ページ1に含まれる内容の要旨
Video Multiplexer
Operating Instructions
Model No. WJ-FS309
WJ-FS316
WJ-FS409
WJ-FS416
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.
FS
FS
POWER
ON
OFF
POWER
ON
OFF
Video Multiplexer WJ-FS 309
Video Multiplexer WJ-FS 409
FRANÇAIS ENGLISH
ページ2に含まれる内容の要旨
Caution: Before attempting to connect or operate this product, please read the label on the bottom. For U.S.A NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part CAUTION 15 of the FCC Rules. These limits are designed to provide RISK OF ELECTRIC SHOCK reasonable protection against harmful interference when the DO NOT OPEN equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio freq
ページ3に含まれる内容の要旨
CONTENTS PREFACE .................................................................................................................................................................................... 4 FEATURES .................................................................................................................................................................................. 4 PRECAUTIONS ..................................................................................................
ページ4に含まれる内容の要旨
PREFACE The WJ-FS309 and WJ-FS316 are Black and White Video Camera and playback pictures can be displayed as Multiplexers, and the WJ-FS409 and WJ-FS416 are Color zoomed and stilled Spot pictures and Still Multiscreen pic- Video Multiplexers designed for use in surveillance security tures. systems combined with cameras, alarm sensors, a Time Setup menus for Alarm, Monitoring, Recording and Play- Lapse VCR, two video monitors and a PC. Spot pictures back are available to match system preferences
ページ5に含まれる内容の要旨
PRECAUTIONS • Refer all work related to the installation of this • Do not expose the appliance to water or moisture, product to qualified service personnel or system nor try to operate it in wet areas. installers. Do take immediate action if the appliance becomes wet. Turn the power off and refer servicing to qualified • Do not block the ventilation opening or slots on the service personnel. Moisture can damage the appliance cover. and also cause electric shock. To prevent the appliance temperat
ページ6に含まれる内容の要旨
SWITCH PROTECTOR MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS Front View t SPOT ALARM MULTISCREEN STILL EL-ZOOM POWER FS 9 CAMERA SELECT ALARM MULTI SCREEN VCR ON RESET SELECT MENU CAM SWITCH SEQ PROTECTER 1 2 3 4 5 6 7 8 9 OFF ESC Video Multiplexer WJ-FS 309 SET t CAMERA SELECT SPOT POWER ALARM MULTISCREEN STILL EL-ZOOM FS 1 2 3 4 5 6 7 8 ALARM MULTI SCREEN VCR ON RESET SELECT SEQ MENU CAM SWITCH PROTECTER 9 10 11 12 13 14 15 16 OFF ESC Video Multiplexer
ページ7に含まれる内容の要旨
The 4A screen is a compressed picture of channels !2 Electric Zoom Button (EL-ZOOM) 1 through 4, the 4B of channels 5 through 8, the 4C This button specifies the zooming area in the multi- of channels 9 through 12, and the 4D of channels screen output picture. Pressing this button displays the 13 through 16. The 9-segment screen shows the “+” sign representing the center of the area to be pictures of channels 1 through 9 in a 3x3 pattern. enlarged. While the “+” sign is displayed for 5 seconds,
ページ8に含まれる内容の要旨
Rear View i o!0 98 7 6 5 4 3 2 1 IN SIGNAL GND ALARM/REMOTE CAMERA DATA SW IN OUT 98 7 6 5 4 3 2 1 MULTI VIDEO SCREEN OUT PLAY IN REC OUT SPOT OUT u!1 io!0 16 15 14 13 12 11 10 9 8 76 5 4 3 2 1 IN SIGNAL GND CAMERA ALARM/REMOTE DATA SW IN OUT 16 15 14 13 12 11 10 9 8 76 5 4 3 21 MULTI VIDEO SCREEN OUT PLAY IN REC OUT SPOT OUT u!1 q Video Input Connectors (VIDEO IN) y Multiscreen Output Connector (MULTISCREEN OUT) These connectors accept a composite video signa
ページ9に含まれる内容の要旨
SETUP MENU In the SETUP MENU you can set preferences for ALARM, • The following buttons are used in the SETUP MENU: MONITOR, REC OUT, SEQUENCE and SYSTEM to meet your requirements. C: Moves the cursor downward. D: Moves the cursor upward. A: Moves the cursor to the left. Displaying the SETUP MENU B: Moves the cursor to the right. 1. Confirm that the camera and peripherals are connected – : Selects the mode or parameter. correctly and securely. + : Selects the mode or parameter. 2. Turn on the
ページ10に含まれる内容の要旨
Setup Menu As shown below, the SETUP MENU has five main submenus: Alarm Setup, Monitor Output Setup, Record Output Setup, Sequence Setup and System Setup. All of these submenus are further divided into additional submenus. SETUP MENU ALARM SETUP DYNAMIC REC Page 11 (Alarm Setup) (Dynamic Recording) ALM REC MODE (Alarm Recording Mode) AUTO RESET (Automatic Reset) ALM DISPLAY (Alarm Display) ALM OUTPUT (Alarm Output Duration) ALM BUZZER (Alarm Buzzer Duration) ALM INPUT (Alarm Input) VIDEO LOSS
ページ11に含まれる内容の要旨
Alarm Setup Menu GROUP SETUP WJ-FS316 SETUP CH CH CH CH ALARM SETUP ALM 1 → 1 -- -- -- MONITOR OUTPUT SETUP ALM 2 → 2 -- -- -- REC OUTPUT SETUP ALM 3 → 3 -- -- -- SEQUENCE SETUP ALM 4 → 4 -- -- -- SYSTEM SETUP ALM 5 → 5 -- -- -- ALM 6 → 6 -- -- -- ALM 7 → 7 -- -- -- ALM 8 → 8 --
ページ12に含まれる内容の要旨
Notes: 6. ALM BUZZER • If set to EXT, make sure that the CAMERA SW IN This item lets you select the ringing duration of the built-in terminal on the rear panel is connected to the Time alarm buzzer when alarm is activated. Lapse VCR. • Depending on the mutual timing between the alarm 1. Move the cursor to the ALM BUZZER parameter. trigger and the field rate, the initial picture recorded 2. Select the duration by pressing the + or – button. after an alarm is activated may not be related to the Th
ページ13に含まれる内容の要旨
9. MLT OUT MODE Monitor Output Setup Menu This item lets you select whether to switch the multiscreen 1. MULTI OUTPUT output monitor screen automatically to the camera picture of the channel whose alarm is activated. WJ-FS316 SETUP ALARM SETUP 1. Move the cursor to the MLT OUT MODE parameter. MONITOR OUTPUT SETUP REC OUTPUT SETUP 2. Select OFF or SPOT by pressing the + or – button. SEQUENCE SETUP SYSTEM SETUP The initial factory setting i
ページ14に含まれる内容の要旨
1-3. BORDER Record Output Setup Menu This item lets you select the color of the border that splits the multiscreen output pictures in a Multiscreen display. WJ-FS316 SETUP ALARM SETUP 1. Move the cursor to the BORDER parameter. MONITOR OUTPUT SETUP REC OUTPUT SETUP 2. Select the desired mode or color by pressing the + or – SEQUENCE SETUP SYSTEM SETUP button. The initial factory setting for the border color is WHITE. WHITE: White Border GRAY:
ページ15に含まれる内容の要旨
2. REC MODE Sequence Setup Menu This item lets you select the time interval (field rate) for 1. MULTI OUTPUT switching the camera channel of the REC OUT signal. When REC MODE is set to EXT, the timing is controlled by WJ-FS316 SETUP the connected VCR. When 004-255 (INT) is selected, the ALARM SETUP timing corresponds to the field rate set here. MONITOR OUTPUT SETUP REC OUTPUT SETUP The parameter settings for different VCR models are shown SEQUENCE S
ページ16に含まれる内容の要旨
1-2. SEQ MODE This item lets you select the Sequence pattern for display QUAD SEQ SETUP on the Multiscreen monitor. STEP CH SEC STEP CH SEC 1 4A 2S 9 -- 0S 2 4B 2S 10 -- 0S 1. Move the cursor to the SEQ MODE parameter. 3 9 2S 11 -- 0S 4 -- 0S 12 -- 0S 2. Select the desired Sequence mode or dwell time by 5 -- 0S 13 -- 0S pressing the + or – button.
ページ17に含まれる内容の要旨
2. SPOT OUTPUT System Setup Menu 2-1. AUTO SKIP WJ-FS316 SETUP This item lets you enable or disable the Auto Skip function to skip any steps where no video signal is present at the ALARM SETUP MONITOR OUTPUT SETUP Spot output. REC OUTPUT SETUP SEQUENCE SETUP Proceed as described in MULTI OUTPUT, 1.1 AUTO SKIP SYSTEM SETUP on page 15. 3. MLT/SPT SEQ SETUP This item lets you program or edit a Multi or a Spot Sequence. Up to 9 (16) steps can be
ページ18に含まれる内容の要旨
2. TITLE POSI TITLE SETUP MENU This item lets you select the position on the monitor where the camera title is displayed. The initial factory setting CH TITLE 1 1······· places the title at the bottom center of the monitor screen. 2 2······· 3 3······· 4 4······· 1. Move the cursor to TITLE POSI parameter, then press 5 5······· 6 6······· the SET button. The position setting menu
ページ19に含まれる内容の要旨
ON: Enables the PLAYBACK AUTO mode. 3. Move the cursor to the first (desired) digit by pressing OFF: Disables the PLAYBACK AUTO mode. the A or B button. 4. Select the desired number by pressing the + or – but- ton. 5. Repeat step 3 and 4 until all digits are registered. 5. PASSWORD 6. After registration the new password is required when This item lets you select whether to permit free or limited the operator accesses the SETUP menus. access to the Setup menus. When PASSWORD is set to ON, the ope
ページ20に含まれる内容の要旨
2. Move the cursor to the desired CAM line, and then 8. COMMUNICATION SETUP select a camera number by pressing the + or – button. This item lets you set the parameters for the Video 001 to 128: Give a camera a unique number that is not Multiplexer to communicate with the appliances linked to yet used in the RS-485 chain. the RS-485 chain. Camera numbers also need to be speci- Note: This works only for cameras connected to the fied since the system can comprise tens of units with 16 or specific V