ADEMCO VISTA SERIES
VISTA-20P / VISTA-20PSIA
VISTA-15P / VISTA-15PSIA
Security Systems
Installation and Setup Guide
K5305-1V5 10/04 Rev. A
ページ2に含まれる内容の要旨
RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Proper Coverage for the Protected Premises. Recommendations For Smoke And Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below. Early warning fire detection is best achieved by the installation of fire
ページ3に含まれる内容の要旨
Table Of Contents Features and Installation Highlights............................................................................................................1-1 Capabilities and Functions................................................................................................................................................1-1 Compatible Devices ......................................................................................................................................
ページ4に含まれる内容の要旨
Table Of Contents (continued) Data Field Programming .................................................................................................................................4-1 About Data Field Programming........................................................................................................................................4-1 ∗ System Setup Fields ( 20 – ∗29) ...........................................................................................................
ページ5に含まれる内容の要旨
SECT ION 1 Features and Installation Highlights This manual applies to the following Honeywell security systems: ADEMCO VISTA-20P/ADEMCO VISTA-20PSIA/ADEMCO VISTA-20PCN (collectively referred to as VISTA-20P series), ADEMCO VISTA-15P/ADEMCO VISTA-15PSIA/ADEMCO VISTA-15PCN (collectively referred to as VISTA-15P series) Features and procedures apply to all, except where differences are noted. SIA Installations: The VISTA-20PSIA and VISTA-15PSIA are certified SIA-compliant controls th
ページ6に含まれる内容の要旨
Installation and Setup Guide Compatible Devices Device VISTA-20P VISTA-15P Notes Addressable Keypads 8 8 6150 Fixed-Word Keypad, 6160 Alpha Keypad, 6150V Fixed-Word Display Voice Keypad, 6160V Alpha Display Voice Keypad, 6150RF Keypad/Transceiver Touch Screen (AUI) 2 2 Touch Screen (AUI) devices are in addition to the 8 Devices addressable keypads. E.g., Symphony, 6270 4219, 4229 Zone Up to 5 for Up to 2 for Zone numbers are predefined according to the device Expander Modules up to 40 u
ページ7に含まれる内容の要旨
SECT ION 2 Mounting and Wiring the Control Installing the Control Cabinet and PC Board PUSH Cabinet and Lock 1. Mount the control cabinet to a ON LOCK UNTIL IT CHECK sturdy wall in a clean, dry area, SNAP IS SEATED POSITION TAB SECURELY which is not readily accessible to LOCKED the general public, using fasteners PUSH or anchors (not supplied) with the four cabinet mounting holes. SNAP 2. Remove cabinet door, then remove TAB UNLOCKED the lock knockout from the door. Insert th
ページ8に含まれる内容の要旨
Installation and Setup Guide CABINET AB CABINET BOARD RECEIVER CIRCUIT BOARD SUPPORTING SLOTS + + CIRCUIT BOARD MOUNTING CLIP CONTROL CIRCUIT BOARD DETAIL A SIDE VIEW MOUNTING OF BOARD - CLIP SUPPORTING SLOTS INSTALLATION WITH RECEIVER CIRCUIT BOARD ANTENNA (2) SCREW (2) GROUNDING LUG (2) WHITE BLACK RED MOUNTING MOUNTING MOUNTING CLIP CLIP CLIP NOTE A COMBINATION OF THESE MOUNTING CLIPS HAS BEEN ANTENNA MOUNT INCLUDED IN YOUR INSTALLATION KIT. (2 PLACES) USE THE APPROPRIATE CLIPS FOR MOUNTING
ページ9に含まれる内容の要旨
Signal X10 Sync AC AC Output Common Data Mounting and Wiring the Control AC Power, Battery, and Ground Connections 1321 Transformer Connect the 1321 Transformer (1321CN in Wire Run Chart Canada) to terminals 1 and 2 on the Distance from control Wire Size control board. See Wire Run Chart for Up to 50 feet # 20 wire size to use. 50–100 feet # 18 • Use caution when wiring the 100-250 feet # 16 transformer to the control to guard against blowing the transformer fuse 1 2 (the fuse
ページ10に含まれる内容の要旨
ARMED READY Installation and Setup Guide Sounder (Bell) Connections Basic Connections Make sounder connections to alarm output terminals 3 (+) and 4 (–). • The 12VDC sounder output activates when an alarm occurs. 3 4 • Total current drawn from this output cannot exceed 2 amps (going beyond 2 amps will overload the power supply, or may cause the electronic circuit protecting the sounder output to trip). • You must install a battery, since the battery supplies this current. Supervised
ページ11に含まれる内容の要旨
BYPASS IN ARMED 1 OFF 2 AWAY 3 STAY READY 4 MAX 5 TEST 6 7 STANT 8 CODE 9 CHIME READY 0 # Mounting and Wiring the Control Keypad Notes Set device addresses. Refer to the instructions included with the devices and set each address according to the Table of Devices Addresses. See Keypad Programming Fields (fields *190-*196) in Section 4. Data Field Programming for details on enabling keypad addresses, assigning keypad partitions and selecting keypad sounding options. IMPORTANT: Each
ページ12に含まれる内容の要旨
Installation and Setup Guide Hardwire Zones and Zone Expansion Hardwire Zones Normally Open Zones/ N.O. EOLR Zones 1. Connect open circuit devices in parallel across the loop; for EOLR zones, connect the EOLR across the loop wires at the last device. 2. Enable normally open/EOLR zones using Zone Programming mode, “Hardwire Type” prompt. Normally Closed Zones/ N.C. EOLR Zones 1. Connect closed circuit devices in series in the high (+) side of the loop; for EOLR zones, connect the EO
ページ13に含まれる内容の要旨
Mounting and Wiring the Control Smoke Detector Notes • • Fire Verification (zone type 16): The control panel will “verify” a fire alarm by • • resetting the smoke detectors after the first alarm trigger, and then waiting 90 seconds for a second alarm trigger. If the smoke detector or thermostat does not trigger again, the control will disregard the first trigger, and no alarm signal will occur. This feature eliminates false alarms due to electrical or physical transients. SIA Inst
ページ14に含まれる内容の要旨
Installation and Setup Guide RELAY 4229 RELAY CONNECTOR DIP SWITCH 2 FOR SETTING ADDRESS EITHER OR BOTH CAN BE USED AND ZONE "A" RESPONSE TERMINALS ON CONTROL PANEL RELAY 1 TB2 4-PIN CONSOLE PLUG GRN NO C NC DATA OUT (>) 4 (TERM 6) TO CONTROL TAMPER JUMPER POSITION 4229 IN CABINET BLK (–) GROUND 3 (TERM 4) (NOT TAMPER) 4 4229 REMOTE 3 RED 2 (+) 12VDC (TERM 5) (TAMPER PROTECTED) 2 TB1 DATA IN (<) YEL 1 FROM (TERM 7) 1 1 2 3 4 5 6 7 8 9 12 10 11 CONTROL TERMINATE EACH RLY RLY PROGRAMMED ZON
ページ15に含まれる内容の要旨
Mounting and Wiring the Control Installing a 5800TM • Use this module only if you are using one or more wireless bi-directional keypads or Module keyfobs with a wireless Receiver; 5800TM is not necessary if using a Transceiver (e.g., 5883). • The 5800TM must be set to address 28 (cut red-W1 jumper). • The 5800TM can be used in partition 1 only. • For additional information regarding the 5800TM, refer to the 5800TM’s instructions. 1. Mount the 5800TM next to the RF receiver (betwee
ページ16に含まれる内容の要旨
Installation and Setup Guide Installing a Keyswitch Keyswitch Connections 1. Connect the 4146 keyswitch's normally open momentary switch to a zone’s (2-8) terminals. Remove the 2000 ohm EOL resistor if connected across the selected zone. 2. Using a standard keypad cable as shown: Connect the yellow and white keyswitch wires to trigger connector pin 3 (+12V). Connect the Red and Green LED wires to the appropriate output 17/output 18 trigger connector pins. 3. Connect a 2000 ohm EOL
ページ17に含まれる内容の要旨
Mounting and Wiring the Control Connecting Relay Modules, Powerline Carrier Devices and Output Triggers 4204/4229 Relay Modules 1. Mount either remotely or in the control panel. 2. Connect each module to the control’s keypad terminals and set the device addresses as previously described in the Connecting Keypads and Other Addressable Device section. Use the connector harness supplied with the module. Use standard 4-conductor twisted cable for long wiring runs. VISTA-20P: Up to 16 rel
ページ18に含まれる内容の要旨
Installation and Setup Guide On-Board Triggers Connect field wiring to the desired trigger pin on the 8-pin trigger connector centrally located above the terminal strip. • If using 1361X10 transformer and powerline carrier devices, use the SA4120XM-1 cable (part of 4120TR Trigger Cable). See Wiring the AC Transformer section for transformer connections. • If only using the on-board triggers, you can use a 4-wire cable (N4632-4, supplied with the control) as shown below. 8-PIN
ページ19に含まれる内容の要旨
{ { Mounting and Wiring the Control Phone Line/Phone Module, and Audio Alarm Verification (AAV) Connections Phone Line Connect incoming phone line and handset wiring to the main terminal block (via an RJ31X jack) as shown in the Summary of Connections diagram at the back of this manual. Wire colors represent the colors of the cable to the RJ31X jack. 4285/4286 Phone Module 1. Make 12V (+) and (–) and data in and data out connections from the phone module to the control, using the
ページ20に含まれる内容の要旨
Installation and Setup Guide Audio Alarm Verification • Refer to the connection diagrams below. One diagram shows connections when a Connections 4285/4286 Phone Module is used, the other shows connections when the 4285/4286 is not (AAV, “listen-In”) used. • Connections use one of the on-board triggers. • Set field *91 for AAV and program the appropriate output (output 17 or 18) using *80 Menu mode: select zone type 60 and output action 1 (close for 2 seconds) or action 2 (stay