMENT PROCEDURE. If you need to remove the Stopper: • Follow STOPPER REMOVAL PROCEDURE. If you would like the ability to remove your Stopper simply by lifting it out of the drain: • Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode. C
ページ6に含まれる内容の要旨
STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable). Locked Mode: Look at the Plastic Loop at the bottom of the Stopper and notice Fig. G. that the Loop is on one side of the Stopper. Fig. G. To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the LOGO Sink and the American Standard logo is facing front. Rotate Stopper s