MIC612 Thermal Camera Table of Contents | en 3 Table of Contents 1Safety 6 1.1 About this Manual 6 1.2 Conventions in this Manual 6 1.3 Legal Information 6 1.4 Important Safety Instructions 6 1.5 EC Directives 8 1.6 Important Notices 8 1.7 FCC and ICES Compliance 10 1.8 Bosch Notices 11 1.9 Customer Support and Service 11 2 Unpacking 12 2.1 Parts List 12 2.2 Additional Products Required 12 2.3 Additional Tools Required 12 3 Installation Overview 13 3.1 Typical Mounting Arrangements 14 3.2 Mounti
ページ4に含まれる内容の要旨
4 en | Table of Contents MIC612 Thermal Camera 5.4 Setting the Addresses of the Two Cameras of the MIC612 33 5.4.1 Setting the Address of the Optical Camera via FastAddress 34 5.4.2 FastAddress, Bosch Protocol 34 5.4.3 FastAddress, Pelco Protocols 35 5.4.4 Active Commands in FastAddress 36 5.5 Setting Passwords 36 5.5.1 Special Passwords 36 5.5.2 Setting Passwords, Bosch Protocol 36 5.6 Configuring the Camera for Inverted Operation 36 6 On-Screen Display (OSD) Menus (Bosch Protocol) 37 6.1 Camer
ページ5に含まれる内容の要旨
MIC612 Thermal Camera Table of Contents | en 5 10.4 Pre-position Tour 64 10.5 Azimuth, Elevation, and Compass Directions 64 10.5.1 Setting the Azimuth Zero Point 64 10.5.2 Displaying Azimuth, Elevation, and Compass Headings 65 11 Maintenance and Troubleshooting 66 A Keyboard Commands By Number 67 A.1 Keyboard Commands (Bosch Protocol) 67 A.1.1 Commands, Optical Camera 67 A.1.2 Commands, Thermal Camera 69 A.2 Keyboard Commands (Pelco Protocol) 71 Index 73 Bosch Security Systems, Inc. Installation
ページ6に含まれる内容の要旨
6 en | Safety MIC612 Thermal Camera 1Safety 1.1 About this Manual This manual has been compiled with great care and the information it contains has been thoroughly verified. The text was complete and correct at the time of printing. Because of the ongoing development of products, the content of the manual may change without notice. Bosch Security Systems accepts no liability for damage resulting directly or indirectly from faults, incompleteness, or discrepancies between the manual and the
ページ7に含まれる内容の要旨
MIC612 Thermal Camera Safety | en 7 CAUTION! TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT THE POWER SUPPLY BEFORE OPENING THE POWER SUPPLY UNIT. POWER DISCONNECT: POWER SUPPLY UNITS HAVE POWER SUPPLIED WHENEVER THE POWER CORD IS INSERTED INTO THE POWER SOURCE. WARNING! INSTALLATION SHOULD BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, ANSI/NFPA, CANADIAN ELECTRIC CODE, AND ALL LOCAL COUNTRY CODES. BOSCH SECURITY SYSTEMS ACCEPTS NO LIABILITY FOR ANY
ページ8に含まれる内容の要旨
8 en | Safety MIC612 Thermal Camera 8. Do not point the camera at the sun. Bosch Security Systems will not be liable for any damage to cameras that have been pointed directly at the sun. 9. Do not back drive the pan or tilt axis of the camera. Doing so will damage the motor drive gear chain and will invalidate the warranty. NOTICE! This device is intended for use in public areas only. U.S. federal law strictly prohibits surreptitious recording of oral communications. 1.5 EC Directives The MIC
ページ9に含まれる内容の要旨
MIC612 Thermal Camera Safety | en 9 – For 18 VAC units, voltage applied to the unit's power input should not exceed ±10%. User-supplied wiring must comply with local electrical codes (Class 2 power levels). Do not ground the supply at the terminals or at the unit's power supply terminals. – If unsure of the type of power supply to use, contact your dealer or local power company. Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held li
ページ10に含まれる内容の要旨
10 en | Safety MIC612 Thermal Camera 1.7 FCC and ICES Compliance FCC ET ICES INFORMATION (commercial applications) (U.S.A. and Canadian Models Only, CLASS A) NOTICE! This is a class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: – this device may not cause harmful interference, and – this device
ページ11に含まれる内容の要旨
MIC612 Thermal Camera Safety | en 11 Au besoin, l’utilisateur consultera son revendeur ou un technicien qualifié en radio/télévision, qui procédera à une opération corrective. La brochure suivante, publiée par la Commission fédérale des communications (FCC), peut s’avérer utile : « How to Identify and Resolve Radio- TV Interference Problems » (Comment identifier et résoudre les problèmes d’interférences de radio et de télévision). Cette brochure est disponible auprès du U.S. Government Printi
ページ12に含まれる内容の要旨
12 en | Unpacking MIC612 Thermal Camera 2 Unpacking CAUTION! Take extra care lifting or moving MIC612 cameras because of their weight (10.66 kg / 23.5 lb). – This equipment, although ruggedized, should be unpacked and handled with care. Check the exterior of the packaging for visible damage. If an item appears to have been damaged in shipment, notify the shipper immediately. – Verify that all the parts listed in the Parts List below are included. If any items are missing, notify your Bosch
ページ13に含まれる内容の要旨
MIC612 Thermal Camera Installation Overview | en 13 3 Installation Overview CAUTION! Installation should be made by qualified service personnel and conform to the National Electrical Code and applicable local codes. The MIC Series cameras are designed for easy installation on a variety of common fittings. The most common type of mount used is a dedicated CCTV camera pole where the camera is bolted directly to the top using industry-standard 4 in. (101.6 mm) fitting. This type of camera pole
ページ14に含まれる内容の要旨
14 en | Installation Overview MIC612 Thermal Camera 3.1 Typical Mounting Arrangements Below are examples of typical mounting arrangements for MIC Series cameras. Figure 3.2 Typical pole mount (showing Pole Mount Bracket (MIC-PMB) with Shallow Conduit Adapter (MIC- SCA) and Wall Mount Bracket (MIC-WMB)) Number Description 1 Securing bolts for Shallow Conduit Adapter 2 90 mm stainless steel pole banding 3 Blocks for Pole Mount Bracket 4 Plate for Pole Mount Bracket 5 Securing bolts for plate for P
ページ15に含まれる内容の要旨
MIC612 Thermal Camera Installation Overview | en 15 Figure 3.4 Typical corner mount (from left to right: Wall Mount Bracket (MIC-WMB), Shallow Conduit Adapter (MIC-SCA), and Corner Mount Bracket (MIC-CMB)) 3.2 Mounting Positions CAUTION! The upright unit can be mounted either with the camera ball up or down. To get the picture the correct way for installation with the camera ball down, rotate the camera tilt axis 180°. For more information, see Section 5.6 Configuring the Camera for Inverted
ページ16に含まれる内容の要旨
16 en | Installation Overview MIC612 Thermal Camera 3.3 About the MIC Shielded Composite Cable MIC shielded composite cables are multi-conductor cables of various lengths (and gauges ranging from 14 - 18) that provide all power, video, and telemetry connections between the MIC PSU and the MIC camera. The cables are pre-made with a female-terminated 14-pin connector at one end for attachment to the male connector installed into the base of the camera. The other end of the cables has free (non
ページ17に含まれる内容の要旨
MIC612 Thermal Camera Installation | en 17 4 Installation CAUTION! Installation must be made by qualified personnel and conform to ANSI/NFPA 70 (the National ® Electrical Code (NEC)), Canadian Electrical Code, Part I (also called CE Code or CSA C22.1), and all applicable local codes. Bosch Security Systems, Inc. accepts no liability for any damages or losses caused by incorrect or improper installation. CAUTION! Ensure that a strong tether between the camera pan shaft and the mounting surf
ページ18に含まれる内容の要旨
18 en | Installation MIC612 Thermal Camera Example 2: Configuration with RS-485 protocol connection Figure 4.2 MIC612 connected to a MIC power supply, which is connected to a head-end control system by RS-485. Number Description 1 Biphase connection between MIC power supply and head-end control system 2 Video connection between MIC power supply and head-end control system 3 Shielded composite cable between MIC camera and MIC power supply 4 Head-end control system (with Divar 400 or 600 or simil
ページ19に含まれる内容の要旨
MIC612 Thermal Camera Installation | en 19 4.3 Mounting the Camera CAUTION! Fasteners are not supplied with MIC612 cameras because the type of fastener used depends on the material to which the fastener is attached. The material must accommodate a minimum pull-out strength of 275 kg (600 lbs.) Fasteners can include wedge anchors, sleeve anchors, single expansion anchors, double expansion anchors, machine screw anchors, or "Thru- Bolting" with a nut. All fasteners must be made of 303(A2) stai
ページ20に含まれる内容の要旨
20 en | Installation MIC612 Thermal Camera example, one of the securing bolts) to the camera’s outside case, and should be attached to the Earth terminal post on the PCD base of the camera. – If the system is copper throughout and the camera pictures are fed back to the control room via coaxial copper cable, then the camera should be earthed only at the video termination point in the control room. In this case, the "Earth Link" on the PCB should be broken. Refer to Section 4.4.1 Earth Link o