ページ1に含まれる内容の要旨
Programming g uide
Xr 500 Serie S Canadian
Command Pro Ce SSor™ Panel
ページ2に含まれる内容の要旨
MODEL XR500 SERIES CANADIAN ACCESS CONTROL COMMAND PROCESSOR™ PANEL PROGRAMMING GUIDE Contains programming Instructions for use with the Model XR500, XR500N, XR500E Canadian Access Control Command Processor™ Panels. When using the XR500 Series Canadian panel for any ULC other listing organization’s approved methods, refer to this manual and the XR500 Series Canadian Installation Guide (LT-0681CAN). These documents outline the installation and programming requirements of all applications for
ページ3に含まれる内容の要旨
Table o f Con Ten TS 1.1 Before you Begin ................................................................. 1 Programming Information Sheet ........................................... 1 1.2 Getting Started .................................................................... 1 1.3 Encrypted Communications (XR500N/XR500E only) ................ 2 1.4 Programmer Operation ......................................................... 2 1.5 Programmer Lockout Codes ........................................
ページ4に含まれる内容の要旨
Table of Con Ten TS 4.3 Gateway Address ................................................................13 4.4 Subnet Mask ......................................................................13 4.5 DNS Server ........................................................................13 4.6 Passphrase (XR500E only) ...................................................13 Messaging Setup .............................................................14 5.1 Messaging Setup ...............................
ページ5に含まれる内容の要旨
Table o f Con Ten TS 7.5.2 Encrypt Network Remote .....................................................23 7.6 Allow Cellular Remote .........................................................23 7.6.1 First GPRS APN / Second GPRS APN .....................................23 7.6.2 Encrypt Cellular Remote ......................................................23 7.7 Allow RS-232 Remote ..........................................................23 7.8 Entré Connection ....................................
ページ6に含まれる内容の要旨
Table of Con Ten TS Output Options................................................................33 11.1 Output Options ...................................................................33 11.2.1 Cutoff Output ....................................................................33 11.2.2 Output Cutoff Time .............................................................33 11.3 Communication Trouble Output ............................................33 11.4 Fire Alarm Output ....................
ページ7に含まれる内容の要旨
Table o f Con Ten TS 17.9 User Command Reports.......................................................42 17.10 Door Access Reports ...........................................................43 17.11 Supervisory Reports ............................................................43 17.12 PC Log Real-Time Status .....................................................43 Area Information ............................................................44 18.1 Area Information ...............................
ページ8に含まれる内容の要旨
Table of Con Ten TS 19.13 Alarm Action.......................................................................56 19.14 Disarmed Open .................................................................56 19.15 Report to Transmit ..............................................................57 19.16 Output Number ..................................................................57 19.17 Output Action .....................................................................57 19.18 Swinger Bypass .......
ページ9に含まれる内容の要旨
This page intentionally left blank. XR500 Series Canadian Programming Guide Digital Monitoring Products vii
ページ10に含まれる内容の要旨
i n Todur CTion Introduction 1.1 Before you Begin This guide provides programming information for the DMP XR500, XR500N, and XR500E Command Processor™ Panel. After this Introduction, the remaining sections describe the functions of each programming menu item along with the available options. Before starting to program, we recommend that you read through the contents of this guide. The information contained here allows you to quickly learn the programming options and operational capabiliti
ページ11に含まれる内容の要旨
i n Todur CTion 1.3 Encrypted Communications (XR500N/XR500E only) Some installations require secure data communications. DMP offers NIST approved AES encrypted communication. Use a unique passphrase to enable encrypted communications and provide a secure means for data communications. See Network Options. An XR500E panel communicates using AES encryption. If you currently have an XR500N panel installed, you may purchase a separate feature key to activate encrypted communications us
ページ12に含まれる内容の要旨
i n Todur CTion 1.7 Power Up When the XR500 Series Canadian panel is powered up after an AC power failure, any zone transitions are not recognized for 60 seconds. Normal zone processing resumes at the end of the 60 seconds. 1.8 Keypads DMP offers multiple keypads in a variety of styles. All DMP keypads provide the same programming capabilities. Each keypad and its operation are shown and described in the following sections. 32-Character Display 32-Character Dis
ページ13に含まれる内容の要旨
i n Todur CTion 1.10 Entering Alpha Characters Some options during programming require you to enter alpha characters. To enter an alpha character, press or touch the key that has that letter written below it. The keypad displays the number digit of the key . Next, press the Select key/area that corresponds to the loca tion of the letter under the key . P ressing a different Select key/area changes the letter . When an other digit key is pressed, the last lett
ページ14に含まれる内容の要旨
i n Todur CTion 1.13 Multiple Displays For many programming and user options, such as Area selections, Menu Displays, and Status Lists, there are several displays containing programming. For example, when programming Menu Displays, keypads 1 through 16 display on two separate displays. First, keypads 1 through 8 display . P ress the COMMAND key to display keypads 9 through 16. This same scheme is used for areas 1 through 32. Note : Areas not pre-programmed at insta
ページ15に含まれる内容の要旨
i ni Tializa Tion Initialization NOTE: WHEN ANY PANEL PROGRAMMING IS CHANGED, THE STOP ROUTINE MUST BE RUN AND ‘SAVING PROGRAM’ MUST DISPLAY ON THE KEYPAD IN ORDER TO SAVE THE PROGRAMMING CHANGES. SEE SECTION 17.1. INITIALIZATION 2.1 Initialization This function allows you to clear selected parts of the panel program back to the factory defaults in preparation for system programming. Run the initialization function on all new installations. For each section of the panel program you can in
ページ16に含まれる内容の要旨
i ni Tializa Tion COM/RMT? NO YES 2.9 Clear Communication and Remote Options NO - Leaves existing communication and remote options intact. SURE? YES NO YES - Clears communication and remote options programming to factory defaults. DEFAULTS NO YES 2.10 Set to Factory Defaults SURE? YES NO NO - Leaves existing panel programming intact. YES - Sets the remainder of the panel programming back to the factory defaults. Note: Sets the Programming and User language to English. XR500 Series
ページ17に含まれる内容の要旨
Communi Ca Tion Communication 3.1 Communication COMMUNICATION Configure the communication options for the panel. The information you program varies with the Communication Type you select. 3.2 Account Number ACCOUNT NO: 12345 The Account Number is a 1 to 5 digit number used to identify which panel is sending a message. Enter the account number sent to the SCS-1R R eceiver . Messages may be sent to a central station or via PC Log R eports to a PC. The defa
ページ18に含まれる内容の要旨
Communi Ca Tion 3.6 Path Type PATH TYPE: BACKUP The P ath T ype defines if the path is P rimary or Backup. Because P ath 1 is P rimary , PRIMARY BACKUP this prompt only displays for paths 2-8. Default is Backup. Note: If the P rimary Communication T ype is CELL, then the backup Communication Type can only be NET or 232. 3.7 Test Report TEST RPT: YES Test Report determines if test reports are sent on this path. Reports are sent NO YES DEFER according to the pro
ページ19に含まれる内容の要旨
Communi Ca Tion 3.15 Receiver Port RECEIVER PORT - Enter the receiver port number . V alid range is 1 to 65,535. Default is 2001. 2001 3.16 First Telephone Number FIRST PHONE NO. This option displays only if the Communication Type is DD or CID. This is the first number the panel dials when sending reports to the receiver . P hone numbers can have two lines of 16 characters each to equal up to 32 characters. Enter P to program a three-second paus
ページ20に含まれる内容の要旨
Communi Ca Tion RETRY SECONDS: 6 3.22 Retry Seconds This option displays for NET or 232 Communication Types. Enter the number of seconds (between 6 and 15) the panel should wait before retrying to send a message to the receiver if an acknowledgment was not received. The panel retries as many times as possible for a period of one minute before sending a network trouble message. For example, if retry time is set to 15, the panel retries four times. The default R etry