Operating Instructions for Master-Bilt Alarm/Light Module (19-14009)
19-14009
Walk-In Temp / Door /Alarm / Light Module
1. GENERAL WARNINGS
1.1 PLEASE READ BEFORE USING THIS MANUAL
• This manual is part of the product and should be kept close to the instrument for easy and quick
reference.
• The instrument shall not be used for purposes different from those described hereunder. It cannot be
used as a safety device.
• Check the application limits before proceeding.
1
ページ2に含まれる内容の要旨
1598003200 Operating Instructions for Master-Bilt Alarm/Light Module (19-14009) 3.1 FRONT PANEL OPERATION In Programming Mode press to select a parameter or to confirm an operation. * Press and hold this key for more than 5 s to turn the controller OFF. Press and hold this key for more than 1 s to turn the controller back ON. Press to see the HIGH Temp ALARM (ALU parameter) HIGH Press to see the LOW Temp ALARM (ALL parameter) LOW In Programming Mode press to browse
ページ3に含まれる内容の要旨
1598003200 Operating Instructions for Master-Bilt Alarm/Light Module (19-14009) 5. PROGRAMMING 5.1 HOW TO CHANGE A PARAMETER VALUE MAIN MENU 1. Enter the Programming Mode by pressing the SET and DOWN key for 3s ( and start blinking). 2. Select the required parameter. 3. Press the “SET” key to display its value (now only the LED is blinking). 4. Use “UP” or “DOWN” to change its value. Press “SET” to store the new value and move to the following parameter. To exit: Press SET + UP o
ページ4に含まれる内容の要旨
1598003200 Operating Instructions for Master-Bilt Alarm/Light Module (19-14009) 6.2 LIGHT BUTTON REGULATION: I1L = N The light button has a higher priority than digital inputs therefore: - if the light was switched on by button the digital input can not modify its status. - if the light was switched on by digital input, the light button can modify its status. 7. INSTALLATION AND MOUNTING 7.1 MOUNTING OF XWA11V – PR10000 The XWA11V must be mounted on vertical panel. The Te
ページ5に含まれる内容の要旨
1598003200 Operating Instructions for Master-Bilt Alarm/Light Module (19-14009) 10.1 SILENCING BUZZER Once the alarm signal is detected the buzzer can be silenced by pressing the UP key. 10.2 ALARM RECOVERY Probe alarms : “P1” (probe1 faulty), “P2” ; they automatically stop 10s after the probe restarts normal operation. Check connections before replacing the probe. T° alarms “HA” and “LA” automatically stop as soon as the thermostat T° returns to normal values or when the defros
ページ6に含まれる内容の要旨
1598003200 Operating Instructions for Master-Bilt Alarm/Light Module (19-14009) 13. PARAMETER MAP LABEL DESCRIPTION VALUE LEVEL RANGE Thermostat probe [-12,0°C <> 12,0°C] [- 0 Pr2 ot calibration 21°F <> 21°F] CF T° measurement unit F Pr2 °C(0) - °F(1) rES Resolution (only °C) in Pr2 dE(0) - in(1) UT Display update 60 Pr2 0 <> 255 (s) OnF Off function enabling y Pr2 n(0) - Y(1) °C[ ALL <> 150,0°] °F[ 50 Pr1 ALU High Tempalarm setting ALL <> 302°] °C[ -50.0° <> ALU]
ページ7に含まれる内容の要旨
1598003200 Operating Instructions for Master-Bilt Alarm/Light Module (19-14009) 14. PARAMETER LIST Ot Thermostat probe calibration: (-12.0÷12.0°C/ -21÷21°F) allows to adjust possible offset of the thermostat probe. CF T measurement unit: °C = Celsius; °F = Fahrenheit. When the measurement unit is changed the Set Point and the values of some parameters have to be modified. rES Resolution (for °C): (in = 1°C; dE = 0.1 °C) allows decimal point display. Ut Display update: The time d