ページ1に含まれる内容の要旨
Airlines & Avionics Products
Honeywell Inc.
15001 N.E. 36th Street
Redmond, WA 98052
MK VI
MK VIII
Enhanced Ground Proximity Warning System
(Class A TAWS)
Installation Design Guide
Hardware/Software Part Numbers:
965-1180-020
965-1190-020
965-1210-020
965-1220-020
Release Date: July 14, 2003
Proprietary notice on title page applies
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV: SHEET 1 OF 326
ページ2に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide Copyright 2003 Honeywell, Inc. All rights reserved. This document and all information and expression contained herein are the property of Honeywell International Inc., and is provided to the recipient in confidence on a need to know basis. Your use of this document is strictly limited to a legitimate business purpose requiring the information contained therein. Your use of this document constitutes acceptance of these terms. Propri
ページ3に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide Typed names constitute approval signatures. Actual signatures are on file at Honeywell in Redmond, WA. DRAWN Larry Matter 14-JULY-03 CHECK ENGR Larry Matter 14-JULY-03 MFG QA APVD Jim Mulkins 14-JULY-03 APVD REVISION STATUS OF SHEETS INDEX ADDED SHEETS ADDED SHEETS SHEET REV SHEET REV SHEET REV SHEET REV SHEET REV SHEET REV NUMBER LTR NUMBER LTR NUMBER LTR NUMBER LTR NUMBER LTR NUMBER LTR REVISIONS SH REV DESCRIPTION DATE APPROVED Propri
ページ4に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide THIS PAGE INTENTIONALLY LEFT BLANK Proprietary notice on title page applies CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV: SHEET 4
ページ5に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide TABLE OF CONTENTS SECTION I GENERAL INFORMATION ..........................................................................................................13 1.1 INTRODUCTION.........................................................................................................................................................13 1.2 APPLICABILITY...............................................................................................
ページ6に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide 2.1 INTRODUCTION.......................................................................................................................................................29 2.2 UNPACKING AND INSPECTING THE EQUIPMENT......................................................................................................29 2.3 EQUIPMENT INSTALLATION ...................................................................................................
ページ7に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide 3.4.6 Instructions .........................................................................................................................................................62 3.5 CATEGORY 3 POSITION INPUT SELECT ................................................................................................................63 3.5.1 ARINC 743 Format............................................................................................
ページ8に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide 3.11.7 Digital ARINC 429 Dual IOC buses (Cat. 9 ID 250 - 255) ...........................................................................96 3.11.8 Instructions .......................................................................................................................................................97 3.12 CATEGORY 10 ATTITUDE INPUT SELECT.......................................................................................
ページ9に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide 3.15.2.11 Terrain Display Select #1 & #2 Discrete....................................................................................................................... 111 3.15.2.12 Terrain Pop up Discrete ................................................................................................................................................ 112 3.15.3 Instructions ...................................................................
ページ10に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide APPENDIX A - CUSTOMER WORKSHEET .....................................................................................................137 APPENDIX B - SAMPLE WIRING DIAGRAMS ...............................................................................................141 APPENDIX C WINVIEWS OPERATION INSTRUCTIONS.........................................................................146 APPENDIX D - VENDOR CONTACT INFORMATION...........
ページ11に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide SECTION I GENERAL INFORMATION Proprietary notice on title page applies CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV: SHEET 11
ページ12に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide SECTION I GENERAL INFORMATION SECTION I GENERAL INFORMATION ..................................................................................................................... 13 1.1 INTRODUCTION.............................................................................................................................................................. 13 1.2 APPLICABILITY...............................................................
ページ13に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide SECTION I GENERAL INFORMATION 1.1 Introduction The Honeywell MK VI/MK VIII Enhanced Ground Proximity Warning System (MK VI/MK VIII EGPWS) provides alerts and warnings to prevent controlled flight into terrain (CFIT). This Installation Design Guide must be used in conjunction with the Interface Description Document (Appendix E) for the MK VI/MK VIII Enhanced Ground Proximity Warning System (MK VI/MK VIII EGPWS) to select features and desi
ページ14に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide 1.4 Reference Documents Following is a list of Honeywell reference documents: 965-1180-601 Product Specification for the MK VI and MK VIII Enhanced Ground Proximity Warning System (EGPWS) 965-1180-201 Outline, MK VI EGPWC (without GPS) 965-1190-201 Outline, MK VI EGPWC (with GPS) 965-1210-201 Outline, MK VIII EGPWC (without GPS) 965-1220-201 Outline, MK VIII EGPWC (with GPS) 060-4199-180 Line Maintenance Manual 060-4267-000 MK VIII EGPWS T
ページ15に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide 1.5 Description of Equipment The MK VI/MK VIII EGPWS is a rack mount ground proximity warning (GPWS) and terrain awareness and warning (Class A TAWS) computer. Some of the system features include: ♦ Basic Ground Proximity Warning Modes 1-5 ♦ Mode 6 Altitude Callouts and Bank Angle alert ♦ Terrain Clearance Floor ♦ Terrain and Obstacle Awareness alert and display ♦ Terrain map with runways >= 2000 feet in length (optionally >= 3500 feet in
ページ16に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide approximately 35 days. GPS initialization time should be less than 3 minutes with active RTC data. If the capacitor has discharged then GPS initialization time may be as long as 10 minutes. 1.5.4 GPS Antenna and Cabling EGPWS installations using the internal GPS require a GPS antenna and cabling. The GPS antenna should meet the following qualifications: Frequency: 1575.42 MHz Impedance: 50 ohms Gain: 33 dB max, 26.5 dB preferred Power: 5
ページ17に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide 1.5.5 OAT Sensor The EGPWS uses a separate OAT sensor (Outside Air Temperature) to measure outside air temperature on aircraft that do not have another compatible source of outside air temperature. Outside Air Temperature is used by the EGPWS along with pressure altitude in the Geometric Altitude computation. If Outside Air Temperature is not available, Geometric Altitude is computed using pressure altitude and GPS Altitude with a correspo
ページ18に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide 1.6 Technical Characteristics MK VI / VIII EGPWS TSO Compliance: (MK VI) TSO-C92c, TSO-C151b Class A (MK VIII) TSO-C92c, TSO-C151b Class A, TSO-C117a Application for UKCAA Spec 14 is in process Physical size (HxWxD): 6.20 x 3.04 x 10.30 Weight: 3.9 pounds maximum Mounting: Standard 3 inch King Radio rack Temperature (operational): -55°C to +70°C (F2) Altitude range: 55,000 feet (F2) Cooling: No cooling necessary Shock: No shock mounting
ページ19に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide The MK VI EGPWS is normally shipped with an AMERICAS Terrain database. When ordering a MK VI EGPWS that will be 1 operating in the ATLANTIC or PACIFIC region the specific Terrain database must be specified with the order. NOTE 1: Terrain Database cards for the ATLANTIC or PACIFIC region are no longer required to be ordered separately. NOTE 2: -XXX defines Application software version. 1.7.2 MK VIII EGPWS The MK VIII EGPWS is available in t
ページ20に含まれる内容の要旨
Honeywell MK VI MK VIII EGPWS Installation Design Guide Bendix/King 071-04003-0002 Computer Mounting Tray 1 EA 405-0383-001 1.8.2 RS-232 Cable The MK VI/MK VIII EGPWS RS-232 Cable can be ordered using the following part numbers: NOTE: The RS-232 Cable can be built by the Installer/Operator per the description in Section 4.4.2. Vendor Name Vendor P/N Description QTY UM Honeywell P/N Honeywell 704-2617-001 RS-232 Cable 1 EA 704-2617-001 1.8.3 Smart Cable The MK VI/MK VIII EGPWS Smart Cable can be