ページ3に含まれる内容の要旨
Starck Starck X 10101XX1/10106XX1/10140XX1/10145XX1 10170001/10175001/10180001/10185001 Do not install this faucet on a sink with a raised lip. ok! no! Technical Information Recommended water pressure 15 - 58 psi Max. water pressure 58 psi o Max. hot water temp. 176 F* o o Recommended hot water temp. 10 F - 140 F* Flow rate 1. gpm Battery CR-P / 6 V Lithium Automatic shutoff after 1 minute *Please know and follow all local plumbing codes when setting the temperature on the water heat
ページ4に含まれる内容の要旨
Installation notes • Flush the hot and cold supplies thoroughly • The distance between the switch on/off before installing the faucet. Damage to point to the faucet is approx. 6 1/4” - 8” the faucet caused by debris is not covered under normal conditions. The detection under the warranty. area may be less for dark, non-reflective objects, or greater for bright, highly reflec- • The hot and cold supplies should be of tive objects. equal pressure. • If the sink is very small or highly • Th
ページ5に含まれる内容の要旨
Installation Position the faucet on the sink or countertop (1). Install and tighten the mounting nut (). Tighten the tensioning screws (). Connect the /8” adapters to the stops (4). Connect the hoses to the adapters (5). Tighten the hoses with two wrenches, as shown, to prevent the hoses from twisting. 5
ページ6に含まれる内容の要旨
Connect the faucet power cable to the battery pack or AC power pack (1). Plug the AC power pack in. Turn the hot and cold supplies on (). Remove the protective film from the sensor window (). Wait 0 seconds before attempting to use the faucet (4). Position your hand in front of the sensor to turn the water on. Due to air in the faucet, the spray pattern may be unattractive for the first 10 - 15 uses after installation or service. Models with manual temperature adjustment only: p
ページ7に含まれる内容の要旨
Remove the faucet body (1). Turn the temperature screw forward to make the water cooler, backward to make it warmer (). Dry any drops of water from the faucet or mounting surface. Replace the faucet body (1). Replace the screw (). Turn the water supplies on (). Reconnect the power cable (4). Wait 30 seconds (1). Place your hand in front of the faucet to turn it on (). 7
ページ8に含まれる内容の要旨
Battery Replacement -- models 10101XX1/ 10106XX1/10170001/10175001 only If the LED in the sensor window flashes, the battery is low, but the faucet can still be used. If the LED lights continuously, the battery must be changed before the faucet can be used. Remove the four screws and the battery pack cover. Remove the old battery (1). Install the new battery (). Reinstall the battery pack cover. Wait 30 seconds (1). Activate the faucet by placing a hand in front of the sensor (). 8
ページ9に含まれる内容の要旨
Clean the aerator and filters -- all models If the water flow is reduced over time, clean the aerator (a) and the filters (b). Turn the water supplies off (1). Disconnect the power cable (). Starck 10101/10106/10140/10145 -- unscrew and remove the aerator (a). Starck X 10170/10175/10180/10185 -- remove the spray former (a), using a mm Allen wrench to loosen the screws. Do not lose the screws! All models -- disconnect the hot and cold supply hoses from the adapters. Remove the filters
ページ10に含まれる内容の要旨
Turn the water on (1). Reconnect the power cable (). Wait 30 seconds (1). Place a hand in front of the sensor to turn the faucet on (). 10
ページ11に含まれる内容の要旨
Cleaning The faucet may be turned off temporarily so that the sink may be cleaned. Cover the sensor window with a hand for approximately 10 seconds. The faucet will turn off for approximately 60 seconds, so that the sink may be cleaned. The LED in the sensor window will flash. When the LED no longer flashes, the faucet may be used normally. 11
ページ12に含まれる内容の要旨
Change the Spray Former -- Starck X 10170 / 10175 / 10180 / 10185 only The waterfall spray former is installed on the faucet at the fac- tory. A round monospray spray former is included with the faucet. The spray former may be changed easily, if desired. Use a mm Allen wrench to remove the spray former screws. Remove the old spray former. Install the new spray former. Tighten the screws. 1
ページ13に含まれる内容の要旨
Reduce the Sensor Range The sensor is set for maximum range at the factory. If the faucet is used on a very small or highly reflective lavatory, the sensor range may be reduced by ap- proximately ”. Disconnect the power cable for approximately 10 seconds (1). Reconnect the power cable (). The LED will blink once to indicate that it is in the “maximum range” mode. When the LED stays on, cover the sensor window with your hand or with a white card for 0 - 40 seconds to reset the electron
ページ14に含まれる内容の要旨
Replacement Parts 4 6 1 10 5 8 7 1 battery, lithium CR-P / 6V XX = color connection hose 880 000 00 = chrome spray former 8867000 80 = Steel 4 aerator, Starck 4005XX0 5 fixing set 161000 6 electronics, Starck 87 000 electronics, Starck X 884000 7 AC adapter 8 battery box 8801000 Maintenance note: the check valves (item #) check valve 6456000 should be removed and checked yearly. 10 aerator, Starck X 8610000 14
ページ15に含まれる内容の要旨
Cleaning Recommendation for Hansgrohe Products Modern lavatory faucets, kitchen faucets, and showers consist of very different materials to comply with the needs of the market with regard to design and functionality. To avoid damage and returns, it is necessary to consider certain criteria when cleaning. Cleaning Materials for Faucets and Showers Acids are a necessary ingredient of cleaning materials for removing lime, however please pay attention to the following points when cleaning faucet
ページ16に含まれる内容の要旨
including, without limitation, a commercial purpose, this warranty extends only (i) for 1 year, with respect to Hansgrohe and Commercial products, and (ii) for 5 years, with respect to AXOR products. THIS WARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT PAY FOR: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B. Conditions, malfunctions or damage resulting from (1) normal wear and tear, improper installation, improper maintenance, misuse, abuse, ne