ページ1に含まれる内容の要旨
SSA-P102
SSA-P102T
Access Control Panel
user manual
imagine the possibilities
Thank you for purchasing this Samsung product.
To receive more complete service,
please visit our website.
www.samsungsecurity.com
ページ2に含まれる内容の要旨
safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit. This exclamation point symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accom
ページ3に含まれる内容の要旨
SAFETY INFORMATION 5. Keep out of direct sunlight and heat radiation sources. It may cause fi re. 6. Install it in a place with good ventilation. 7. Avoid aiming the controller directly towards extremely bright objects such as sun. 8. Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall be placed on the apparatus. 9. The Mains plug is used as a disconnect device and shall stay readily operable at any time. FCC Statement This device comp
ページ4に含まれる内容の要旨
contents 5 FeatureS PRODUCT INTRODUCTION 6 What’s included 9 Cable Selection 5 10 Connecting the termination resistor and INSTALLATION AND EXTERNAL diode CONNECTION 11 Earth-grounding the communication cables 12 Power, Reader, and I/O Connection 15 Communication Line Connection 10 19 System Initialization INITIALIZATION 19 Reader Input Bit Setup 20 Board ID Setting 20 Communication Speed Setup 19 21 Troubleshooting TROUBLESHOOTING 21 23 Product Specifi cations PRODUCT SPECIFICATIONS 23 4_ conte
ページ5に含まれる内容の要旨
PRODUCT INTRODUCTION product introduction FEATURES This is a state-of-the-art single door access controller device that provides a high level security system in an affordable price, meeting the needs in the security industry. With its user-friendly interface, this product enables user manipulation easy and simple for whatever you want to perform in a high level of stability. With its user-friendly interface, it can register cards between 10,000 and 50,000, within which you can change, delete,
ページ6に含まれる内容の要旨
product introduction Time Scheduling You can specify a time range during which a specifi c operation is performed. You can specify a specifi c time range for a schedule code, which will be transferred to the applicable device. You can specify up to 5 different time ranges for a day, ranging from Monday to Sunday including holidays. Each time schedule code can be applied with a single different (or same) holiday code. Door Open Alarm and Forced Door Open Alarm The Door Open Alarm function notifi
ページ7に含まれる内容の要旨
PRODUCT INTRODUCTION Main Board 2 3 4 5 6 1 14 13 30 7 20 8 21 9 22 10 23 11 12 24 17 15 25 18 26 16 19 27 28 29 Used to attach SSA-P102 to the closure using a metal supporter. (Ensure that you use 1 Fixing Hole the metal supporter to prevent the EMI.) 2 2Pin DIP Switch Used to set the type of a connected reader to either 26bit Wiegand or 34bit Wiegand. The device address and communication speed specifi ed by the applicable switch should be consistent with those of the computer that is used for
ページ8に含まれる内容の要旨
product introduction Input #3 Input Port: The fl ashing LED indicator denotes that a signal is sensed by the port. 10 Input Port: The fl ashing LED indicator denotes that a signal is sensed by the port. Input #2 11 (connected to the Door Contact Sensor.) All other sensors are not allowed. Input Port: The fl ashing LED indicator denotes that a signal is sensed by the port. 12 Input #1 (connected to the Exit button.) All other input sources are not allowed. MCU Module 13 MCU module connection port
ページ9に含まれる内容の要旨
PRODUCT INTRODUCTION CABLE SELECTION RS-232 RS-422/RS-232 Converter HOST PC RS-422 RS-422 RS-422 DC12V DC12V Power Supply Power Supply RF Reader Lock/Alarm RF Reader Lock/Alarm Exit Button/Sensor Input Exit Button/Sensor Input Item Cable Type DC 12V Product Power This Belden #9409, 18 AWG 2 Conductor, Unshielded 1 product Belden #9512, 22 AWG 4 Conductor, Shielded Reader (Power and Data) External 2 Reader This product Belden #9514, 22 AWG 8 Conductor, Shielded Door Contact
ページ10に含まれる内容の要旨
installation and external connection CONNECTING THE TERMINATION RESISTOR AND DIODE Termination Resistor A resistor is inserted for matching the line’s impedance to prevent distortion and reduction in RS-422 or RS-485 long distance data communications, which is referred to as termination resistor. Note that termination resistors of lower than 90 are not allowed, neither more than one termination resistor is accepted for the communications system. A RS-485 RS-485 RS-485/RS-232 Converter B 120
ページ11に含まれる内容の要旨
INSTALLATION AND EXTERNAL CONNECTION EARTH-GROUNDING THE COMMUNICATION CABLES We recommend you to use a proper grounding system for the communication cables. The best grounding method is to earth-ground the shield wire of the communication cable. However, the earth-grounding of the communication cable is not easy at all, and it also causes an increased installation cost. There are three grounding points available for installation: 1. Earth Ground 2. Chassis Ground 3. Power Ground The mo
ページ12に含まれる内容の要旨
installation and external connection POWER, READER, AND I/O CONNECTION Power Connection Check the location of the power port. DC +12V GND - Connect the plus (+) line of DC 12V to the corresponding port (+12V). - Connect the plus (-) line of DC 12V to the GND (-) port. Reader Connection BLACK GND READER #2 WHITE D1 GREEN D0 RED +12V BLACK GND READER #1 WHITE D1 GREEN D0 RED +12V - You can safely use other power sources for the reade
ページ13に含まれる内容の要旨
INSTALLATION AND EXTERNAL CONNECTION PUSH PUSH Input Connection GND INPUT #5 GND INPUT #4 GND INPUT #3 GND Door Contact INPUT #2 GND Exit Button INPUT #1 - The Input #1 and Input #2 ports have the Exit button and the Door Contact Sensor installed, while Input #3 to Input #5 can be confi gured to your preference. - Exit Button Connection Connect one line of the Exit button to IN 1. Connect the other line of the Exit button to GND. - Door Contact Sensor Connection Connect one line of the Door Con
ページ14に含まれる内容の要旨
installation and external connection Output Connection + Normal COM Open NO - +12V GND NC + Normal Close COM - Cathode Anode +12V GND 1N4004 ~ 1N4007 or equiv. - According to the operation mode, the Door Lock type is classifi ed in two: NC (Normal close) and NO (Normal Open). Make the connection as appropriate. - To prevent a risk of voltage surge during the lock operation, it is recommended to use the bypass diode. - If the Door Lock type is POWER FAIL SAFE 1. Connect the COM (common) line
ページ15に含まれる内容の要旨
INSTALLATION AND EXTERNAL CONNECTION COMMUNICATION LINE CONNECTION RS-232 Communication Port Connection A 9-pin connector for serial communication is required to make connection to the PC. Connect the 9 pin connector for RS-232 communications as follows: HOST PC RS-232 2 3 5 9-Pin Female Connector 1. Connect RS-232-TX to pin #2 of the 9-pin connector. 2. Connect RS-232-TX to pin #3 of the 9-pin connector. 3. Connect RS-232-GND to pin #5 of the 9-pin connector. 4. Connect the serial communication
ページ16に含まれる内容の要旨
installation and external connection RS-422 Communication Port Connection (Standalone) The RS-422/RS-232 converter is required to establish RS-422 communications. Connect the 9-pin connector of the RS-422/RS-232 converter as follows: RS-422/RS-232 Converter RxD RS-232C TxD Power HOST T+ T- R+ R- MAX. 1200m TX- TX+ RX- RX+ 1. Connect RS-422-TX(-) to the RX(-) port of the converter. 2. Connect RS-422-TX(+) to the RX(+) port of the converter. 3. Connect RS-422-RX(-) to the TX(-) port of the conve
ページ17に含まれる内容の要旨
INSTALLATION AND EXTERNAL CONNECTION RS-422 Communication Port Connection (Multiple Units) The RS-422/RS-232 converter is required to establish RS-422 communications with SSA-P102. RS-422/232 Converter RxD RS-232C TxD Power T+ T- R+ R- HOST MAX. 1200m TX- TX+ RX- RX+ SSA-P102 - Follow the guidelines below to make connection between devices. 1. Connect TX(-) of one device to TX(-) of other one. 2. Connect TX(+) of one device to TX(+) of other one. 3. Connect RX(-) of one device to RX(-) of other
ページ18に含まれる内容の要旨
installation and external connection TCP/IP Communication Port Connection 1) TCP/IP Communication Connection HUB TCP / IP TCP / IP PC SSA-P102T is required to establish TCP/IP communications. J 2) Cabling Connect the LAN cable to the TCP/IP RJ-45 jack as shown. 1. Connect the RJ45 jack of the unit to the RJ45 plug, the LAN cable of the network system. 2. Set a unique communication address (COMM ADDR) for each unit 3. Install and launch the application (SAMS). 18_ installation and external conn
ページ19に含まれる内容の要旨
INITIALIZATION Initialization SYSTEM INITIALIZATION Initializing the system using the Initialize switch Apply the power and initialize the system by using the initialization switch. 1. Locate the Initialize switch ( ) on the upper right corner Initialize Switch and press both switches simultaneously. • Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep. Releasing both switches will stop the beep, and restarts the system after the initiali
ページ20に含まれる内容の要旨
initialization BOARD ID SETTING Device Address and Each device in the multi-serial communication connection is assigned with a Communication Speed unique number to identify each other. 1. The initial value of the switch is “0”, and all of the 8 switches are defaulted to OFF. 2. Each switch has a unique value, and the board ID is the sum of the values of the switches. • You can specify a value between 0 and 31 for the board ID. Communication Speed Address ❖ Refer to the example b