BUILT-IN STRUCTURE BUILT-IN STRUCTURE CUTOUT DIMENSIONS SLEEVE DIMENSIONS All dimensions are to finished surfaces. WIDTH A HEIGHT B C DEPTH Figure 3 .625 TYP. TRIM BUILT-IN CUTOUT DIMENSIONS OVERHANG Side Figure 5 475 675 Burner Tolerances 3 5 5 3 + ⁄16” BUILT-IN INSULATED SLEEVE A31 ⁄8”43 ⁄8”10 ⁄4” - 0 DIMENSIONS 3 1 1 1 + ⁄32” B21 ⁄8”21 ⁄8”4 ⁄2” - 0 475 675 Tolerances 3 + ⁄16” C 25” 25” 24” 1 1 1 + ⁄4” -0 A31 ⁄2”43 ⁄2” - 0 WT 240 285 40 3 1 1 + ⁄16” B21 ⁄16”21 ⁄16” - 0 Weight (expressed in po
ページ3に含まれる内容の要旨
BUILT-IN SLEEVE GAS VENTILATION LINE LOCATIONS Note: These drawings are only a reference. Front of sleeve Support tubes Plan view View of left side View of right side Figure 7 B A Support tubes Front of sleeve C Right side view Figure 6 BUILT-IN SLEEVE GAS LINE LOCATIONS 475 675 Tolerances View of front side View of back side 1 + ⁄16 A 5.0” 5.0” 1 Figure 8 - ⁄16 1 + ⁄16 B 10.1” 10.1” 1 n Cross ventilation must be incorporated in the - ⁄16 1 supporting structure. We recommend a minimum of + ⁄32 C
ページ4に含まれる内容の要旨
Gas line piping TYPICAL GAS SUPPLY n If the length of line required does not exceed 50 feet, INSTALLATION use a 5/8" O.D. tube. One size larger should be used for lengths greater than 50 feet. WE RECOMMEND THAT THIS INSTALLATION BE DONE BY A LICENSED PROFESSIONAL. n Gas piping may be copper tubing, type K or L; polyethylene plastic tube, with a minimum wall General Specifications for Piping thickness of .062 inch; or standard weight (schedule Note - Contact your local municipality for building 4
ページ5に含まれる内容の要旨
ページ6に含まれる内容の要旨
BUILT-IN STRUCTURE BUILT-IN STRUCTURE CUTOUT DIMENSIONS SLEEVE DIMENSIONS WIDTH All dimensions are to finished surfaces. A B HEIGHT C DEPTH Figure 3 Figure 5 BUILT-IN CUTOUT DIMENSIONS BUILT-IN INSULATED SLEEVE Side Burner Tolerances 3 DIMENSIONS + ⁄16” 3 A10 ⁄4” - 0 Side burner Tolerances 3 1 + ⁄32” B4 ⁄2” 1 - 0 19 + ⁄4” A10 ⁄32” 3 - 0 + ⁄16” C 24” 1 -0 9 + ⁄8” B4 ⁄64” - 0 WT 40 1 25 + ⁄4” C23 ⁄32” -0 Weight (expressed in pounds) represents the total weight WT 40 of the sleeve and the cooking u
ページ7に含まれる内容の要旨
24 inches 6 inches BUILT-IN CONSTRUCTION GENERAL INFORMATION CLEARANCE FROM COMBUSTIBLE SURFACES OR WARNING STRUCTURES AWeber-Stephen Products Co. factory Warning: Clearance from the outside walls of the installed sleeve must be used for any sides and back of the sleeve must be a minimum of built-in installation. 24 inches from a combustible surface. Measure from the outside wall of the sleeve to the combustible LOCATING YOUR SIDE BURNER surface. Figure 2. Refer to “Install Gas Supply” on page
ページ8に含まれる内容の要旨
n A manual shut-off valve must be installed outdoors, BUILT-IN SLEEVE GAS and be accessible, not in the “built-in” structure. An LINE LOCATIONS additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line. CAUTION: If young children are in the area, a locking valve should be considered. n Pipe compound should be used which is resistant to the action of natural gas when gas connections are made. n The gas connections must be f