ページ1に含まれる内容の要旨
UHI-SBG-0 Indoor Housing
en Installation Manual
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
| en iii 10.Power Sources - Operate the unit only from the type of power source Important Safeguards indicated on the label. If unsure of the type of power supply to use, 1. Read, Follow, and Retain Instructions - All safety and operating contact your dealer or local power company. instructions should be read and followed before operating the unit. • For units intended to operate from battery power, refer to the Retain instructions for future reference. operating instructions. 2. Heed Wa
ページ4に含まれる内容の要旨
iv en | Safety Precautions CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates the presence of uninsulated “dangerous voltage” within the product’s enclo- sure that can cause an electric shock. This symbol indicates the presence of important operating and maintenance (servicing) instruc- tions in the literature accompanying the appli- ance. Installation should
ページ5に含まれる内容の要旨
UHI-SBG-0 Series v Preface This guide describes how to install the UHI-SBG-0 Series. Audience This guide is intended for qualified installation and service personnel who are familiar with the applicable national and local electrical codes. Document Conventions Convention Meaning Bold Denotes a part, item, or assembly. Italic Denotes a reference to another paragraph, figure or table. Underline Used to emphasize a point. courier Denotes the actual name of an object, the exact code that should be
ページ6に含まれる内容の要旨
vi UHI-SBG-0 Series Customer Support and Service If this unit needs service, contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions. Service Centers USA Phone: 800-366-2283 or 585-340-4162 Fax: 800-366-1329 Email: cctv.repair@us.bosch.com CCTV Spare Parts Phone: 800-894-5215 or 408-957-3065 Fax: 408-935-5938 Email: BoschCCTVparts@ca.slr.com Canada Phone: 514-738-2434 Fax: 514-738-8480 Europe, Middle East & Asia Pacific Region
ページ7に含まれる内容の要旨
UHI-SBG-0 Series vii 1 Unpacking..............................................................................................................................1 1.1 Parts List................................................................................................................................1 1.2 Tools Required .......................................................................................................................1 2 Exploded View.........................................
ページ8に含まれる内容の要旨
viii UHI-SBG-0 Series September 15, 2006 | F01U032279_01 Installation Manual Bosch Security Systems, Inc.
ページ9に含まれる内容の要旨
UHI-SBG-0 Series Unpacking 1 1Unpacking This equipment should be unpacked and handled with care. If an item appears to have been damaged in shipment, notify the shipper immediately. Verify that all the parts listed in the Parts List below are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. The original packing carton is the safest container in which to transport the unit and must be used if returning the unit for service. Save
ページ10に含まれる内容の要旨
2 Exploded View UHI-SBG-0 Series 2 Exploded View Reference Part 1Top cover 2 Camera tray 3 Connector block 4Plugs 5 Front window holder 6 NPT fittings 7 Adjustable head 8Mount head 9 J-mount base September 15, 2006 | F01U032279_01 Installation Manual Bosch Security Systems, Inc.
ページ11に含まれる内容の要旨
UHI-SBG-0 Series Description 3 3Description The UHI-SBG-0 Series is an indoor housing which meets customer demand for appearance, cost competitiveness, and easy installation. Removal of two tamper-resistant screws is all that is necessary to open the cover and access the camera and lens in its mounted position. Power and video cabling can be routed through liquid tight fittings in the rear or bottom of the hous- ing. Camera Ratings 1 0°C (32°F) - 50°C (122°F) Ambient temperature Power cons
ページ12に含まれる内容の要旨
4 Cable Requirements UHI-SBG-0 Series 4 Cable Requirements The specifications for the UHI-SBG-0 Series may vary depending on the model that you are operating. Refer to the following tables for more information. Video Transmission (coaxial) Type Specification Cable Type RG-59/U for runs < 300 m (1000 ft) RG-11/U for runs < 600 m (2000 ft) Cable Size Outside diameter between 4.6 mm (0.181 in.) -7.9 mm (0.312 in.) Cable Shape Round Shield > 93% Braided copper shield Center Conductor Stranded c
ページ13に含まれる内容の要旨
UHI-SBG-0 Series Installing the Housing 5 5 Installing the Housing This chapter outlines the procedures needed to install the UHI-SBG-0 Indoor Housing Series. Installation should be made by a qualified service person and all local codes should be con- formed to. 5.1 Opening the Cover The UHI-SBG-0 housing is secured with two (2) tamper-resistant screws. To open the cover, use the supplied tamper-resistant wrench to remove the screws. Fig. 5.1 Opening the Cover 5.2 Feed-through Wiring The UHI-
ページ14に含まれる内容の要旨
6 Installing the Housing UHI-SBG-0 Series Installing the NPT Fittings 1. Determine to use either the rear or bottom gland holes and remove the (2) rubber hole plugs. 2. Remove the screw inside the housing that holds the camera tray. Set screw aside. 3. Unlock and remove the tray by sliding it toward the rear of the housing. Set tray aside. 4. Attach the two (2) 1/2 in. NPT fittings with the rubber washer on the outside of the hous- ing directly to the rear hole openings (see Figure 5.4 on page
ページ15に含まれる内容の要旨
UHI-SBG-0 Series Installing the Housing 7 5.4 Wire Preparation Supply the UHI-SBG-0 with power by using a power cord that complies with the Nec 400-4 CEC rule 4-010 and is marked with INDOOR, W or W-A. For 24 V cameras, use the recom- mended maximum cable length chart for selecting the proper wire size. 2 Wire Size AWG Housing Distance Wire Size mm 0.5 20 27 m (90 ft) 1 18 42 m (140 ft) 1.5 16 67 m (220 ft) 2.5 14 108 m (355 ft) 4 12 172 m (565 ft) Table 5.1 Maximum cable lengths for 24 V cam
ページ16に含まれる内容の要旨
8 Installing the Housing UHI-SBG-0 Series 5.5 Attaching the Camera and Spacer to the Tray The UHI-SBG-0 includes two (2) spacers which may be required to keep the camera level (see Figure 5.7 on page 8). If a spacer is not used, the camera may dip down creating a port hole effect. Camera and Spacer Installation 1. Attach the lens to the camera. 2. Tentatively place the camera tray inside the housing. Do not secure. 3. Determine if one of the supplied spacers are required and place on top of t
ページ17に含まれる内容の要旨
UHI-SBG-0 Series Mounting the Housing 9 6 Mounting the Housing The UHI-SBG-0 housing includes a J-mount which features a removable camera bracket and locking grooves to keep the housing from drooping. The mount is vertically adjustable by pushing the housing up or down. Mounting Procedure 1. Determine a proper location for the housing. 2. Insert the coax and power lead wires from the wall through the supplied J-mount allow- ing enough slack to pull through the housing (see Figure 6.1 on page
ページ18に含まれる内容の要旨
10 Operation UHI-SBG-0 Series 6. Secure the housing to the mount by attaching two 1/4-20 x 0.50 in. screws and two 1/4 in. washers. The washers must be used for the screws to thread properly. NOTE! The outermost set of 1/4-20 threaded holes are for mounting to feed-through mounts and the innermost 1/4-20 holes are for mounting to all other mounts and pan/tilts (see Figure 1). For mounting to all other mounts and pan/tilts, refer to the specific device’s installation i guide. 6.1 Installing
ページ19に含まれる内容の要旨
Americas: Europe, Middle East, Asia: Asia-Pacific: Bosch Security Systems Bosch Security Systems B.V. Bosch Security Systems Pte Ltd. 130 Perinton Parkway P.O. Box 80002 38C Jalan Pemimpin Fairport, New York, 14450 5600 JB Eindhoven Singapore 577180 USA The Netherlands Phone +65 6319 3450 Phone +1 800 289 0096 Phone +31 (0) 40 27 83955 Fax +65 63139 3499 Fax +1 585 223 9180 Fax +31 (0) 40 27 86668 www.boschsecurity.com www.boschsecurity.us www.boschsecurity.com © Bosch Security Systems, Inc. 20