ページ1に含まれる内容の要旨
ページ2に含まれる内容の要旨
DS4300 INSTALLATION MANUAL
ページ3に含まれる内容の要旨
We DATALOGIC S.p.A. Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy declare under our sole responsibility that the product DS4300-XXXX, Laser Scanner and all its models to which this declaration relates is in conformity with the following standards or other normative documents EN 55022, August 1994:LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT (ITE) EN 50082-2, March 1995:ELECTROMAGNETIC COMPATIBILITY. GENERIC IMMUNITY STAND
ページ4に含まれる内容の要旨
CONTENTS GUIDE TO INSTALLATION...............................................................v General View ..................................................................................... vi SAFETY PRECAUTIONS ................................................................viii Laser Safety......................................................................................viii Standard Regulations .......................................................................viii Power Supply...
ページ5に含まれる内容の要旨
3 READING FEATURES....................................................................3.1 3.1 Advanced Code Reconstruction ......................................................3.1 3.1.1 Tilt Angle for Advanced Code Reconstruction.................................3.2 3.2 Decoding Capacity in Linear Mode..................................................3.3 3.2.1 Step Ladder Mode ...........................................................................3.3 3.2.2 Picket Fence Mode..................
ページ6に含まれる内容の要旨
GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessary for complete installation of the DS4300 scanner. 1) Read all information in the section "Safety Precautions" at the beginning of this manual. 2) Correctly position and mount the scanner for barcode reading according to the information in paragraphs 2.2, 2.5 and 3.4. 3) Provide correct system cabling according to the signals necessary for your application (see the applicable sub-paragraphs under 2.
ページ7に含まれる内容の要旨
DS4300 General View 11 10 9 8 5 6 4 2 1 7 3 Figure A 1 Cable with 25-pin connector Warning and Classification labels 7 2 Mounting holes 8 Warning Label 9 Laser active LED 3 Ready LED 4 Laser beam output window Good Read LED 10 Accessory mounting holes 5 External Trigger LED 11 6 Data TX LED vi
ページ8に含まれる内容の要旨
DS4300 General View 11 10 9 8 2 6 5 4 7 3 1 Figure B 1 Cable with junction box Warning and Classification labels 7 2 Mounting holes 8 Warning Label 9 Laser active LED 3 Ready LED 4 Laser beam output window Good Read LED 10 Accessory mounting holes 5 External Trigger LED 11 6 Data TX LED vii
ページ9に含まれる内容の要旨
SAFETY PRECAUTIONS LASER SAFETY The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of the DS4300 scanner. Standard Regulations This scanner utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even throu
ページ10に含まれる内容の要旨
Warning labels indicating exposure to laser light and the device classification are applied onto the body of the scanner (Figure A/B, 8 and 7 ). DATALOGIC S.p.A. Via Candini, 2 40012 LIPPO DI CALDERARA (BO) ITALY Model No. Serial No. Volt Amp. Manufactured This product conforms to the applicable requirements of 21CFR1040 at the date of manufacture. LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAXIMUM OUTPUT RADIATION 1 mW EMITTED WAVE LENGTH 630~680 nm TO IEC 825-1 (1993) Warning
ページ11に含まれる内容の要旨
POWER SUPPLY For Model DS4300-1000: This device is intended to be supplied by a UL Listed Direct Plug-In Power Unit marked "Class 2", output rated 10-30 V, minimum 0.55 A. This device may also be supplied by a UL Listed Power Unit with a "Class 2" or LPS power source which supplies power directly to the scanner via the 25-pin connector. For Model DS4300-1001: This device is intended to be supplied via the Junction Box by an NEC Class 2 Power Source, rated 10-30 V, minimum 0.55 A. x
ページ12に含まれる内容の要旨
DATALOGIC DS4300 1 GENERAL FEATURES 1.1 INTRODUCTION The DS4300 is a compact laser scanner complete with decoder which employs Datalogic’s powerful ACR™ (Advanced Code Reconstruction) technology. It was designed to satisfy the most demanding requirements associated with omni-directional scanning, reading of non-oriented barcode labels, and reading of poorly printed or damaged labels. Standard Application Program A Standard Application Program is factory-loaded onto the DS4300. This program contr
ページ13に含まれる内容の要旨
DS4300 DATALOGIC 1.2 DESCRIPTION Some of the main features of this scanner are given below: • code reconstruction • high scanning speed (800 scans/sec) • completely configurable from host computer • 2 serial communication interfaces • reads most popular codes • supply voltage from 10 to 30 Vdc • test mode to verify the reading features and exact positioning of the scanner without the need for external tools • configurable in different operating modes to suit the most various barcode reading sys
ページ14に含まれる内容の要旨
DATALOGIC DS4300 Electrical connection is provided through a cable on the side of the reader; this cable is terminated with a 25-pin connector (25-pin connector models, see paragraph 1.3, Figure A, 1 ) or by a junction box (junction box models, see paragraph 1.3, Figure B, ). 1 The laser beam output window is on the right hand side of the scanner (Figure A/B, ). A green LED on the same side indicates the laser is active 10 (Figure A/B, 9 ). A security system allows the laser to activate only onc
ページ15に含まれる内容の要旨
DS4300 DATALOGIC 1.3 AVAILABLE MODELS The DS4300 scanner is available in versions that differ in regard to the following characteristics: • Optical Resolution • Cable Termination The following models are therefore available: DS4300 - 100X Cable Termination Optical Resolution 0 = 25-pin connector 1 = Standard Resolution 1 = junction box 1.4 ACCESSORIES The following accessories are available on request for the DS4300: • 90° deflection mirror GFC-41 • Power Block 110 Vac PG110/DVE-1212A • Power Bl
ページ16に含まれる内容の要旨
DATALOGIC DS4300 2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the DS4300 reader and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: 1) DS4300 reader with cable 2) Installation manual 3) Barcode test chart 4) DS4300 communication and utility program disk 5) Mounting kit • Mounting screws and washers (4 ea.) • Mounting bracket (1) * Junction box (for junction box models only, see paragraph 1.3) 4 3 2 5 * 1 Figure 2.1 - DS4
ページ17に含まれる内容の要旨
DS4300 DATALOGIC 2.2 MECHANICAL INSTALLATION DS4300 can be installed to operate in different positions. The four screw holes (M4 x 5) on the body of the reader are for mechanical fixture (Figure 2 A/B, ). The diagram below gives the overall dimensions of the scanner and may be used for its installation. Refer to paragraph 2.5 for correct positioning. Figure 2.2 - Overall dimensions 2.2 - Installation
ページ18に含まれる内容の要旨
DATALOGIC DS4300 2.3 JUNCTION BOX INSTALLATION The junction box provides a passive connection between your scanner and the outside world in a fast and practical way. It represents an alternative to the 25-pin connector models. Figure 2.3 shows the basic layout of DS4300 using the junction box. Junction Box Scanner cable DS4300 System cables Figure 2.3 - Scanner using junction box For junction box connections, the scanner has a cable that terminates in a 24-pin connector that plugs into t
ページ19に含まれる内容の要旨
DS4300 DATALOGIC The junction box is designed to be mounted to a panel of metal, plastic or other appropriate material using the mounting screws provided in the package. To do this: 1) Open the junction box by unscrewing the 4 cover screws. If necessary, using the two mounting holes inside the junction box as a pattern, mark the panel with an appropriate object and then drill two small pilot holes in the panel. 2) Align the junction box and insert the two self-threading screws with their washers
ページ20に含まれる内容の要旨
DATALOGIC DS4300 2.3.2 Junction Box Electrical Connections The connection and wiring procedure for the junction box is described as follows: 1) Open the junction box by unscrewing the 4 cover screws. 2) Pass all System cables through the glands in the junction box housing. 3) To connect the power and input/output signals: • Prepare the individual wires of the system cables by stripping the insulation back approximately 11 mm. • Using a device such as a screwdriver, push down on the orange lever