ページ1に含まれる内容の要旨
Speed Dome
EPTZ3000/EPTZ3000I
USER MANUAL
Date: Nov 2008
ページ2に含まれる内容の要旨
Table of Contents 1. EPTZ3000/EPTZ3000I OVERVIEW.................................................... 1-3 1.1. Introduction .............................................................................................1-3 1.2. Specifications ..........................................................................................1-5 1.3. Feature .....................................................................................................1-7 1.3.1. Profile of EPTZ3000/EPTZ3000I.....
ページ3に含まれる内容の要旨
3. EPTZ3000/EPTZ3000I CAMERA SETUP MENU ............................. 3-27 3.1. Structure of the Setup Menu ................................................................3-27 3.1.1. Camera Setup Menu ........................................................................3-28 4. EPTZ3000/3000I FUNCTION SETUP AND OPERATION ................ 4-36 4.1. Manual Control Mode............................................................................4-36 4.2. Auto Pan Mode .......................
ページ4に含まれる内容の要旨
1. EPTZ3000/EPTZ3000I OVERVIEW 1.1. Introduction EPTZ3000/EPTZ3000I, an intelligent high-speed dome camera is ready to secure your property with its omni-directional and exact monitoring. A 30X optical and 8X digital zoom combining with a high-performance chip makes captured images clear and vivid. The other powerful camera functions EPTZ3000/EPTZ3000I equips with: Wide Dynamic makes objects clear in a high illumination background. Vertical double density interline CCD with a slower
ページ5に含まれる内容の要旨
Furthermore, the micro control unit enables camera a nimble and exact movement from minimal 0.01°/sec to maximal 360°/sec. It can go to every preset position in 1 second. It also has other advantages such as: 192 preset positions are available. 16 cruise tours can be set, and each tour contains up to 16 positions. Up to 256 speed domes can be supported on a RS-485 bus when all speed domes are controlled by keyboard EKB500. Auto heater and fan to fit all kinds of temperature (outdo
ページ6に含まれる内容の要旨
1.2. Specifications Model EPTZ3000 (outdoor) EPTZ3000I (indoor) Pickup Device 1/4'' Vertical double density interline CCD Video Format NTSC or PAL Scanning System NTSC: 525 TV lines, 60 fields/sec PAL: 625 TV lines, 50 fields/sec Picture Elements 768 x 494 ( NTSC ) , 752 x 582 ( PAL ) Horizontal Resolution 520 TVL:Color ; 570TVL:B/W Sensitivity 0.3 Lux/F=1.6 Color ; 0.05 Lux/F=1.6 B/W S/N Ratio Over 52dB Electronic Shutter 128x (Slow Shutter ON)~1/60~1/120,000 sec (NTSC) 128x (Slo
ページ7に含まれる内容の要旨
Dwell Time (2 points) 1~127 seconds available Preset Positions 128 positions Running to Position Speed 1~239 grades available Dwell Time at Preset 1~239 seconds available Position Tour 16 groups Tour Point per Group 16 preset positions Fan & Heater Fan & Heater auto starts No ±0.1° Position Accuracy Alarm 4 in 1 out with tour/position auto triggering Built-in Menu for Yes Functions Communication RS-485 Communication Speed 1200/2400/4800/9600 bps Built-in Protocols EVF-1 ; Pelco-P
ページ8に含まれる内容の要旨
1.3. Feature 1.3.1. Profile of EPTZ3000/EPTZ3000I EPTZ3000 Wall Mount Bracket M5 Bolt (Hex) x3 Base PCB board Control board Connection Bus Housing Power Cable Inner Housing BNC Cable RS485 Cable M3 Bolt x3 Mechanical Part Bulb Camera Module EPTZ3000I Power Cable Base PCB board BNC Cable RS485 Cable Control board Housing Clip Connection Bus Mechanical Part Ceiling Button Camera Module Bulb 1-7
ページ9に含まれる内容の要旨
1.3.2. EPTZ3000/EPTZ3000I Base Board The base board that is on the bottom of the housing connects to power cable, video cable, control cable, alarm cable, fan and heater. In order to connect to cables, the board needs to be taken off, and put back after finishing connecting to all cables. The connectors of cable names are marked on the board in white text. The details of the alarm connector (JP5) are shown on the APPENDIX A. For EPTZ3000 outdoor model, JP1, JP3 and JP6 that are two-pin con
ページ10に含まれる内容の要旨
ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 1.3.3. EPTZ3000/EPTZ3000I Control Board The PCB board with two dipswitches is the control board of EPTZ3000/EPTZ3000I. The two switches are used to set address, protocol, Baud Rate, video format and terminal resistance. CPU SW2 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 SW1 1-9 BAUD Protocol
ページ11に含まれる内容の要旨
1.4. EPTZ3000/EPTZ3000I Connection 110V AC 24V AC POWER 24V AC / 3.5 A Adapter BNC Video Out Ω 1.0Vpp ± 0.2V, 75 RS485 Tx(+) RS485 Control Line RS485 Tx(-) EPTZ3000/ Alarm 1 EPTZ3000I Alarm 2 Alarm 3 4 ALARM INPUTS Alarm 4 GROUND ALARM OUTPUTS N.C. N.O. COM 1-10
ページ12に含まれる内容の要旨
1.5. EPTZ3000/EPTZ3000I Quick Operation Guide (Work with EKB500) EPTZ3000/EPTZ3000I and EKB500 (Keyboard) can work together by using factory default setting. You just need to connect cables by the following steps: 1. Connect the RS-485 cable to EPTZ3000/EPTZ3000I and a keyboard (EKB500). 2. Connect a video cable from EPTZ3000/EPTZ3000I to a monitor. 3. Connect the power to the EPTZ3000/EPTZ3000I and a keyboard (EKB500). After the EPTZ3000/EPTZ3000I finishes the self-test mode, you can star
ページ13に含まれる内容の要旨
2. EPTZ3000/EPTZ3000I INSTALLATION 2.1. Packing List There are 3 boxes that are housing, bulb and mechanical part with a camera module, one wall mount bracket, one power adapter and one tool packet in the package. The detail accessories list below: Housing x1 Bulb x1 Mechanical part with a camera module x1 Wall mount bracket x1 Adapter x1 Tool packet Glove x2 M5 Hex Allen wrench x1 Pin connector x1 M5 screw (Hex) x3 for wall mount bracket fixing M3 screw x3 f
ページ14に含まれる内容の要旨
Video Cable A BNC cable is used for connecting an EPTZ3000/EPTZ3000I to a DVR or a monitor. An amplifier may be needed if the video cable is too long. Control Cable Basically, EPTZ3000/EPTZ3000I uses a differential pair to connect to other devices by cascading. A cable that has low signal decline can be used as a control cable. Alarm Cable An alarm cable is not included in the packing list. A suitable wire that has low signal decline can be used as an alarm cable. 2.3. Initial Set
ページ15に含まれる内容の要旨
ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 2.3.1. Address Setting The address code of the EPTZ3000/EPTZ3000I should be set to correspond properly with a control device to control multiple dome cameras. The address codes are made up by the dipswitch SW1 (8 bits) on the PCB board. The 8 bits dipswitch indicates the 8 binary coded of the address, and there are 256 addresses can be selected (0 ~ 255, 2 = 256). It also means that there are up to 256 dome cameras that can cascade on the RS-485 bus. T
ページ16に含まれる内容の要旨
Switch Address S S Sw w wiiit t tc c ch h h A A Ad d dd d dr r re e es s ss s s S S S Sw w w wiiiit t t tc c c ch h h h A A A Ad d d dd d d dr r r re e e es s s ss s s s S S S S Sw w w w wiiiiit t t t tc c c c ch h h h h A A A A Ad d d d dd d d d dr r r r re e e e es s s s ss s s s s ON ON ON ON 0 32 64 96 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON ON ON ON 1 33 65 97 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON ON ON ON 2 34 66 98 1 2 3 4 5 6 7 8 1
ページ17に含まれる内容の要旨
Switch Address S S Sw w wiiit t tc c ch h h A A Ad d dd d dr r re e es s ss s s S S S Sw w w wiiiit t t tc c c ch h h h A A A Ad d d dd d d dr r r re e e es s s ss s s s S S S S Sw w w w wiiiiit t t t tc c c c ch h h h h A A A A Ad d d d dd d d d dr r r r re e e e es s s s ss s s s s ON ON ON ON 128 160 192 224 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON ON ON ON 129 161 193 225 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON ON ON ON 130 162 194 226 1 2
ページ18に含まれる内容の要旨
ON ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 2.3.2. Communication Protocol Setting st nd rd The 1 , 2 and 3 bits of the SW2 are used to set communication protocol. The factory default protocol is EVF. PELCO-D A-TYPE EVF AUTO PELCO-P SW2 PLUS-D Protocol Baud Rate Terminal Resistance Notice: Please make sure the power is off
ページ19に含まれる内容の要旨
Notice: Please make sure the power is off before setting, and restart the EPTZ3000/EPTZ3000I to enable a new value after changing. 2-18
ページ20に含まれる内容の要旨
2.4. Rack and Speed Dome Installation 2.4.1. Installation Requirements 1. Installation should be handled by a qualified service agent and should comply with all local regulations. Service personnel should expect potential problems such as surface strength, surface material, falling objects, outer breaches, building vibration or other similar conditions. 2. Check for all necessary materials, and ensure if the selected installation location is suitable for the EPTZ3000/EPTZ3000I. 2.4.2.