TABLE OF CONTENTS WARNINGS AND SAFETY INFORMATION 1 GETTING STARTED 3 YOUR BABY MONITOR 5 BASIC OPERATION 8 TROUBLESHOOTING 11 PRODUCT SPECIFICATIONS 12 GUARANTEE 13
ページ3に含まれる内容の要旨
WARNINGS AND SAFETY INFORMATION 1 Do not place the cord in a high "wear and tear" location. IMPORTANT Never use a frayed or compromised cord. Please read this user guide thoroughly before use. Never use or place your Parent or Baby units in or near Your ORICOM Baby Monitor is designed to be an aid and moisture or water (e.g. near bath or pool). Immersing in should not be used as a substitute for responsible and water can cause electric shock and even death. proper adult supervision of a chi
ページ4に含まれる内容の要旨
2 WARNINGS AND SAFETY INFORMATION • The Ni-MH batteries supplied with this product may be Battery requirements able to be recycled once they are unable to recharge during normal operation. Always observe your local Each parent unit requires two rechargeable Ni-MH Council /State regulations regarding the disposal of batteries, size AAA 1.2V 800mAh (HR10/44). your packaging materials, exhausted batteries, and old • Do not dispose of the batteries in a fi re, as they can equipment. explode.
ページ5に含まれる内容の要旨
GETTING STARTED 3 Thank you for choosing this monitor from Oricom. Installation Your Secure 100 Baby Monitor offers the best Digital clip Technology. For the Parent Unit 1 Remove the Belt Clip by lifting the clip at the top INTERFERENCE and sliding it downwards. FREE FREQUENCY 2 Then remove the battery DECT (Digital Enhanced Cordless Telecommunications) is the cover on the back of the most widely used worldwide digital cordless technology, offering Parent Unit by pressing amazingly clear
ページ6に含まれる内容の要旨
4 GETTING STARTED 5 Press [ ] to turn the Parent Unit on. 4 Press [ ] to turn on the Baby Unit. • Before fi rst use, or if it has been out of use for a long • The Baby Unit should be placed about 1 metre time, the Parent Unit will need to be charged for 15-16 to 1.5 metres away from the baby's cot on a flat hours. During this time, the Parent Unit will operate surface. Never place the Baby Unit inside the cot, from the Charger pod when switched on. Note that the bed or playpen. Make sure t
ページ7に含まれる内容の要旨
YOUR BABY MONITOR 5 Baby unit (Sender) 1 Night light Key Press to turn On the night light. Press again to turn off the Light. 2 Power On/Off Key Press to turn the Unit ON. Press and hold to turn the Unit OFF. 3 Page Key 1 2 3 Press and hold this key, Parent unit makes an audible alert. 4 Useful to call for assistance or to locate a missing Parent Unit. 4 Power light Red light glows when the power is On. A slow fl ashing light indicates batteries are low. 5 Microphone Picks up the soun
ページ8に含まれる内容の要旨
6 YOUR BABY MONITOR Left view of baby unit Parent unit (Receiver) 6 DC 6V input 7 Battery Cover Connecting to Power Adaptor. Rechargeable batteries. 8 Belt Clip 9 Volume Up/Down Keys Adjust the Volume at which you hear the sounds in your baby's room. 10 Power Key Press and release to turn it ON. Press and hold to turn it OFF. 6 10 9 8 7
ページ9に含まれる内容の要旨
YOUR BABY MONITOR 7 11 Power Light Charger Pod Red light when the power is ON. 14 Charging Light Flashing light indicates rechargeable batteries need When Parent unit is placed in the Charger Pod, the recharging. red charger light comes ON to indicate the batteries 12 Battery/Noise Level Indicators are charging. Light will remain ON to ensure optimum Indicates the battery level or Noise level charge is maintained. 13 Link Light Green light ON indicates “Linked” to Baby Unit. Flashing l
ページ10に含まれる内容の要旨
8 BASIC OPERATION Once you have set up your Baby Monitor, you will be able and 3 red). The more audio is picked up, the more to hear the sounds in your baby's room through the Parent lights will be lit. When no audio is picked up, all 8 Unit. And also see the green and red sensor lights around lights will be off. the top of the Parent Unit rise and fall with the sound levels. • If the volume of the Parent Unit is turned off, an alert Note: will sound when the audio reaches the second red If
ページ11に含まれる内容の要旨
BASIC OPERATION 9 • To stop the Page alert, press any button on the Low Battery Parent Unit, or press [ ] again on the Baby Unit. Note: Baby Unit If no button is pressed, the paging tone will stop after 2 When the battery power is low, the power light will fl ash. minutes. If the Parent Unit volume is off, the Parent Unit volume will Parent Unit reset to mid volume. When the batteries are low, the red power light will fl ash. And also the battery low warning beep will be heard. The Night l
ページ12に含まれる内容の要旨
10 BASIC OPERATION Rechargeable batteries in the Parent unit give up to 10 hours continuous usage. Please note however, that new 8 lights illuminated fully charged batteries do not reach full capacity until they have been in normal use for several days. Running rechargeable batteries right down at least once a 6 lights illuminated half charged week will help them last as long as possible. The charge capacity of rechargeable batteries will reduce with time as they age, so reducing the pe
ページ13に含まれる内容の要旨
TROUBLESHOOTING 11 Problem Possible cause(s) The red power lights do not turn on when you plug 1. Check if the units are properly connected to the power supply. in the power. 2. Check if the power is turned on. If not, Press [ ] to turn on the power. 1. You may have moved out of range. Move closer to the Baby Unit and wait 5 The green Link light on the Parent Unit is fl ashing seconds for the Link to establish. and cannot hear the sounds from your baby's 2. You may need to re −establish
ページ14に含まれる内容の要旨
12 PRODUCT SPECIFICATIONS Feature Specifi cations Operating Frequency DECT 1.8 GHz Up to 300m under optimum conditions. The range is Range reduced in buildings (up to 50m) as a result of walls, doors etc. Input: 240 V 50Hz AC Power supply (baby unit) Output: 6 V , 200 mA, DC Non rechargeable batteries (baby unit) Type: AA, 1.5 V Alkaline (not included in the package contents) Transmitting power Average: 10 mW Maximum: 250 mW Input: 240 V , 50Hz AC Power supply (parent unit) Output: 6 V , 200
ページ15に含まれる内容の要旨
GUARANTEE 13 Warranty (Australia) (a) Warranty Oricom International Pty Ltd (Oricom) warrants that Oricom will not be liable for consequential losses including loss of the product is free from defects in materials and workmanship profits arising from a cause of action in contract, tort or any other for a period of 12 months effective from the date of purchase. statutory or common law (except where a statute or any law prohibits This warranty in no way affects your statutory warranty under thi
ページ16に含まれる内容の要旨
Australia Customer Support Oricom International Pty Ltd Email: support@oricom.com.au Locked Bag 658 Web: www.oricom.com.au South Windsor, NSW 2756 Phone: 1300 889 785 Fax: (02) 4574 8898