In-LineLinc™ Dimmer
®
INSTEON Remote Control In-Line Dimmer
Owner’s Manual (rev 5.1+)
(#2475D)
Page 1 of 13 2475D - Rev: 1/21/2014 7:17 AM
ページ2に含まれる内容の要旨
In-LineLinc Dimmer – Features and Benefits ........................................................................................... 3 Features..................................................................................................................................................... 3 What’s in the Box? ..................................................................................................................................... 4 Preparing to Install In-LineLinc ............
ページ3に含まれる内容の要旨
In-LineLinc Dimmer – Features and Benefits Congratulations on purchasing the high-quality INSTEON In-LineLinc Dimmer Switch. With this easy- install module, you can add conveniently hidden, fully-dimmable remote control to not only the lights wired to In-LineLinc, but also other INSTEON devices. Features - Quick setup links to other INSTEON devices in minutes - Controls all incandescent lights up to 300 watts - Customize with 32 brightness levels and 4 ramp rates - Also compatible with lo
ページ4に含まれる内容の要旨
What’s in the Box? - In-LineLinc Dimmer - Quick Start Guide - Two (2) mounting screws - Three (3) wire nuts Preparing to Install In-LineLinc CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference. This product is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada. Use indoors only. This product is not
ページ5に含まれる内容の要旨
6) Referring to the diagram at right and the table below, use the included wire nuts to connect the fixture’s Line, Load, Neutral and Ground wires to In-LineLinc’s corresponding wires. In-LineLinc Wire Wall Box Wires Ground Bare copper (commonly bare copper, green wire or green screw) Neutral White (commonly white wire bundle) Load Red (light, fan, etc.) Line Black (100 - 277V to Ground) 7) Enable power to the switch from the circuit breaker or fuse panel. 8) Use In-LineLinc’s
ページ6に含まれる内容の要旨
Linking In-LineLinc Dimmer as an INSTEON Responder Be sure to link In-LineLinc Dimmer to an INSTEON controller before you finish installing the fixture. Refer to your controller device’s Quick Start Guide or Owner’s Manual to properly link it to In-LineLinc. Most controllers use the procedure below: 1) Put your controller into linking mode. For most INSTEON controllers, press and hold the Set button for 3 seconds or the On/scene button for 10 seconds. You will have 4 minutes to complete
ページ7に含まれる内容の要旨
When setting the ramp rate, the speed is determined using the load’s brightness level. Refer to the table below while programming to set the desired ramp rate: 1) Using either the local ON and OFF buttons or a controller (if In-LineLinc Dimmer is already linked to one), adjust the load wired to In-LineLinc Dimmer to the brightness level that corresponds with your desired ramp rate: Brightness Level Ramp Rate (seconds) 90-100% 0.1 77-87% 0.2 65-74% 0.3 52-61% 2 39-48% 2 26-35% 4.5 13-
ページ8に含まれる内容の要旨
Factory Reset Factory Reset clears all user settings from In-LineLinc Dimmer, including INSTEON scenes, on-levels, ramp rates, X10 addresses, etc. 1) Make sure In-LineLinc Dimmer is unlinked from all controllers. 2) Turn off the breaker supplying power to In-LineLinc Dimmer’s fixture. 3) Wait 10 seconds. 4) Push in Set button and hold it. While continuing to hold in the Set button, have a partner turn on the circuit breaker. 5) Release the Set button. A few seconds will pass, then In
ページ9に含まれる内容の要旨
Specifications General Product Name In-LineLinc Dimmer Brand INSTEON Manufacturer Product Number 2475D, INSTEON In-LineLinc Dimmer UPC 689076402743 Protected under U.S. and foreign patents (see Patent Number www.insteon.com) Warranty Two years, limited Operation On-Levels 32 locally, increments of 1% with software Ramp Rates 0.1 to 9 seconds, up to 9 minutes with software LED Indicator Off when load is on and vice versa Operation Modes INSTEON only, X10 only, INSTEON and X10 combo
ページ10に含まれる内容の要旨
Voltage 120 volts AC +/- 10%, 60 Hertz, single phase 6", 16 AWG, stranded,600V, 105°C insulation, ends stripped Power Wire Leads and tinned, LINE (black), LOAD (red), NEUTRAL (white) Ground Lead 6”, 18 AWG, stranded, bare copper Maximum Dimmer Load 600 watts (uses 12-Amp triac dimmer) Maximum Amps 2.5 amps Standby power consumption 0.78 watts Certifications Safety tested for use in USA and Canada (ETL #3017581) X10 Features X10 Primary Address 1 optional (comes unassigned) X10 Status
ページ11に含まれる内容の要旨
interference with older X10 BoosterLinc technology. Upgrade to INSTEON-compatible BoosterLinc modules (#4827). In-LineLinc doesn't The INSTEON controller may Relink In-LineLinc to the INSTEON controller. always respond to an have been reset without first See Adding In-LineLinc Relay as an INSTEON INSTEON controller. unlinking In-LineLinc from it. Responder. Install a powerline signal blocker in your home to keep X10 signals from neighboring homes Another controller, a timer or from
ページ12に含まれる内容の要旨
controller. Turn off the circuit breaker and try reinstalling After wiring in In- In-LineLinc is issuing an error In-LineLinc. If you are still experiencing an LineLinc, the unit lets out beep because the unit is wired error beep, consult an electrician to help you a continuous beep. incorrectly. install In-LineLinc. Replace your AFCI with a less sensitive brand or model from a hardware store with a customer-friendly return policy. In-LineLinc modules do not trip when used with the
ページ13に含まれる内容の要旨
Certification and Warranty Certification This product has been thoroughly tested by ITS ETL SEMKO, a nationally recognized independent third-party testing laboratory. The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U.S. and Canadian device safety standards, that the manufacturing site has been audited, and that the manufacturer has agreed to a program of quarterly factory follow- up inspections t