Safety Precautions The following safety precautions must be taken when using your air conditioner. 1 Make sure that the indoor unit is correctly ventilated at all times; do NOT place clothing or other materials over it. 2 NEVER spill liquid of any kind into the indoor unit. Should this happen, switch off the breaker used for your air conditioner and contact your installation specialist. 3 Do NOT insert anything between the air flow blades, as the inner fan may be damaged and you may be hurt. Kee
ページ3に含まれる内容の要旨
Contents PREPARING YOUR AIR CONDITIONER Safety Precautions ........................................................................................ 2 View of the Indoor Unit.................................................................................. 4 View of the Outdoor Unit............................................................................... 4 Remote Control - Buttons and Display.......................................................... 5 Getting Started ...........
ページ4に含まれる内容の要旨
View of the Indoor Unit ❄ The design and shape are subject to change according to the model. ON/OFF switch (operation without remote control) Air Filter Air flow blades (outlet) (under the grille) Remote control sensor Air Inlet OPERATION TIMER FAN TURBO OPERATION indicator TURBO indicator - Operation : GREEN - RED - Deice : RED TIMER indicator FAN indicator - YELLOW - GREEN View of the Outdoor Unit Air Inlet Air Outlet Connection Valve E-4
ページ5に含まれる内容の要旨
M O D E T U Remote control - Buttons and Display Operating mode (AUTO, COOL, DRY, FAN, HEAT) Remote control transmission indicator Battery discharge indicator Turbo mode Temperature settings Sleep mode Fan speed Air flow direction (AUTO, LOW, MEDIUM, HIGH) Time/Timer settings Temperature adjustment buttons On/Off button Mode selection button Off Timer adjustment button (AUTO, COOL, DRY, FAN, HEAT) Turbo mode button Sleep timer button Air flow swing button Fan speed adjustment button Timer on/off
ページ6に含まれる内容の要旨
Getting Started You have just purchased a split-type room air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contain much valuable information on using your air conditioner. Please take the time to read them as they will help you take full advantage of the unit’s features. The booklet is organized as follows. The following figures are shown on pages 4 and 5: - Indoor and outdoor units - Remote control (buttons and display) They will help you fi
ページ7に含まれる内容の要旨
Installing the Remote Control Holder on the Wall The remote control is supplied with a plastic holder that can be fitted to the wall to hold the remote control when you are not using it. To attach the holder to the wall, proceed as follows. 1 With a pencil, mark the positions of the two holes on the wall where the holder is to be installed. 2 Drill the two holes and insert plugs as required for the type of wall on which the holder is being installed. 3 Screw the holder into position. Result: You
ページ8に含まれる内容の要旨
Setting the Time Your air conditioner contains a clock used to start and stop the unit automatically at a given time. You must set the time when you: Purchase the air conditioner Replace the batteries N N N No o o ot t t te e e e Be sure to reset the time when you change clocks from standard todaylight savings time and vice versa. Setting the Time for the First Time 1 Insert the batteries. Push the battery cover on the rear of the remote control with your thumb and remove it. Result: The c
ページ9に含まれる内容の要旨
M M M M M O O O O O D D D D D E E E E E T T T U U U Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed. 1 If necessary, press the (On/Off) button. Result: The OPERATION indicator on the indoor unit comes on. The air conditioner starts up in the mode selected whe
ページ10に含まれる内容の要旨
M M M M M O O O O O D D D D D E E E E E T T T U U U Cooling Your Room You must select the Cool mode if you wish to adjust the: Cooling temperature Fan speed when cooling 1 If necessary, press the (On/Off) button. Result: The OPERATION indicator on the indoor unit comes on. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. The air conditioner is fitted with a protection mechanism to IM IMPORTANT prevent the unit from being damag
ページ11に含まれる内容の要旨
M M M M M O O O O O D D D D D E E E E E T T T U U U Heating Your Room You must select the Heat mode if you wish to adjust the: Heating temperature Fan speed when heating 1 If necessary, press the (On/Off) button. Result: The OPERATION indicator on the indoor unit comes on. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. The air conditioner is fitted with a protection mechanism IM IMPORTANT to prevent the unit from being damag
ページ12に含まれる内容の要旨
M O D E T T T T T U U U U U Changing the Room Temperature Quickly The Turbo cooling/heating function is used to cool or heat your room as quickly as possible. Example: You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected. 1 If necessary, press the (On/Off) button. Result: The OPERATION i
ページ13に含まれる内容の要旨
M M M M M O O O O O D D D D D E E E E E T T T U U U Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. 1 If necessary, press the (On/Off) button. Result: The OPERATION indicator on the indoor unit comes on. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. The air conditioner is fitted with a protection mechanism IM IMPORTANT
ページ14に含まれる内容の要旨
M M M M O O O O D D D D E E E E T T U U Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. 1 If necessary, press the (On/Off) button. Result: The OPERATION indicator on the indoor unit comes on. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. 2 If the indication is not displayed at the top of the remote control, press the button on the remote control one or more times
ページ15に含まれる内容の要旨
Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. 1 Press the button under the remote control flap one or more times as required. Result: The outer blade is adjusted vertically. RECOMMENDATION When... Adjust the blade to face... Cooling Upwards. Heating Downwards. 2 If you want the blade to
ページ16に含まれる内容の要旨
M M O O D D E E T U Switching the Unit On and Off Automatically (On/Off Timer) You can set the timer to switch the air conditioner on and/or off automatically at given times. Example: You wish to start cooling your room before you return from work; you decide to: Switch the air conditioner on at 5:30 p.m. Switch it off at 11:30 p.m. You can set: The switch-on time only The switch-off time only Both the switch-on and switch-off times Check that the current time is correct before setting
ページ17に含まれる内容の要旨
M O D E T U Setting the Sleep Timer The Sleep Timer can be used when you are cooling or heating your room to switch the air conditioner off automatically after a period of six hours. N N N No o o ot t t te e e e If you wish to switch the unit off at a specific time, refer to page 16. 1 Make sure that you have selected either the or the mode. 2 Press the button . Result: The indoor unit beeps. The indication is displayed. The air conditioner will be controlled a
ページ18に含まれる内容の要旨
M O D E T U Setting the Quick Timer The Quick Timer enables you to set the air conditioner to switch off automatically after a given period of time, by pressing one single button. The unit can be switched off automatically after 30 minutes, one hour, two hours, three hours or five hours. N No ot te e If you wish to switch the unit off at a specific time, N No ot te e refer to page 16. 1 If necessary, switch the air conditioner on and select the required mode. 2 Press one or more times unt
ページ19に含まれる内容の要旨
M O D E T U Cancelling the On/Off Timer If you no longer wish to use the On/Off Timer that you have set, you can cancel it at any time. 1 To cancel the... Then press... Switch-on timer . Result:The indication flashes. Switch-off timer . Result:The indication flashes. 2 Press the button. Result: The indoor unit beeps. The TIMER indicator on the indoor unit switches off if no other timer is currently set. The air conditioner operates normally. Cancelling the Sleep Timer If y
ページ20に含まれる内容の要旨
Operating Recommendations Here are a few recommendations that you should follow when using your air conditioner. Topic Recommendation Heating performances The heat pump inside the air conditioner absorbs heat from outside air and brings it indoors. If the temperature of the outside air drops, the air conditioner will heat less. If you find that the room is not warm enough, use an additional heating appliance. Warm air circulation The air conditioner circulates warm air to heat your room; as a re