ページ1に含まれる内容の要旨
B3
ESTATE SERIES
MASTER / SLAVE SYSTEMS
MODEL SL 1000-B3, SW 2000-B3 & BG 3000-B3
SLIDE, SWING, AND BARRIER GATE OPERATORS
MODEL SL 1000-B3
MODEL BG 3000-B3
MODEL SW 2000-B3
ページ2に含まれる内容の要旨
TABLE OF CONTENTS SAFETY SUMMARY ............................................................................................................................1 BASIC INSTALLATION HINTS AND RULES......................................................................................2 PART 1 MASTER/SLAVE OPERATION............................................................................................3 A. WHAT IS MASTER/SLAVE OPERATION?...........................................................
ページ3に含まれる内容の要旨
TABLE OF FIGURES Figure 1. Master/Slave Gate Configurations........................................................................................................3 Figure 2. Typical Bi-Parting Gate Installation. .....................................................................................................4 Figure 3. Typical Bi-Parting Latch Gate Installation.............................................................................................5 Figure 4. Typical Trap Gate Insta
ページ4に含まれる内容の要旨
SAFETY SUMMARY It is important for everyone involved in the installation and operation of the LiftMaster models SL 1000, SW 2000, and BG 3000 Master/Slave systems to read the following warnings. WARNING! • A vehicle gate is a large, heavy object that is moved by an electric motor. A moving gate can cause serious injury or death! The safety and well-being of others depends on the installation of a safe system. • READ AND FOLLOW ALL INSTRUCTIONS. Improper installation of a gate operator can res
ページ5に含まれる内容の要旨
BASIC INSTALLATION HINTS AND RULES READ THIS SECTION CAREFULLY BEFORE BEGINNING YOUR INSTALLATION 1. UNDERSTAND THE SYSTEM AND INSTALLATION SITE THOROUGHLY. The B3 series are flexible and reliable gate operator systems, but the quality of service depends directly on the quality of installation. Please read these instructions and the Installation and Operation instructions for each gate operator carefully. Study the applicable diagrams before planning your installation. In particular, underst
ページ6に含まれる内容の要旨
PART 1 MASTER/SLAVE OPERATION A. WHAT IS MASTER/SLAVE OPERATION? The easy way to understand master/slave operation is by the computer terms “smart” and “dumb”. • “Smart” machines are controlled by a computer or dedicated microprocessor, such as microwave ovens and new-style washing machines. • “Dumb” machines are controlled by simple electronic or physical mechanisms, like old-style washing machines with their cams and timers. When your installation requires using two gates together, they can b
ページ7に含まれる内容の要旨
C. MASTER/SLAVE INSTALLATION DETAILS 1. BI-PARTING GATE DETAILS The simple Bi-Parting Gate is typically used in low traffic residential sites due to its ease of use. The Bi- Parting configuration can consist of any combination of models SL 1000-B3 (slide gate), SW 2000-B3 (swing gate), and BG 3000-B3 (barrier gate). ADDITIONAL COMPLEX INPUTS: Radio Cycle Interrupt Bar Photo-Sensors Fire Exit Loop MagLock Manual Inputs Inside Interrupt Loop Gate Gate Shadow Loop Operator Operator (swing gates
ページ8に含まれる内容の要旨
2. BI-PARTING LATCH GATE DETAILS The Bi-Parting Latch Gate is typically used in low traffic residential sites due to ease of use and added security of magnetic locking. The Bi-Parting Latch configuration can consist of any combination of models SL 1000-B3 (slide gate), SW 2000-B3 (swing gate), and BG 3000-B3 (barrier gate). ADDITIONAL INPUTS: Radio COMPLEX Cycle Interrupt Bar Photo Sensors Fire Exit Loop MagLock Manual Inputs Inside Interrupt Loop Gate Gate Shadow Loop Operator Operator Maste
ページ9に含まれる内容の要旨
3. TRAP GATE DETAILS The Trap gate is typically used in secured sites for screening incoming and/or outgoing traffic. In the Trap configuration, only one gate opens at a time, “trapping” the vehicle between gates. Due to ease of use, Slide Gates are the most popular for the Trap configuration. The Trap configuration can consist of any LiftMaster model for the Master, and a model SL 1000-B3 (slide gate), or BG 3000-B3 (barrier gate) for the Slave. NOTE: The SW 2000-B3 (swing gate) may not
ページ10に含まれる内容の要旨
There are 2 different ways to close the gate (entering or exiting): 1. Reclose Timer: When the Reclose Timer expires, gate closes automatically (Master or Slave). 2. Interrupt Loop: clearing the Inside Interrupt Loops cause the gates to close (Master or Slave). NOTE: To ensure gate closure, set Reclose Timer = ON in both Master and Slave units. INPUT CONNECTIONS: Refer to Part 2 Master/Slave Layout and Wiring, for more details • Master and Slave units require their own separate inputs. • If
ページ11に含まれる内容の要旨
4. TANDEM GATE DETAILS The Tandem gate is typically used in high traffic situations where some control of incoming and/or outgoing traffic is required. The outside gate (slave) is usually a less expensive fast moving barrier gate (or light slide gate) which protects the more expensive and less mobile Slide or Swing inside gate (master). The outside gate does this by stopping the vehicle until the inside gate is completely open. The Tandem configuration can consist of any LiftMaster model for
ページ12に含まれる内容の要旨
HOW IT WORKS: • When a vehicle is entering or exiting, the inside Master gate opens first. When the Master is completely open, the outside Slave gate opens, allowing the vehicle to enter or exit. • The Master unit Reclose Timer (if enabled) does not start counting down until the Slave gate is fully closed. Since ATG is not allowed in the Master unit, if the Reclose Timer is not enabled, the Master gate will remain open. • During high traffic hours, the slower-moving Master gate can be latched
ページ13に含まれる内容の要旨
PART 2 MASTER/SLAVE LAYOUTS AND WIRING A. PHOTO-SENSOR INSTALLATION FOR BIPARTING GATE CONFIGURATION BIPARTING SLIDE GATES Figure 6. Biparting Slide Gate Photo-Sensor Layout. WARNING Buy only UL-approved photo-sensors made for use with vehicular gate operators or system. Otherwise, safe gate operation may be compromised. IMPORTANT NOTE: The installation shown in Figure 6 above is a suggested layout using emitters and receivers. Any UL-approved photo-sensors are acceptable, but they must cov
ページ14に含まれる内容の要旨
BIPARTING SWING GATES Figure 7. Biparting Swing Gates Photo-Sensor Layout. WARNING Buy only UL-approved photo-sensors made for use with vehicular gate operators or system. Otherwise, safe gate operation may be compromised. IMPORTANT NOTE: The installation shown in Figure 7 above is a suggested layout using emitters and receivers. Any UL-approved photo-sensors are acceptable, but they must cover the entire area of gate travel to be effective. Install photo-sensors in three Coverage Areas as s
ページ15に含まれる内容の要旨
BIPARTING BARRIER GATES Figure 8. Biparting Barrier Gates Photo-Sensor Layout. WARNING Buy only UL-approved photo-sensors made for use with vehicular gate operators or system. Otherwise, safe gate operation may be compromised. IMPORTANT NOTE: The installation shown in Figure 8 above is a suggested layout using emitters and receivers. Any UL-approved photo-sensors are acceptable, but they must cover the entire area of gate travel to be effective. Install photo-sensors in three Coverage Areas
ページ16に含まれる内容の要旨
C. CONNECTING INPUT WIRING Figure 9. Control Board Wiring. IMPORTANT Before proceeding, see NOTES on the next page. Rev E Doc 01-20201 13 of 33
ページ17に含まれる内容の要旨
NOTES 1. Disconnecting the STOP terminal from the COMMON terminal stops the gate and prevents all commands from having any effect. Manual Open does not activate the Reclose Timer. 2. If gate(s) are used for bi-directional traffic, the Exit Loop should be a directional loop detector. 3. Inside and Outside Interrupt Loops: ♦ For maximum safety, Inside and Outside Interrupt loops require separate loop detectors. ♦ Bipart or Bipart Latch: If only one loop detector is used, the Outside loop must al
ページ18に含まれる内容の要旨
D. MASTER/SLAVE INTERCONNECTION • A conduit between the Master and Slave units should be provided for the Master/Slave interconnection cable. • Two shielded twisted pair wire 16 AWG to 24 AWG will be connected between the two units at TB1 on the controller Board NOTES: 1. Do not run the Master/Slave cable and AC power wires in the same conduit. 2. Master/Slave interconnection cabel should not exceed 3000 feet in length. E. MASTER/SLAVE WIRING 1. Select the desire gate layout in Section G. 2. B
ページ19に含まれる内容の要旨
F. SWITCH S1 MASTER SLAVE CONFIGURATIONS AND GATE CONTROLS SETTINGS: MASTER/SLAVE CONFIGURATIONS: Figure 11. Switch S1 Settings for Master/Slave Systems. Rev E Doc 01-20201 16 of 33
ページ20に含まれる内容の要旨
G. SYSTEM LAYOUTS AND CONTROL WIRING Additional Master Wiring (if needed): Can us Can us Can use Rad e Rad e Radiiio o o or or or Cy Cy Cyc c cllle i e i e ifff E E Ex x xiiittt Loo Loo Loop p p iiis s s not not not us us used. ed. ed. Fire Manual Inputs Interrupt Bar Directional Exit Loop Photo-Sensors Swing gate open MagLock direction and its Warning Relay Inside Interrupt Loop maximum arc. Tel. Line Shadow Loop Gate Gate (swing gates only) Operator Operator Master Slave Master/Slave Cable