ページ1に含まれる内容の要旨
TM
Magellan 1100i OEM
Presentation Omnidirectional Bar Code Reader
Integration Manual
ページ2に含まれる内容の要旨
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a non exc
ページ3に含まれる内容の要旨
Table of Contents Overview ........................................................................................................................... 1-1 Resources in other documents .............................................................................................. 1-1 Unpacking the Scanner ........................................................................................................ 1-2 Scanner Care .....................................................................
ページ4に含まれる内容の要旨
NOTES ® i-2 Magellan 1100i OEM
ページ5に含まれる内容の要旨
Section 1 Introduction This document gives instruction, mechanical details, and design considerations to inte grate the Magellan 1100i OEM model (designated as “scanner” or “OEM scanner” in this manual) specifically into equipment-integrated scanning applications. Overview The OEM scanner is a compact, decoded, omni-directional imaging scanner for fixed position OEM integration, such as price verifiers, kiosks, vending machines, point-of sale (POS) terminals, and other equipment-integrat
ページ6に含まれる内容の要旨
Introduction Unpacking the Scanner The scanner is shipped in custom packaging. Carefully open the package, and inspect for the following: • scanner power supply (if ordered) interface cable (if ordered) If any parts are damaged or you need additional hardware, please contact Technical Support. Scanner Care The scanner contains sensitive components which require special handling. Datalogic may not warrant damage due to improper handling. Do not open the scanner's case. Doing so will
ページ7に含まれる内容の要旨
Section 2 Mounting the Scanner This section describes how to design the mounting for optimum scanner performance. General Considerations A typical system uses the scanner mounted inside a host enclosure, with an opening for the scanning pattern to exit and read bar codes. The opening should be the size of the scanner window at a minimum, but only exposing as much of the scanner as necessary. Although the scanner has been designed to be impact-resistant, it is important to con sider the
ページ8に含まれる内容の要旨
Mounting the Scanner Cable Routing The mounting design should also take into consideration the clearances needed for the interface cable. This cable should be routed internal to the host enclosure as much as possible. It is recommended to use a flat cable or round cable without a large strain relief so that the cable can be routed away from the scanner in one of the following directions. As shown in Figure 2-1, the interface cable can be routed out the rear or bottom sur faces of the scan
ページ9に含まれる内容の要旨
94mm [3.70"] Design of the Scanner Opening Second, the scanner must be positioned so that the scan volume and illumination light will cover the entire bar code. The scan volume is shown in Figure 2-2. The combina tion of the Scan Volume and the illumination light is called the Field of View. Design ing around the scanner Field of View is explained more in the following section, Design of the Scanner Opening. Figure 2-2. Scanning Volume 147mm [5.79"] 13mm [0.5"] Scan Volume @ 165mm [6
ページ10に含まれる内容の要旨
Mounting the Scanner Integrating the Scanner Behind a Window It is not recommended to place any type of additional window between the scanner and the bar code to be read. The addition of a host enclosure window will significantly degrade scanner performance. This is due to the additional optical reflective surfaces that will cause interfer- ence with the imaging technology. CAUTION It is recommended to conduct scan performance testing with any additional window to determine if the perform
ページ11に含まれる内容の要旨
Appendix A Technical Specifications Optical and Read Performance Parameters Parameter Specification 3 3 Scan Volume 1147 cm / 70 in Scan Pattern 136 scan lines Scan Rate 1760 Digital Scan Lines/second Minimum Resolution 5 mil Depth of Field Code Size Depth of Field (100% UPC Labels) 5 mil 25.4 - 57.2mm / 1.0 - 2.25” 7.5 mil 12.7 - 69.9mm / 0.5 - 2.75” 10 mil 12.7 - 139.7mm / 0.5 - 5.5” 13 mil 12.7 - 165.1mm / 0.5 - 6.5” 20 mil 12.7 - 184.2mm / 0.5 - 7.25” Minimum Print Contrast
ページ12に含まれる内容の要旨
Technical Specifications Environmental Parameters Parameter Specification Mechanical Shock Multi 1.0m drops Contaminants Water and Dust IP52 Temperature Ranges: Operating 32 F to +122 F (0 C to +50 C) Storage -104 F to +158 F (-40 C to + 70 C) Ambient Light Indoor 0 - 6000 lux Ambient Light Outdoor 0 - 86,100 lux Humidity 5 to 95% non-condensing Beeper/Speaker 70-85dBA at a distance of 3’-3” (1 meter) Retail/Office Sine: 3.0 g pk, 5 Hz to 500 Hz Vibration 2 Random:
ページ13に含まれる内容の要旨
Appendix B Mechanical Specifications Physical Properties Parameter Specification 86.4 mm x 71.1 mm x 66.0 mm Dimensions ( 3.4” x 2.8” x 2.6”) Weight ~ 198 g / 7.0 oz. Scanner Dimensions Integration Manual B-1
ページ14に含まれる内容の要旨
Mechanical Specifications Clearance Required for Integration ® B-2 Magellan 1100i OEM
ページ15に含まれる内容の要旨
ページ16に含まれる内容の要旨
Australia Japan Datalogic Scanning Pty Ltd Datalogic Scanning KK Telephone: [61] (2) 9870 3200 Telephone: 81 (0)3 3491 6761 australia.scanning@datalogic.com japan.scanning@datalogic.com France and Benelux Latin America Datalogic Scanning SAS Datalogic Scanning, Inc Telephone: [33].01.64.86.71.00 Telephone: (305) 591-3222 france.scanning@datalogic.com latinamerica.scanning@datalogic.com Germany Singapore Datalogic Scanning GmbH Datalogic Scanning Singapore PTE LTD Telephone: 49 (0) 61 5