ページ1に含まれる内容の要旨
FMR-7036
Installation Instructions
EN Fire Annunciator Keypad
ページ2に含まれる内容の要旨
FMR-7036 | Fire Annunciator Keypad | Contents Contents Contents ...........................................................................2 1.0 Notice .................................................................3 2.0 Device Description..........................................3 3.0 Installing the Reference Card.......................3 4.0 Mounting the FMR-7036.................................3 4.1 Surface Mounting...............................................3 4.2 Electrical Box
ページ3に含まれる内容の要旨
FMR-7036 | Fire Annunciator Keypad | 1.0 Notice . Install the reference card before securing 1.0 Notice the keypad. These instructions cover the installation of the Bosch Security Systems, Inc. FMR-7036 Fire Annunciator Keypad in a fire system supervised by a Bosch FPD- Figure 2: Reference Card Installation 7024 Fire Alarm Control/Communicator. Install, test and maintain the FMR-7036 according to FMR-7036 Reference Card 2 these instructions, NFPA 72, local codes, and the authority
ページ4に含まれる内容の要旨
FMR-7036 | Fire Annunciator Keypad | 5.0 Setting the FMR-7036 Address 5.0 Setting the FMR-7036 Figure 3: Mounting Hole Locations Address 3 Each keypad must have its address set with its address pins. The keypads must 1 also be programmed at the control panel. 4 Figure 5: FMR-7036 Address Jumper Settings 3 2 2 Address 1 Address 2 Address 3 1235 4 678 1235 4 678 1235 4 678 Address 4 Address 5 Address 6 Back of FMR-7036 Keypad 3 1235 4 678 1235 4 678 1235 4 678 3 Address 7 Address 8 A
ページ5に含まれる内容の要旨
FMR-7036 | Fire Annunciator Keypad | 7.0 FMR-7036 Programming . 8. Press [2] to select 2-AUTHORITY LEVEL. Up to three keypads may be used on any 9. Press [2] to select 2-MEDIUM. single 1,000 ft. (305 m) run of #18 AWG (1.2 mm) wire. 10. Press [*] to exit programming mode. 11. Test all FMR-7036 functions. Bring the wiring through the wire entrance in the keypad’s base. Connect the wiring to the keypad’s A PIN is required for remote devices to connector. Refer to Figure 4 on page 4. e
ページ6に含まれる内容の要旨
FMR-7036 | Fire Annunciator Keypad | 8.0 FMR-7036 Operation 8.2 Reset Using the Keylock Switch to lockout the FMR-7036 will prevent any user from The Reset key is used to reset the control panel after silencing or resetting alarms, including an alarm has occurred. Any sounders or NACs that emergency personnel such as the police or are activated will silence, and smoke detector zones fire department. Check with the local will remove power briefly to reset detectors. Authority Havin
ページ7に含まれる内容の要旨
FMR-7036 | Fire Annunciator Keypad | 9.0 Troubleshooting . 9.0 Troubleshooting Refer to Table 2 when troubleshooting the FMR-7036. Table 2: FMR-7036 Troubleshooting Tips Keypad Notification Possible Causes Continuous keypad sounder The yellow and green wires PLUS ""System Fault"" have been disconnected. display The keypad has not been programmed at the control panel. The control panel has malfunctioned. Control panel does not The keyswitch is in LOCK respond to keypad input. p
ページ8に含まれる内容の要旨
Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 (800) 289-0096 www.boschsecurity.com © 2008 Bosch Security Systems, Inc. F01U010584-01