Intelliguard 9000
SECURITY SYSTEM
SPECIFICATION DATA
I9000 CONTROL UNIT I9000 CONTROL UNIT
AND POWER SUPPLY AND POWER SUPPLY
RS-232
PRO 9000
(RS-485 WITH RRI)
(SOFTWARE
EBI
NOT INCLUDED)
NOTE: PRO 9000 MAY
ONLY BE CONNECTED
TO ONE I9000 CU AT A TIME.
AREA
MULTIPLE
KEYPAD
CONTROL
OUTPUT MODULE
CENTER 2 KEYPAD RS-485 TO
RS-485
I9000 DEVICES
HALL EFFECT BIC-2 BIC-6
DOOR SWITCH INPUT MODULE INPUT/OUTPUT MODULE M14456A
SYSTEM FEATURES
Adaptable for a wide range of applications. 8003-242 2-
ページ2に含まれる内容の要旨
INTELLIGUARD 9000 SECURITY SYSTEM All events are sorted by day and date and then recorded in an Intelligent Switching Power Supply (ISP) event log. ISP FEATURES The I9000 recognizes a maximum of 99 users, plus one Red LED Communication Indicator is disabled if no reserved for service personnel, and five security levels with jumper is present on the ISP tamper input. individual identification numbers (ID) and passwords. Green LED AC On Indicator. Switch selectable address (0, 1, 2, or
ページ3に含まれる内容の要旨
INTELLIGUARD 9000 SECURITY SYSTEM Wiring Connections: Table 1 describes the connections Each I9000 CU supports a maximum of seven RIPS. The between the I9000 CU and its input and output devices. Use a control unit supports up to eight ISPs (four per RS-485 port), RS-232 cable to connect the CU to the EBI. Use twisted pair seven in the RIPS (one per RIPS) and one located in the cable to connect the RS-485 CU ports to the I9000 input and I9000 control unit enclosure. Depending on the installat
ページ4に含まれる内容の要旨
INTELLIGUARD 9000 SECURITY SYSTEM Features Control Center 2 Keypads Serial numbered deviceno address switch setting Each I9000 CU supports a requiredlearned through the KID Keypad in maximum of four Control conjunction with a CC2 Keypad or using PRO9000. Center 2 (CC2) Keypads, two per communication channel Quick Reference guide (protruding from the top of the maximum. Each CC2 displays KID) can be extended as required. current system status and Keypad insert can be used to ide
ページ5に含まれる内容の要旨
INTELLIGUARD 9000 SECURITY SYSTEM For installation or service, three onboard switchesin BIC-2 Input Concentrator conjunction with the LED displayallow the technician to The BIC-2 supports a maximum of two configure the unit. In this mode, the BIC-6 annunciates the input (detection) and one output, programmed loop type for each loop which can then be configured by the installer. The inputs modified using the switches. can be any standard detection device such as a sensor or contact swi
ページ6に含まれる内容の要旨
INTELLIGUARD 9000 SECURITY SYSTEM Communication: RS-485 receiving and transmitting signals. Minimum Operating Current: 13.9 mA at 14.5 Vdc (outputs set to Type 0 or 3, outputs not active, parameter 0 = 0, tamper Enclosures: = normal, all switched loads powered separately). BIC-2 Input Module: Plastic polycarbonate. White with white Maximum Operating Current: 98.7 mA at 14.5 Vdc (all output actuators. drivers powered on (outputs set to Type 0, outputs active) BIC-2 HU Input Module: Plastic p
ページ7に含まれる内容の要旨
INTELLIGUARD 9000 SECURITY SYSTEM RRI. Whether the EBI workstation is connected to a single 8003-280 Sensor I9000 or multi-dropped to several I9000 control units, the distance between units will be extended up to 3,277 ft (999m). FEATURES The distance is based on the assumption that the units are Serial numbered device, no address switch setting extreme opposite devices with the longest cable length required. between them, not the devices that are physically located the Learned throu
ページ8に含まれる内容の要旨
INTELLIGUARD 9000 SECURITY SYSTEM PRO9000 Software Configure the I9000 and define detection points using the IMPORTANT PRO9000 Software (not included with the I9000 CU). Product damage or failure may occur if this system is PRO9000 Software is a DOS application. It runs on any PC not installed and operated according to this specifi- compatible computer running MS-DOS, Version 5.0 or higher, cation. or Microsoft® Windows 95 in a DOS window, or Windows 2000 in a DOS full screen window. Refer to