ページ1に含まれる内容の要旨
Installation and Assembly:
Peerless Ultra-Slim Articulating Mount for Samsung 46"
and 55" C9000 LED displays
Models: SUAC9000
U
C © L US
Max UL Load Capacity: 75 lb (34 kg)
3215 W. North Ave. • Melrose Park, IL • (800) 865-2112 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessmounts.com
ISSUED: 10-01-10 SHEET #: 095-9354-3 12-13-10
ページ2に含まれる内容の要旨
NOTE: Read entire instruction sheet before you start installation and assembly. WARNING • Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact your local distributor. • This product should only be installed b
ページ3に含まれる内容の要旨
Before you begin, make sure all parts shown are included with your product. Parts List Description Qty. Part # A wall arm assembly 1 046-4176 B upper mounting plate 1 046-4179 C lower mounting plate 1 046-4180 D wood screw 4 500-1090 E concrete anchor 4 590-0320 F security driver 1 560-1133 G fastener cap 8 046-4096 H cable clip 1 046-4137 I short cable tie 3 560-2004 J snap caps 4 560-2029 A K 10-32 x 1/2" thread forming screw 4 520-2627 L 1/4-20 x 1/2" hex head thread forming 4 520-2592 screw
ページ4に含まれる内容の要旨
Installation to Wood Stud Wall WARNING • Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components. • Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power. • Never tighten in excess of 80 in. • lb (9 N.M.). • Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to
ページ5に含まれる内容の要旨
Installation to Solid Concrete or Cinder Block WARNING • When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to
ページ6に含まれる内容の要旨
WARNING • Be sure to carry display upright, from the top and bottom edges, or damage to display may occur. Follow instruction manual included with display to remove display from stand. 2 Set display on a fl at, level surface. Refer to display manufacturer's installation guide for recommended careful handling. Remove two M4 chrome plated screws from Ultra-Slim wall mount bar. Save all screws. Install eight standoff screws (included with display) into eight mounting holes on bottom of display. M5
ページ7に含まれる内容の要旨
Set control box into lower mount plate (C) and place assembly onto back of display. Adjust upper and lower 4 mounting plates (B,C) to align top mounting holes with ultra-slim wall mount bar. Secure assembly to back of display by reinstalling two M4 chrome plated screws (included with display) into ultra- slim wall mount bar, four M4 black phillips screws (included with display) into lower mounting holes of control box, and four M4 x 16 mm phillips screws (M) into upper mounting holes of contro
ページ8に含まれる内容の要旨
Mounting Flat Panel Screen WARNING • Tighten screws so screen brackets are fi rmly attached to screen. Do not tighten with excessive force. Overtightening can cause stress damage to screws, greatly reducing their holding power and possibly causing screw heads to become detached. Tighten to 40 in. • lb (4.5 N.M.) maximum torque. Hook two 1/4-20 x 1/2" thread forming screws (L) onto top slots of front plate as shown in fi gure 6.1. 6 Fasten two 1/4-20 x 1/2" thread forming screws (L) into bottom m
ページ9に含まれる内容の要旨
Cable Management Cables may be routed using short cable ties (I). 7 Use holes on bottom of lower mounting plate (C) with cable ties (I) to secure cables as shown below. I CABLES Cables may be routed using cable clip (H). Slip cable clip (H) onto bottom of center joint as shown in fi gure 7.1 and secure cables to cable clip using long cable tie (N) as shown in fi gure 7.2. Secure cables to bottom of wall plate using cable tie (N) as shown below. WALL PLATE SLOTS N CENTER CABLES JOINT N CABLES H
ページ10に含まれる内容の要旨
Roll Adjustment Adapter plate may be rolled +/- 5°. 8 Loosen four M6 nylock nuts half a turn, grasp edges of display and roll screen to desired position as shown. Retighten four M6 nylock nuts and place four snap caps (J) onto M6 nylock nuts. CAUTION • Do not tighten joint screws. Doing so may cause damage to screws, greatly reducing its holding power. JOINT SCREWS M6 NYLOCK NUTS ISSUED: 10-01-10 SHEET #: 095-9354-3 12-13-10 10 of 10 © 2009, Peerless Industries, Inc. All rights reserved.