ページ4に含まれる内容の要旨
SETUP FIGURE 4 PARAMETERS FOR SAT PROGRAMMING In order to program and operate the SAT from the 9760-KBD, some preparatory groundwork must be laid by programming the following 9760 configuration files: the Comms, Camera and Link Camera files. Use Figures 4, 5 and 6, respectively, as guides. These are essentially the only files that need to be programmed on the 9760 SIDE for basic SAT operation. FIGURE 5 FIGURE 6 SAT MENU ACCESS FROM THE 9760-KBD Programming SAT menus using a KBD200, 300 or 300V
ページ5に含まれる内容の要旨
ALARM IMPLEMENTATION ISSUES (if needed, reference the attached Default SAT Menu Settings Sheet) Alarm programming involves configuring SAT Monitor and Alarm For each destination to be programmed, Pelco recommends that menus and, possibly, some 9760 System configuration files. If you you not stray outside the guidelines outlined below for program- program alarm functions without regard to the status of the ming the various menus until you are quite familiar with the monitor-out lines on the SAT,
ページ6に含まれる内容の要旨
SYSTEM ONLY (Continued) ➟ System-only implementation of alarms also requires that configuration files be programmed on the 9760 SIDE of the configuration. In the Systems Configuration file, specify an Alarm Control Mode of operation. FIGURE 7 More importantly, in the Comms Configuration file: Assign alarm monitors for the 9760 operator ➟ to view alarms on. FIGURE 8 Of equal importance is the CC1 Alarms file: Fill in the alarm information fields opposite ➟ the physical alarm # th
ページ7に含まれる内容の要旨
COMBINED LOCAL AND SYSTEM Here, you need to pay close attention to the specific monitor-out line you are setting menu attributes for. For all monitor-outs connected to a LOCAL monitor, assign Monitor menu attributes just as they were listed and discussed under LOCAL ONLY. For all monitor-outs configured as a TIE LINE, assign Monitor menu attributes just as they were listed and discussed under SYSTEM ONLY. The difference between LOCAL ONLY and SYSTEM ONLY as opposed to COMBINED or shared alarm im
ページ8に含まれる内容の要旨
SAT DEFAULT MENU SETTINGS C1510M-QS – CM9760-SAT Quick Start Reference Guide –7–
ページ9に含まれる内容の要旨
® Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA In North America and Canada Tel (800) 289-9100 • FAX (800) 289-9150 International Customers Tel +1(559) 292-1981 • FAX +1(559) 348-1120 www.pelco.com C1510M-QS – CM9760-SAT Quick Start Reference Guide –8–
ページ1に含まれる内容の要旨
ADDENDUM
Addendum No.: C1577M-A
Date: August 4, 2004
Manuals Affected: CM9760 Series Manuals – C538M, C539M-A, C540M-B, C541M-C, C542M-B, C543M-A,
C544M, C549M-A, C572M, C573M-D, C578M, C579M, C1501M, C1503M, C1510M-QS,
C1510M-A, C1520M-B, C1528M-C, C1940M, C1941M, C1942M, and C1943M
Manual Update: The CM9760-CC1 has been replaced with the CM9700-CC1 and the CM9760-MGR manage-
ment software has been replaced with the CM9700-MGR management software.
Keep the following in mind when referring to th
ページ2に含まれる内容の要旨
CM9760-SAT QUICK START REFERENCE GUIDE FOR: the 9760-SAT physical interface setup parameters for SAT programming from the 9760-KBD ® alarm implementation issues CONNECT THE CC1 TO THE SAT (RS-422) Figure 1 shows a CM9760-SAT connected to a 9760 system. Of particular interest are the COMM and tie line connections. The COMM connection shown in Figure 1 is the line between port 7 on the CC1 and the COM 2 connection on the SAT. This is detailed in Figure 2. FIGURE 1 C1510M-QS – CM9760-SAT Quic
ページ3に含まれる内容の要旨
FIGURE 2 THE CC1 TO THE SAT (TIE LINES) Tie lines (a minimum of one, a maximum of four) are connected in sequential, ascending order to monitor- outs on the SAT. Don’t skip around. Use Figure 3 as a guide. FIGURE 3 C1510M-QS – CM9760-SAT Quick Start Reference Guide –2–