CONTENTS Section Page 1.0 GENERAL ..................................................................................................3 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ...............................3 2.0 DESCRIPTION ..........................................................................................4 2.1 MODELS ............................................................................................4 2.2 OPTIONAL ACCESSORIES .........................................................
ページ3に含まれる内容の要旨
1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by manuf
ページ4に含まれる内容の要旨
2.0 DESCRIPTION Environmental enclosures in the TC9346A Series are used with pan/tilt units or fixed mounts. The enclosures are constructed of aluminum. You can install cameras with either fixed focal length lenses or motorized zoom lenses. All models have an adjustable camera sled to accommodate different sizes of cameras and lenses. 2.1 MODELS TC9346A Environmental enclosure with rear-opening lid. Lid has gas spring to hold it open. 29-inch (73.66 cm) length. TC9346A-1 TC9346A with 120 VAC t
ページ5に含まれる内容の要旨
3.0 INSTALLATION 1. Unlatch and raise the enclosure lid. The gas spring will hold the lid in place when it is fully opened. 2. Remove the camera sled from the rail: a. Loosen the screws. b. Slide the sled so that the screws are in the large part of the mounting slots. c. Remove the sled. d. Remove the parts tied to the sled. 3. TC9346A-1, -2, -3 Models Only If you are installing the enclosure in a marine or high-moisture environment, make the following modifications to your enclosure: Refer to
ページ6に含まれる内容の要旨
c. Remove the four screws and washers (B and D) that secure the fan to the fan plate. d. Turn the fan around so that it blows toward the viewing window (refer to the arrows on the fan). e. Reinstall the fan on the fan plate. f. Reinstall the fan plate and fan in the enclosure. g. Reconnect the electrical plug on the fan. h. Close the enclosure lid. i. On the bottom of the enclosure, remove the vent grill (1) and filters (2) at the front of the unit. Replace the grill with one of the vent covers
ページ7に含まれる内容の要旨
b. Wire the 10-connector INPUTS terminal on the circuit board to the lens controller as follows: • Lens Common - Connector 1 • Focus - Connector 2 • Zoom - Connector 3 • Iris - Connector 4 • Preset Common - Connector 5 • Preset Focus - Connector 6 • Preset Zoom - Connector 7 • Preset High - Connector 8 11. TC9346A-1, -2, -3 Models Only Refer to Figure 2 and connect the camera’s power input to the circuit board. There are two ways to supply power to the camera - when the power require- ments for
ページ8に含まれる内容の要旨
13. TC9346A-1, -2, -3 Models Only Wire power to the enclosure to operate accessories (and the camera if its power is connected to CAM 1 on the circuit board) as follows: a. Remove the plastic cover over the power supply section of the circuit board. b. Connect AC high to AC HI of the 3-connector terminal block. c. Connect AC neutral to AC NT of the 3-connector terminal block. d. Connect ground to GND of the 3-connector terminal block. e. Reinstall the plastic cover over the power supply section
ページ9に含まれる内容の要旨
Figure 2. TC9346A Series Input Wiring Diagram 9 KIT # BK57-2 KIT # BK57-1 (120 V) FAN KIT # BK57-3 (230 V) 24 VDC FAN RED PLUG 1 BLK 120/230 V 2 KIT # WD57-1 DEFROSTER 3 KIT # WD57-2 4 24/120/230 V KIT # WD57-3 PCB9000277ASSY HEATER HEATER 24/120/230 V 24/120/230 V KIT # HK57-1 RED KIT # WW57-1, -3 1 2 KIT # HK57-2 BLK BLU 1 PLUG TO SWITCH FROM -1, TO -3, PLUG 2 KIT # HK57-3 WHT USE JUMPER ON PC BOARD BLK 1 2 PLUG BLK PCB9000275 BLK/WHT BLU 120/230 VAC BLU/WHT M 1 2 3 4 BRN PLUG BRN/WHT S
ページ10に含まれる内容の要旨
Table A. 24 VAC Wiring Distances The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.) EXAMPLE: An enclosure that re- Wire Gauge quires 80 vA and is installed 35 feet 20 18 16 14 12 10 (10 m) from the transformer would 10 283 451 716 1142 1811 2880 require a minimum wire gauge of (86) (137) (218) (348) (551) (877) 20 AWG. 20 141 225 358 5
ページ11に含まれる内容の要旨
4.0 OPERATION If your enclosure has a thermostatically controlled blower, the thermostat is set to turn the fan on between 77° and 93°F (25° and 34°C) and to turn the fan off be- tween 62° and 78°F (17° and 26°C). If your enclosure has thermostatically controlled heaters or defroster, the thermo- stat is set to turn them on between 42° and 58°F (6° and 14°C) and to turn them off between 72° and 88°F (22° and 31°C). 11
ページ12に含まれる内容の要旨
5.0 MAINTENANCE AND TROUBLESHOOTING 5.1 MAINTENANCE Perform the following maintenance at regularly scheduled intervals to prolong the operational life and appearance of the equipment. 1. Clean the window with a mild non-abrasive detergent in water and a soft cloth to maintain picture clarity. 2. If your enclosure has a blower, clean the foam filters as follows: a. On the bottom front of the enclosure, remove the two screws in the vent grill. b. Remove the vent grill and take out the filters. c
ページ13に含まれる内容の要旨
ENCLOSURE CIRCUIT BOARD REFER TO FIGURE 3 FOR COMPONENT LOCATIONS Figure 5. Wiring Diagram for Optional Circuit Board (O/I-PCB) 13
ページ14に含まれる内容の要旨
6.0 SPECIFICATIONS ELECTRICAL Input Voltage: 24, 120 or 230 VAC, 50/60 Hz Electrical Connections: One each of the following when equipped with optional circuit board (O/I-PCB): 3-connector terminal block for power input 6-pin lens connector 9-connector terminal block for lens wiring 10-connector terminal block for camera/lens wiring 2-connector terminal block for spare connections 3-pin socket for camera power input 2-pin socket for optional camera power input 2-pin socket for blower 2-pin sock
ページ15に含まれる内容の要旨
GENERAL NEMA Rating: 3R (4 when vent cover plates are used) iec 144 rating: IP32 (IP56 when vent cover plates are used) Environment: Indoor/outdoor -10° to 120°F (-23° to 49°C) (Design and product specifications subject to change without notice.) C 10.55 (26.79) 5.25 (13.35) 4.25 6.19 (10.79) (15.72) 3.06 (7.78) 8.60 A (21.84) AB C 29.00 14.50 32.50 (73.66) (36.83) (82.55) B NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES Figure 6. TC9346A Dimension Drawing 15
ページ16に含まれる内容の要旨
Bosch Security Systems, Inc. Bosch Security Systems B.V. Bosch Security Systems Pte Ltd. 850 Greenfield Road P.O. Box 80002 38C Jalan Pemimpin Lancaster, PA 17601 USA 5600 JB Eindhoven Singapore 577180 Tel: 800-326-3270 The Netherlands Republic of Singapore Fax: 1-717-735-6560 Tele +31 40 27 80000 Tel: 65 (6) 319 3486 www.boschsecuritysystems.com © 2004 Bosch Security Systems GmbH 3935 890 12912 04-33 | Updated August 10 2004 | Data subject to change without notice.