ページ1に含まれる内容の要旨
®
PowerCharger
DUAL and QUAD
2400 and 2700 series
OWNER’S MANUAL
ページ2に含まれる内容の要旨
TABLE OF CONTENTS INTRODUCTION .............................................................................................1 STANDARD FEATURES.................................................................................1 EXPANSION OPTIONS ..................................................................................2 SAFEGUARDS................................................................................................3 GROUNDING/EARTHING...................................
ページ3に含まれる内容の要旨
INTRODUCTION This Anton/Bauer InterActive 2000 PowerCharger represents over 25 years of Anton/Bauer technology and experience in a totally new portable power system. The technology advancements of this new combination, charger/camera power supply, delivers the features and performance of several essential power products in one economical package. Fully compatible with all current and future Anton/Bauer Logic Series Gold Mount batteries, the InterActive 2000 system is a totally new modul
ページ4に含まれる内容の要旨
EXPANSION OPTIONS The exclusive modular design of the new Anton/Bauer InterActive 2000 PowerCharger provides ultimate flexibility for all video operations. Starting with any base model, a wide range of expansion modules and upgrades can be added: diagnostic/discharge functions, charge position expansion, and power supply modules. All this is as easy as installing a memory or peripheral addition to a computer. • Diagnostic/discharge module (DDM) featuring automatic calibration of DIGIT
ページ5に含まれる内容の要旨
SAFEGUARDS Power Sources: This unit was designed to operate at mains voltages from 90 to 250 Volts AC, 50-60 Hz. Risk of Electrical Shock: Refer servicing to qualified service personnel. TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. GROUNDING/EARTHING IMPORTANT WARNING: THIS APPARATUS MUST BE EARTHED. To ensure safe operation, the three pin plug supplied must be inserted only into a standard three-pin power point which is effectively grounded through th
ページ6に含まれる内容の要旨
Software revision, power rating, and model number can be obtained from the Signature Display. When the LCD shows the main display screen, press the TEST button on the front panel. Charging As with all Anton/Bauer chargers, charging with an InterActive 2000 PowerCharger is fully automatic. Mount any applicable battery to any open Gold Mount position on the charger or charge expansion module and the PowerCharger will automatically determine the appropriate charge routine and execute it.
ページ7に含まれる内容の要旨
Three Stage Charging Methodology In general, the PowerCharger will deliver a three stage charge routine to each battery. 1. Stage One will deliver a high rate charge matched to the capabilities of the battery (typically a one or two hour rate, depending on battery type and charger power module rating). During this stage, six separate cutoff methods are in operation, simultaneously, ensuring the fastest, safest charge for that battery. Stage One is indicated by the LCD displaying “Cha
ページ8に含まれる内容の要旨
NOTE: Anton/Bauer strongly recommends that batteries are kept on the PowerCharger until ready for use. The Lifesaver mode will keep them 100% charged and ready for use. LCD Indications Each PowerCharger’s liquid crystal display (LCD) will display the status of each battery, as well as, important PowerCharger operating indications. The following information explains the indications which appear in the LCD. The levels of the LCD display on each PowerCharger can be obtained by pressing
ページ9に含まれる内容の要旨
LED Indications Each charge position of a PowerCharger and PowerCharger Charge Module (XM models) has a pair of LEDs (one red, one green) which indicate the status of the battery attached to that position. The following table identifies all of the PowerCharger LED indications and their meaning: LED INDICATION MEANING Alternating Indicates that the PowerCharger is evaluating the battery and/or Red & Green communicating with a DIGITAL battery, loading battery parameters and determinin
ページ10に含まれる内容の要旨
Priority Battery Function A unique operating feature of all PowerChargers allows the operator to select any battery on any charge position as a PRIORITY BATTERY. While connecting a battery to any charge position, hold the DISPLAY button until an audible indication sounds and the LCD indicates: PRIORITY BATTERY The PowerCharger will interrupt the charging of any other battery and address the Priority Battery immediately (assuming it is within a safe charging parameters). When prio
ページ11に含まれる内容の要旨
The standard test is adequate for virtually all conditions to verify the capacity of the battery before taking it into the field. The 24 hour test need only be performed on a battery, typically an older one (2 years or more), which may have exhibited questionable performance. Note: The DDM test mode should be used sparingly. Remember that a cycle performed in test is part of the battery’s overall life. Anton/Bauer suggests that a typical management routine for your batteries might be
ページ12に含まれる内容の要旨
When testing is completed, the LCD Main Display will indicate “TEST DONE”. To display or print test results: 1. Press the DISPLAY button on the PowerCharger front panel to scroll to the Primary Position Display for the battery tested. 2. Press the TEST button. The LCD will display the capacity of the battery in ampere hours. If a printer is attached, performance data will simultaneously be printed out with all battery identification information. Consult your battery owners manual fo
ページ13に含まれる内容の要旨
XM CHARGE EXPANSION MODULE The “XM” charge expansion modules easily attach to any model PowerCharger via the 9- pin D-shell computer style connector marked “CHARGE MODULE ACCESSORY”. These economical modules automatically expand the PowerCharger’s charging capabilities with additional positions. The XM-2002 or XM-2004 modules allow the charging of two or four additional Logic Series batteries. The XM NP/90 module will charge any combination of up to four NP or 90 style batteries. The
ページ14に含まれる内容の要旨
POWER LOSS MEMORY MODE The PowerCharger features a special Power Loss Memory or “Power Down” mode. When mains power is interrupted while batteries are mounted, the PowerCharger will automatically indicate the charge status of all batteries until power is restored (up to 16 hours). When power is interrupted, an audible alert will be heard every 30 seconds for 30 minutes to notify the operator if power has been inadvertently removed. The LCD will display the message “POWER DOWN MODE” al
ページ15に含まれる内容の要旨
WARRANTY IMPORTANT: PLEASE MAIL WARRANTY REGISTRATION CARD WITHIN TEN (10) DAYS OF PURCHASE. We must have this card on file at our SERVICE DEPARTMENT to establish this warranty. Proper registration will also enable us to provide update information on the InterActive 2000 PowerCharger battery system. All new Anton/Bauer products have been thoroughly tested and inspected prior to shipment. This product is warranted against defect in materials and workmanship for a period of three (3)
ページ16に含まれる内容の要旨
® The worldwide standard ® sm The power behind the best cameras capturing the best images in the world. The following are trademarks of Anton/Bauer, Inc.: ACS, ADM, Anton/Bauer, Anton/Bauer logo and parallelogram design, Aspekt, Automatique, DataTap, Dionic, ElipZ, ElightZ, EgripZ, Gold Mount, HyTRON, Impac, InterActive and design, LifeSaver, Logic Series, Logic Series logo, Maxx man logo design, MicroCode, PowerStrap, Probe, Proformer, ProPac, RealTime, SSP, Satel