ページ1に含まれる内容の要旨
TM TM TM TM TM
Soundweb Soundweb Soundweb 9014 9014 9014
Soundweb Soundweb 9014 9014
Installation Guide
122
TM
Soundweb
ページ2に含まれる内容の要旨
v1.0 MR/JMK 8th September 1999 Regulatory Information An example of this equipment has been tested and found to comply with the following European and international Standards for Electromagnetic Compatibility (only when used with a metal wallbox). Radiated Emissions (EU): EN55022 (1995) Associated Equip. Immunity (EU): EN50082/1 (1997) RF Immunity, Fast Transients ESD Radiated Emissions (USA): FCC part 15 Class A Important safety information - read and follow It should not be necessary to re
ページ3に含まれる内容の要旨
Use The 9014 requires 12-24v DC to be supplied externally. There are two ways of getting power into the unit: • Connect a 24v 1A DC power supply to the 2.4mm barrel connector. Up to nine more 9014s may be powered from the paralleled combicon connector. • Connect a 12-24v DC power supply to the combicon connector. A pair of 9014 Fibre Interface units are used to replace a standard category 5 Soundweb network cable. Each fibre cable will transfer 8 channels of digital audio plus control data. To u
ページ4に含まれる内容の要旨
Front panel LED functions The unit has three LED indicators showing: Power Steady - This indicates the power supply is functioning. Fibre-in Steady – Data is arriving on the fibre input. Intermittent – You have exceeded the optical power budget by either exceeding the maximum fibre length or by having too much attenuation in fibre splices. See the specification section. Cable-in Steady – Data is arriving on the cable. Rear panel connections The unit has the following connections on the rear face
ページ5に含まれる内容の要旨
Technical specifications Power Power Power Power Power DC Supply 12-24V DC, <5VA Connector Phoenix screw terminal or 2.4mm inline barrel connector Network Network Network Network Network Single RJ-45 Auto-sensed input node or output node - no setup required. Max cable length 20m Fibre Connection Fibre Connection Fibre Connection Fibre Connection Fibre Connection Snap-in SC fibre input Snap-in SC fibre output Fibre cable Fibre cable Fibre cable Fibre cable Fibre cable Multimode 62.5/125um or Mult