ページ1に含まれる内容の要旨
®
Brocade Mobility RFS6000
Controller
Installation Guide
53-1001573-03 Rev B
ページ2に含まれる内容の要旨
Copyright © 2009 - 2011 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronPoint, IronShield, IronView, IronWare, JetCore, NetIron, SecureIron, ServerIron, StorageX, and TurboIron are registered trademarks, and DCFM, Extraordinary Networks, and SAN Health are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands, products, or service names are or may be trad
ページ3に含まれる内容の要旨
1 Introduction 1 Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2 Specifications 5 Physical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ページ4に含まれる内容の要旨
Verifying the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5 Regulatory Information 23 Country selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Laser devices - Gigabit Ethernet SFP option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Radio frequency interference requirements - FCC . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Radio f
ページ5に含まれる内容の要旨
About This Document In this chapter •Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v •Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v •Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v •Contacting Brocade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi •Warranty cove
ページ6に含まれる内容の要旨
Notes, cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. NOTE A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information. CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware, firmware, software, or data. DANGER A Danger statement indicates condition
ページ7に含まれる内容の要旨
Downloads http://www.brocade.com/support/ Manuals http://www.brocade.com/support/ Because quality is our first concern at Brocade, we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to: documentation@brocade.com. Provide the title and version number and as much detail as possible about your comment, including the t
ページ8に含まれる内容の要旨
Warranty coverage Contact Brocade Communications Systems using any of the methods listed above for information about the standard and extended warranties. viii Brocade Mobility RFS6000 Controller Installation Guide 53-1001573-03
ページ9に含まれる内容の要旨
Chapter Introduction 1 In this chapter •Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 •Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 •Site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 The Mobility RFS6000 Controller is a high-performance member of Brocade’s Wireless Controller family. The M
ページ10に含まれる内容の要旨
1 Warnings Warnings • Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the system to its power source. • Remove jewelry and watches before installing this equipment. • Install the equipment in a rack with adequate dimensions and weight allowances. • Verify the rack is anchored and cannot tip over or break away from its mountings. • Verify the unit is grounded before connecting it to the power source. • Verify any device
ページ11に含まれる内容の要旨
Site preparation 1 Site preparation • Consult your site survey and network analysis reports to determine specific equipment placement, port capacity, power drops, and so on. • Assign installation responsibility to the appropriate personnel. • Identify where all installed components are located. • Verify appropriate rack mounting requirements. • Provide a sufficient number of power drops for your equipment. • Ensure adequate, dust-free ventilation to all installed equipment. • Identify and prep
ページ12に含まれる内容の要旨
1 Site preparation 4 Brocade Mobility RFS6000 Controller Installation Guide 53-1001573-03
ページ13に含まれる内容の要旨
Chapter Specifications 2 In this chapter •Physical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 •Power cord specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Physical specifications 440mm (17.32 in) Width Height 44.45mm (1.75 in) Depth 390.8mm (15.38 in) 6.35 Kg (14.0 lbs) Weight Operating Temperature 0°C - 40°C Operating Humidity 5% - 85% RH, non-condensing 3 km (10000 ft) Operating Altit
ページ14に含まれる内容の要旨
2 Power cord specifications • Install an Uninterruptible Power Supply (UPS). A UPS provides continuous power during a power outage. Some UPS devices have integral surge protection. UPS equipment requires periodic maintenance to ensure reliability. A UPS of the proper capacity for the data processing equipment must be purchased. 6 Brocade Mobility RFS6000 Controller Installation Guide 53-1001573-03
ページ15に含まれる内容の要旨
Chapter LED Codes 3 In this chapter •System status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 •RJ-45 Gigabit Ethernet LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 •SFP Gigabit Ethernet LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 •Out of band management port LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 •Out of band management port status L
ページ16に含まれる内容の要旨
3 System status LEDs Start up / POST (primary system or redundant system) System status 1 LED System status 2 LED Event Off Off Power off Green Blinking Green Blinking Power On Self Test (POST) running Green Solid Green Blinking POST succeeded (Operating System Loading) Green Solid Off POST succeeded (Normal Operation) Amber Blinking Off POST Failure Alternating Green Blinking Alternating Green Blinking Boot Up Error: Device has an & Amber Blinking & Amber Blinking invalid checksum NOTE Dur
ページ17に含まれる内容の要旨
System status LEDs 3 Controller status (primary system) System status 1 LED System status 2 LED Event Off Off Power off Green Solid Off No Redundancy Feature Enabled Green Solid Green Solid Redundancy Feature Enabled Actively Adopting Access Points Green Solid Amber Blinking No License to adopt Access Points or No Country Code configured on the controller or License and Country Code configured, but no APs adopted Controller status (redundant system) System status 1 LED System status 2
ページ18に含まれる内容の要旨
3 System status LEDs Fan LED Fan LED Event Off System Off / POST Start Green Blinking POST in Process Green Solid All System Fans Normal Operation Amber Solid Redundant Cooling Failure System Operational Amber Blinking System Cooling Failure System will be held in reset until the issue is resolved Temperature status LED Temperature LED Event Off System Off Green Solid Ambient Inlet Temperature is within specified operating limit Amber Solid Ambient Inlet Temperature is near the maximum o
ページ19に含まれる内容の要旨
RJ-45 Gigabit Ethernet LEDs 3 RJ-45 Gigabit Ethernet LEDs Port Port speed status sym_006 Port Port speed status RJ-45 port speed LED Port speed LED Event Off 10 Mbps Green Solid 100 Mbps Amber Solid 1000 Mbps RJ-45 port status LED Port status LED Event Off No Link or Administratively shut down Green Solid Link present Green Blinking Activity: Transmit and Receive Brocade Mobility RFS6000 Controller Installation Guide 11 53-1001573-03
ページ20に含まれる内容の要旨
3 SFP Gigabit Ethernet LEDs SFP Gigabit Ethernet LEDs SFP port speed LED Port speed LED Event Amber Solid 1000 Mbps SFP port activity LED Port activity LED Event Off No Link or Administratively shut down Green Blinking Link present / Operational 12 Brocade Mobility RFS6000 Controller Installation Guide 53-1001573-03