ページ1に含まれる内容の要旨
EPL Envoy
Parking Luminaire
Sheet 1 of 5
INSTALLATION INSTRUCTIONS
8/20/08 IMI-694
IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE
GENERAL: Upon receipt of luminaire thoroughly inspect for any freight WARNING: Make certain power is OFF before starting installation or
damage, which should be brought to the attention of the delivery attempting any maintenance.
carrier. Compare the catalog description listed on the packing slip WARNING: Risk of Electric Shock. Dis
ページ2に含まれる内容の要旨
PUSH EPL Envoy Parking Luminaire Sheet 2 of 5 INSTALLATION INSTRUCTIONS 8/20/08 IMI-694 IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE 5. Lift up luminaire onto the (4) four hooks of quick mount plate while guiding Figure 4 the wires through center access hole (Figure 3). 6. Push luminaire forward for engagement (Figure 3). When it reaches the TAMPER-PROOF SCREW FOR LATCH full-engaged position, a “CLICK” can be heard. CAUTION: If full engagement is not reach
ページ3に含まれる内容の要旨
EPL Envoy Parking Luminaire Sheet 3 of 5 INSTALLATION INSTRUCTIONS 8/20/08 IMI-694 IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE LAMP INSTALLATION: : Figure 8 1. To install the lamp, unlatch both latches (Figure 6). Note: Remove tamper proof screws first if luminaire includes (TR) tamper-resistant option (Figure 4). 2. Allow lens to swing open (Figure 7). Lens will remain captive. CAUTION: Support lens while it swings open. 3. Install lamp securely into sock
ページ4に含まれる内容の要旨
EPL Envoy Parking Luminaire Sheet 4 of 5 INSTALLATION INSTRUCTIONS 8/20/08 IMI-694 IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE TRUNNION MOUNT INSTALLATION: (Figure 11) Figure 11 CONDULET Note: Use minimum 90°C supply wire when installed per below procedure 3/8” BOLT BODY and connections are made inside of condulet body. TOP Note: For 8-3/8” to 13-1/4” vertical adjustment (Up or Down only). TRUNNION COVER 1. Install top trunnion on the
ページ5に含まれる内容の要旨
EPL Envoy Parking Luminaire Sheet 5 of 5 INSTALLATION INSTRUCTIONS 8/20/08 IMI-694 IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE THRU-BRANCH WIRING INSTALLATION: (Figure 13 & 14) Figure 13 #10-24 X 5/8 TAPTITE NOTE : Use 90°C wire rating for luminaire with thru-branch option for SCREW (BY OTHERS) KNOCK-OUT fixtures 100w or below at 25°C ambient temperature applications. WIRE TIE FEATURE : Use 105°C wire rating for luminaire with thru-branch option for (BY O