ページ1に含まれる内容の要旨
HRFG - ER*A HRFG - SR*A HRFG - SER*A
Halsey Taylor Owners Manual
Refrigerated Marblyte Fountains with Back Panel
HRFG - ER HRFG - SR HRFG - SER
Installer
To assure you install this model easily and correctly, PLEASE
READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING
THE INSTALLATION. CHECK YOUR INSTALLATION FOR
COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER
APPLICABLE CODES. After installation, leave these instruc-
tions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFO
ページ2に含まれる内容の要旨
HRFG - ER*A HRFG - SR*A HRFG - SER*A HRFG-ER/SR ROUGH-IN FINISHED FLOOR LEGEND: A = 3/8" O.D. TUBE WATER OUTLET B = 3/8" O.D. TUBE WATER INLET C = 1-1/4" O.D. WASTE TUBE (NOT INCLUDED) FIG. 1 97716C (Rev. A - 5/02) PAGE 2
ページ3に含まれる内容の要旨
HRFG - ER*A HRFG - SR*A HRFG - SER*A HRFG-SER ROUGH-IN FINISHED FLOOR LEGEND: A = 3/8" O.D. TUBE WATER OUTLET B = 3/8" O.D. TUBE WATER INLET C = 1-1/4" O.D. WASTE TUBE (NOT INCLUDED) FIG. 2 97716C (Rev. A - 5/02) PAGE 3
ページ4に含まれる内容の要旨
HRFG - ER*A HRFG - SR*A HRFG - SER*A INSTALLATION INSTRUCTIONS 1. Install remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from be tween compressor and side panel. Slide chiller onto the shelf and position it to the left within the guides on the shelf. NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller. A minimum of 4" (102mm) on both sides and top is required. See chiller instructio
ページ5に含まれる内容の要旨
HRFG - ER*A HRFG - SR*A HRFG - SER*A 3/8" O.D. UNPLATED COPPER TUBE CONNECT 1/4" O.D. TUBE COLD WATER SUPPLY WATER INLET BUILDING WATER INLET TO COOLER NOTE: WATER FLOW SERVICE STOP DIRECTION (NOT FURNISHED) FIG. 3 OPERATION OF QUICK CONNECT FITTINGS TUBE IS SECURED SIMPLY PUSH IN PUSH IN COLLET IN POSITION TO RELEASE TUBE TUBE TO ATTACH PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE FIG. 4 FIG. 5 PAGE 5 97716C (Rev. A - 5/02)
ページ6に含まれる内容の要旨
HRFG - ER*A HRFG - SR*A HRFG - SER*A 9 7 6 2 13 5 10 BASIN 26 16 FIG. 6 TOP VIEW 23 8 15 SEE FIG. 5 3, 4 1 18 24 25 SEE FIG. 6 19 12 11, 14, 17 FIG. 7 97716C (Rev. A - 5/02) PAGE 6
ページ7に含まれる内容の要旨
HRFG - ER*A HRFG - SR*A HRFG - SER*A FIG. 8 FIG. 9 PAGE 7 97716C (Rev. A - 5/02) TO BUBBLER TO BUBBLER TO BUBBLER 12 12 21 22 20 CHILLER OUTLET 20 CHILLER OUTLET CHILLER INLET CHILLER INLET HRFG - ER / SR HRFG - SER TUBE ROUTING TUBE ROUTING
ページ8に含まれる内容の要旨
HRFG - ER*A HRFG - SR*A HRFG - SER*A PARTS LIST ITEM NO. PART NO. DESCRIPTION 1 Drain LK464 2 15005C Retaining Nut 3 40038C Strainer 4 40619C Tailpipe Ferrule 5 45662C Push Button 6 Push Button Sleeve 45738C 7 50986C Regulator Holder 8 51544C Bubbler 9 61313C Regulator 10 70022C Setscrew #6-32 x .31" 11 Scr, #10-24 x 1/2 PH TR HD-Z 112627543890 12 55996C Strainer 13 56087C Push Button - Extension 14 27201C Bottom Cover Plate-Short 27658C Bottom Cover Plate-Extended 15 Back Panel HRF-SER 2683