ページ1に含まれる内容の要旨
INSTALLATION/OPERATION
Data Adapters
®
DX2000DA9, DX2000DA9T, & DX2000DA25T
C697M-A (7/02)
ページ2に含まれる内容の要旨
IMPORTANT SAFEGUARDS AND WARNINGS Observe the following WARNINGS before installing and using this product. 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. The product and/or manual may bea
ページ3に含まれる内容の要旨
DESCRIPTION The DX2000 Data Adapters are used to connect any serial device, such as a cash register, retail point-of-sale (POS) terminal, or bank automated teller machine (ATM), to the DX2000 Digital Video Recorder (DVR) or DX2000 Data Hub. Each DX2000 DVR can directly control one device per data port (the DX2000 DVR has four ports). In order to control multiple devices through a single data port, you must use a data hub. Up to seven devices can be connected to each data hub and each device requ
ページ4に含まれる内容の要旨
POS CONFIGURATIONS DX2000DA9 POS CONFIGURATION RJ-45 OR RJ-11 CABLE TO DX2000 DVR OR DX2000 DATA HUB 20158 Figure 2. DX2000DA9 POS Configuration Use the DX2000DA9 Data Adapter to connect a POS device’s DB9 serial output port to the DVR or data hub. You can use RJ-45 or RJ-11 cable. DX2000DA9T POS CONFIGURATION RJ-45 OR RJ-11CABLE TO DX2000 DVR OR DX2000 DATA HUB EXISTING DATA CABLE Figure 3. DX2000DA9T POS Configuration Use the DX2000DA9T Data Adapter and “Y” cable to connect a POS device’s DB
ページ5に含まれる内容の要旨
ATM CONFIGURATIONS DX2000DA9 ATM CONFIGURATION RJ-45 OR RJ-11 CABLE TO DX2000 DVR OR DX2000 DATA HUB 20161 Figure 5. DX2000DA9 ATM Configuration Use the DX2000DA9 Data Adapter to connect an ATM’s DB-9 serial output port to the DVR or data hub. You can use an RJ-45 or RJ-11 cable. DX2000DA25T ATM CONFIGURATION RJ-45 OR RJ-11 CABLE TO DVR OR DATA HUB SNA NETWORK CABLE 20162 Figure 6. DX2000DA25T ATM Configuration Use the DX2000DA25T Data Adapter to connect the existing DB25 SNA (Systems Network
ページ6に含まれる内容の要旨
SWITCH SETTINGS DX2000DA9/DX2000DA9T ADAPTER SWITCH SETTINGS SW2 SW1 20164 Figure 8. DX2000DA9 Adapter Switch Settings Switch SW1 lets you choose between data transmission (TX) or reception (RX) for the POS/ATM device’s output. Set the switch to the TX position (factory default) when connecting directly to the device’s DB9 output port. If connecting to the device’s existing output data cable, you may have to change the switch to the RX position if you are not using a straight data cable. The th
ページ7に含まれる内容の要旨
WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to workmanship for a period of one year after the date of shipment. Exceptions to this warranty are obtain a Repair Authorization number (RA), and provide the following information: as noted below: 1. Model and serial number • Five years on Pelco manufactured camer
ページ8に含まれる内容の要旨
® World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO9001 Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada