ページ1に含まれる内容の要旨
DX4010i
Installation Instructions
RS-232 Serial Interface
EN Module
ページ2に含まれる内容の要旨
DX4010i | Installation Instructions | Trademarks Trademarks • BlackBox® is either a registered trademark or a trademark of BlackBox Corporation in the United States and/or other countries. 2 Bosch Security Systems, Inc. | 1/05 | 4998141106C
ページ3に含まれる内容の要旨
DX4010i | Installation Instructions | Contents Contents 1.0 General Information .......................................4 2.0 Specifications ....................................................4 3.0 Installation Standards .....................................4 4.0 Wiring .................................................................5 5.0 DX4010i Jumper Pin Settings ........................6 5.1 Enable LED Jumper Pins (P2)...........................6 5.2 DB9 Ground Enable Pins (P1) ..
ページ4に含まれる内容の要旨
DX4010i | Installation Instructions | 1.0 General Information 1.0 General Information Figure 1: DX4010i Component Layout The DX4010i is a data terminal equipment (DTE) 5 6 configured RS-232 serial device interface (SDI) module designed to operate with compatible control panels. It LED E NABLE Rx Tx TxRx BUS SER connects to the control panel through the option or P2 4 P6 SDI data bus. 7 The DX4010i is used to connect a PC with RPS, BIS, 3 PC 9000, CMS 7000, or other third party softwa
ページ5に含まれる内容の要旨
DX4010i | Installation Instructions | 4.0 Wiring 4.0 Wiring Figure 3: External Power Supply Connections Remove all power to the control panel (AC 1 2 and standby battery) before making or breaking any connections. Failure to do so 3 can result in personal injury or damage to the equipment. 4 Wire Length Restrictions 5 • 0.8 mm (#22 AWG): 305 m (1000 ft) 6 • 1.2 mm (#18 AWG): 610 m (2000 ft) SDI wiring is limited to 305 m (1000 ft). +- 7 Connect the DX4010i to the control pan
ページ6に含まれる内容の要旨
DX4010i | Installation Instructions | 5.0 DX4010i Jumper Pin Settings Figure 5: Parallel Device Connections Figure 6: P2 Jumper Settings LED ENABLE 1 Rx Tx Tx Rx BUS SER P2 P6 LED ENA BLE RxTx TxRx BUS SE R P2 P6 P1 DB9 GND ENABLE P3 P1 2 DB 9 GND ENAB LE P3 2 1 4 3 1- Parallel converter cable box (BlackBox P/N: PI045A 1- Diagnostic LED enable pins (P2) 2- Parallel printer (compatible option bus control 2- DB9 GND enable pins (P1) panels only) 3- Enabled 4- Disabled 5.0 D
ページ7に含まれる内容の要旨
DX4010i | Installation Instructions | 6.0 Remote Programming Direct Connection 5.3 Address DIP Switches 6.0 Remote Programming The address DIP switches are used to assign an address to the DX4010i. Direct Connection Refer to Table 3 for DIP switch option bus address The DX4010i can be used to create a local direct settings. connection for remote programming of a compatible Refer to Table 4 for DIP switch SDI bus address control panel. settings. Option Bus: Set the address DIP swi
ページ8に含まれる内容の要旨
DX4010i | Installation Instructions | 6.0 Remote Programming Direct Connection Table 3: Option Bus Address DIP Switch Settings DIP Switch Settings DIP S1 S2 S3 S4 S5 S6 S7 S8 Switches Module 1 2 4 8 16 32 64 128 Address (Mode) (Option/SDI) (Checksum +1) 0* ON ON ON ON ON OFF ON OFF OFF ON ON ON ON OFF ON OFF 1 2 ON OFF ON ON ON OFF ON OFF 3 OFF OFF ON ON ON OFF ON OFF 4 ON ON OFF ON ON OFF ON OFF 5 OFF ON OFF ON ON OFF ON OFF 6 ON OFF OFF ON ON OFF ON OFF 7 OFF OFF OFF ON ON
ページ9に含まれる内容の要旨
DX4010i | Installation Instructions | 6.0 Remote Programming Direct Connection Table 4: SDI Bus Address DIP Switch Settings SDI DIP Switch Settings SDI DIP S1 S2 S3 S4 S5 S6 S7 S8 Switches Module 1 2 4 8 16 32 64 128 Address (Mode) (Option/SDI) (Checksum +1) 80* ON ON ON ON OFF OFF OFF OFF 81 OFF ON ON ON OFF OFF OFF OFF ON OFF ON ON OFF OFF OFF OFF 82 83 OFF OFF ON ON OFF OFF OFF OFF ON ON OFF ON OFF OFF OFF OFF 84 85 OFF ON OFF ON OFF OFF OFF OFF 86 ON OFF OFF ON OFF OFF O
ページ10に含まれる内容の要旨
DX4010i | Installation Instructions | 7.0 DB9 DTE RS-232 Connector (P6) 7.0 DB9 DTE RS-232 Figure 8: DB9 Connector Layout Connector (P6) 1 2 3 4 5 The DX4010i serial port is wired as a DTE device. • If the connected device is a data carrier equipment (DCE) device (most common, such as an external modem), a straight through 9-pin to 9-pin, or (DTE to DCE) 9-pin to 25-pin cable may be used. 6 7 8 9 • If the connected device is a DTE device (such as 1- DCD 6- DSR a PC serial port)
ページ11に含まれる内容の要旨
DX4010i | Installation Instructions | 8.0 RJ-16 Data Bus Connector (P3) 8.0 RJ-16 Data Bus Connector (P3) Figure 9: P3 Connector LED ENABLE Rx Tx Tx Rx BUS SER P2 P6 P1 DB9 GND 1 ENABLE P3 1- RJ-16 data bus connector (P3) For remote programming connection, use one of the two cables supplied: RJ-16 to molex for control panels with the data bus provided on a header (such as the D6412 or DS7240) or the RJ-16 to spade lugs for terminal strip connections (such as the D9412).
ページ12に含まれる内容の要旨
Bosch Security Systems 130 Perinton Parkway Fairport, NY 14450-9199 Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 Bosch Security Systems 130 Perinton Parkway Faiport, NY 14450-9199 USA Customer Service: (800) 538-5807; Technical Support: (888) 886-6189 © 2005 Bosch Security Systems 4998141106C