ページ1に含まれる内容の要旨
VF03
ページ2に含まれる内容の要旨
Dear Customer, ® Thank you for purchasing the Verilux Heritage™ Deluxe Full Spectrum Floor Lamp. You have received a quality product, ® backed by a three-year limited warranty. As a Verilux customer, your satisfaction means everything to us. We look forward to serving you now and in the future. Many other healthy lighting products are available through our catalog and online. Please visit us on the web at ® www.Verilux.com to learn about other great Verilux products. Have a Bright Day! Nic
ページ3に含まれる内容の要旨
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS ® Thank you for purchasing the Heritage™ Natural Spectrum Deluxe Floor Lamp. Please read the following safety information before using. To reduce the risk of fi re, electrical shock, or injury to persons: • Do NOT dismantle. • Do NOT alter power cord. • Turn off/unplug and allow to cool before replacing bulb or cleaning. • For indoor use only. • The lamp is an electrical device. DO NOT USE NEAR WATER GENERAL PRECAUTIONS • Before plugging in
ページ4に含まれる内容の要旨
GETTING STARTED Main Parts & Controls ® A. Optix Glare Control Filter G. Lower Shaft B. Switch H. Lamp Base C. Lamp Head Swivel Knob I. Power Cord D. Lamp Arm J. Power Supply (Ballast) E. Height Adjusting Collar K. Bulb F. Upper Shaft D Close-up of Lamp Head A C B E K F B A G I H J Attention! Lift your lamp by the vertical shaft, NOT the lamp arm. 4
ページ5に含まれる内容の要旨
ASSEMBLY INSTRUCTIONS Please Read Operating Instructions Carefully Before Using the Heritage™ Full Spectrum Floor Lamp: 1. Set lamp base on the fl oor and insert the D lower lamp shaft (G) onto the base and screw clockwise to tighten. (Fig.1) E 2. Pull the slack of the electrical cord through the lamp base. (I) 3. Loosen the height adjusting collar (E) to F free lamp arm. (D) 4. With one hand holding the lamp arm (D), screw the upper shaft (F) onto the lower shaft. (G) (See Assembly Detai
ページ6に含まれる内容の要旨
ASSEMBLY INSTRUCTIONS cont. ® 7. Attaching the Optix glare control fi lter: • Remove glare control fi lter from protective plastic bag. Take care to hold fi lter by the edges only. • Insert tabs on bottom of fi lter into opening. (Fig. 2) • Press into place using thumb tab. Note: Do not Do not touch or press touch material on the fi lter material itself. Fig. 2 8. Attach the ballast to the power cord. Use care to align the 4-pin plug properly. DO NOT FORCE – the 4-pin plug was designed to
ページ7に含まれる内容の要旨
ADJUSTING THE HERITAGE™ FLOOR LAMP The Heritage™ Floor Lamp D adjusts several ways: 1. To adjust lamp height – hold upper Height shaft (F) with one hand, loosen height adjusting adjusting collar. Raise or lower lamp collar arm (D) to desired height. Tighten collar. (Fig. 5) F Note: Do not stand on cord or otherwise restrict its movement while raising or Fig.5 lowering the height of the lamp. 2. To rotate the lamp head right or left, loosen height adjusting collar, swing lamp arm to des
ページ8に含まれる内容の要旨
BULB REPLACEMENT INSTRUCTIONS Removal C D 1. Unplug lamp from power source. ® 2. To access the bulb, remove Optix glare control fi lter by depressing the thumb tab and lifting it out. 3. Firmly hold bulb base (B) and pull bulb (C) from the socket (A) in an B outward motion. (Fig. 9) Installation 1. Unplug lamp from power source. A 2. Firmly hold base (B) and push bulb (C) into the socket (A). Fig. 9 3. Be sure bulb is fi rmly seated in the socket (see below) and snapped into the metal bulb
ページ9に含まれる内容の要旨
TROUBLESHOOTING ® Your Verilux desk lamp uses advanced micro-electronics to power the revolutionary Trucolite™ bulb. These electronics are housed in a specially designed ballast located at the power plug. The LED indicator light on the ballast allows you to troubleshoot any problems with the ® lamp’s function. When replacing your Verilux ballast, take care to plug in the power cord properly. The 4-pin plug was designed to fi t in only one orientation (See Assembly Instructions on page 5). •
ページ10に含まれる内容の要旨
CARE & CLEANING Your lamp is made from high quality materials that will last for many years with minimum care. You may want to periodically clean the lamp, using a mild non-abrasive cleaner and soft cloth. When cleaning, make sure you have turned off and unplugged the unit, and allowed suffi cient time for the unit to cool. All liquid should be properly wiped away and dried prior to restoring power. DO NOT USE SOLVENTS OR CLEANERS CONTAINING ABRASIVES, OR AMMONIA BASED CLEANERS Note: Do not
ページ11に含まれる内容の要旨
WARRANTY Three-Year Limited Warranty ATTENTION! ONCE OPENED, PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE WHERE IT WAS PURCHASED FOR REPAIR OR REPLACEMENT! Many questions may be answered by visiting www.Verilux.com, or you may call our customer service department at 1-888-544-4865. This limited warranty is provided by: Verilux, Inc., 340 Mad River Park, Waitsfi eld, VT 05673 ® Verilux warrants this product to be free from defects in material and workmanship for a period of three years from t
ページ12に含まれる内容の要旨
Please visit our web site at: www.Verilux.com 340 Mad River Park, Waitsfi eld, VT 05673 1-888-544-4865 Printed in Taiwan for Verilux, Inc. VF03-MAN-Rev3 © Copyright 2007 Verilux, Inc. All rights reserved.