ページ1に含まれる内容の要旨
ADEMCO VISTA-10P
ADEMCO VISTA-10PSIA
Security Systems
Installation and Setup Guide
K0735V3 10/04 Rev. B
ページ2に含まれる内容の要旨
RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Proper Coverage for the Protected Premises. Recommendations For Smoke And Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below. Early warning fire detection is best achieved by the installation of fire
ページ3に含まれる内容の要旨
Table Of Contents ••••••••••••••••••••••••••••••••••• Features and Installation Highlights...............................................................................................1-1 Capabilities.............................................................................................................................................1-1 Functions.......................................................................................................................................
ページ4に含まれる内容の要旨
Table Of Contents ••••••••••••••••••••••••••••••••••• Menu Mode Programming...................................................................................................................5-1 Zone Programming Overview (∗56 and ∗58 Menu Modes)................................................................5-1 ∗56 Zone Programming Procedure......................................................................................................5-1 ∗58 Expert Programming Mode Procedures ........
ページ5に含まれる内容の要旨
SECT ION 1 Features and Installation Highlights •••••••••••••••••••••••••••••••••••• SIA Installations: The VISTA-10PSIA is a certified SIA-compliant control that meets SIA specifications for False Alarm Reduction. The VISTA-10P is not certified as SIA compliant, but can be programmed for False Alarm Reduction. To program for False Alarm Reduction, follow the SIA Guidelines noted in the applicable programming fields. Capabilities • Up to 22 zones plus eight keyfob zones (zones 49-56)
ページ6に含まれる内容の要旨
Installation and Setup Guide NOTE: All devices and accessories used in a Canadian installation must be Listed for use in Canada. Important Installation Highlights (Installer Please Read) • This system uses addressable keypads and Relay Modules (see table of addresses in Programming Overview section). • Keypads must be set for addresses 16-23 (first keypad is address 16, which is different from previous controls) and programmed in data fields *190-*196. • 4204 Relay Modules m
ページ7に含まれる内容の要旨
SECT ION 2 Mounting and Wiring the Control •••••••••••••••••••••••••••••••••••• Cabinet and Lock 1. Mount the control cabinet to a sturdy wall in a clean, dry area, which is not readily accessible to the general public, using fasteners or anchors (not supplied) with the four cabinet mounting holes. 2. Remove cabinet door, then remove the lock knockout from the door. Insert the key into the lock. 3. Position the lock in the hole, making certain that the latch will make contact with th
ページ8に含まれる内容の要旨
Installation Instructions Mounting Board with RF Receiver 1. a. Remove the receiver board from its case, then insert the top of the board into the slots at the top of the cabinet, as shown in Detail A in Figure 3. Make sure that the board rests on the correct row of tabs. b. Swing the base of the board into the mounting clips and secure it to the cabinet with the accompanying screws. c. Insert the top of the control's board into the slot in the clips and position two clips at the lowe
ページ9に含まれる内容の要旨
Mounting and Wiring the Control Wiring to Keypads 1. Connect keypads to the keypad terminals as shown on the Summary of Connections diagram. Determine wire size using the Wire Run Chart below. 2. Set keypad addresses. Refer to the address setting instructions included with the keypads and set each keypad device address according to the chart at right. 3. Program the keypad addresses and sound options in data fields *190-*196. IMPORTANT: Each keypad must be assigned a unique address, s
ページ10に含まれる内容の要旨
Installation Instructions Sounder (Bell) Connections TERMINALS ON EXTERNAL ALARM 1. Make sounder connections to alarm output CONTROL BOARD SOUNDER terminals 3 (+) and 4 (–). For supervised output, continue with steps 2 _ 4 and 3. _ 2000 ALARM 2. Cut the red Bell Supervision Jumper located OBSERVE OHM OUTPUT POLARITY EOL TERMINALS + above terminals 2 and 3 on the control board. RESISTOR + 3 3. Connect a 2k ohm resistor across the terminals of the last sounder. 2 IF BELL SUPERVISION IS E
ページ11に含まれる内容の要旨
Mounting and Wiring the Control CALIFORNIA STATE FIRE MARSHALL (CSFM) AND UL RESIDENTIAL FIRE 24-HOUR BATTERY BACKUP REQUIREMENTS The California State Fire Marshal and UL have regulations which require that all residential fire alarm control panels must be provided with a backup battery which has sufficient capacity to operate the panel and its attached peripheral devices for 24 hours in the intended standby condition, followed by at least 4 minutes in the intended fire alarm signalin
ページ12に含まれる内容の要旨
Installation Instructions Hardwire Zones Normally Open Zones/ Normally Open EOLR Zones 1. Connect open circuit devices in parallel across the loop; for EOLR zones, connect the EOLR across the loop wires at the last device. 2. Enable normally open/EOLR zones using Zone Programming mode, “Hardwire Type” prompt. Normally Closed Zones/Normally Closed EOLR Zones 1. Connect closed circuit devices in series in the high (+) side of the loop; for EOLR zones, connect the EOLR in series following
ページ13に含まれる内容の要旨
Mounting and Wiring the Control Installing the RF Receiver You can any ADEMCO 5800 Series Wireless Receivers, including: RF Receiver No. of Zones 5881L/5882L up to 8 5881M/5882M up to 16 (transmitter zone numbers = 9-24; button zone numbers = 49-56) 5883, 6150RF up to 16 (transmitter zone numbers = 9-24; button zone numbers = 49-56) 1. Set Device Address to “00” as described in its instructions (set all switches to the right, “off” position). 2. Mount the receiver, noting that the
ページ14に含まれる内容の要旨
Installation Instructions Installing the Transmitters 1. To be sure reception of the transmitter's signal at the proposed mounting location is adequate, perform a Go/No Go Test, described in the Testing the System section. 2. Install transmitters in accordance with the instructions provided with each. 3. Set 5827, 5827BD, 5804BD wireless keypads to the programmed House ID (field *24), using its DIP switches (5827) or follow the instructions provided with the device. ULC NOTE: In accorda
ページ15に含まれる内容の要旨
Mounting and Wiring the Control 5-PIN TRIGGER CONNECTOR 1345 U L A UL Listed keyswitch is required for fire installations and UL commercial and residential burglar alarm installations. If a keyswitch is used on: • an installation that transmits opening and closing 4-WIRE 4146 KEYSWITCH CABLE signals, the keyswitch zone must be programmed to (ARMED) RED send opening and closing signals. YELLOW • a UL commercial burglar alarm installation, the (READY) GREEN keyswitch’s tamper switc
ページ16に含まれる内容の要旨
Installation Instructions On-Board Triggers 5-PIN TRIGGER CONNECTOR Connect field wiring to the desired trigger pin on 1345 the 8-pin trigger connector centrally located above the terminal strip. You can use a 4-wire cable as shown. U L If on-board triggers are used, the wiring between the control unit and the UL Listed device must be run in conduit, be no more than 3 feet apart and have no intervening barriers or walls. 4-WIRE CABLE 00-trigcon-005-V3 Figure 12. On-Boa
ページ17に含まれる内容の要旨
{ { Mounting and Wiring the Control U L The 4285 and 4286 modules are UL Listed only for use on residential fire and UL residential burglar alarm installations. Phone Module Problems If no touch tones are produced following access to the security system from on-premises (this problem may arise in rare cases), it may be necessary to reverse the wires connected to terminals 3 and 4 on the phone module and the wires connected to terminals (21) & (22) on the control. The wiring diagra
ページ18に含まれる内容の要旨
Installation Instructions Audio Alarm Verification Connections (AAV, “listen-In”) Refer to the connection diagrams below. One diagram shows connections when a 4285/4286 Phone Module is used, the other shows connections when the 4285/4286 is not used. Connections use one of the on-board triggers. U UL installations using the AAV feature must use the ADEMCO UVCM module (part of the ADEMCO UVS L system) Suggested AAV Module: ADEMCO UVS (shown) or Eagle 1250 NOTES • Set field *91
ページ19に含まれる内容の要旨
SECT ION 3 Programming Overview •••••••••••••••••••••••••••••••••••• About Programming You can program the system at any time, even at the installer's premises prior to the actual installation. Programming can also be performed remotely from the installer’s office/home, using an IBM personal computer, a modem, and Compass downloading software. The following is a list of the various Programming modes used to program this system: Programming Mode… Used to … Data Field Programm
ページ20に含まれる内容の要旨
Installation Instructions Wireless Receiver, Transmitters, and Wireless Keys (keyfobs) Receiver: Set the receiver’s address to “00” using its DIP switches, then set the following options: † *22 RF Jam Option *24 RF House ID Code (if using wireless keypads) † *67 Transmitter Low Battery Report Code † These fields must be enabled for Residential † Fire, UL Residential Burglar Alarm, and UL *75 Transmitter Low battery restore report code Commercial Burglar Alarm installations. *1