ページ1に含まれる内容の要旨
S
e
e
h
t
P
i
a
w
g
The Chamberlain Group, Inc.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
www.liftmaster.com
®
GARAGE DOOR OPENER
Model 3800PLD
For Residential and Light Duty Commercial Use
Install On Sectional Doors With
Torsion Assemblies Only
Owner’s Manual
■ Please read this manual and the enclosed safety materials carefully!
■ Fasten the manual near the garage door after installation.
®
■ The door WILL NOT CLOSE unless The Protector System and cable tension monitor are
connected an
ページ2に含まれる内容の要旨
TABLE OF CONTENTS Introduction 2-5Operation 21-27 Safety symbol review and signal word review . . . . . . . .2 Operation safety instructions . . . . . . . . . . . . . . . . . . . . .21 Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Using your garage door opener . . . . . . . . . . . . . . . . . .21 Preparing your garage door . . . . . . . . . . . . . . . . . . . . . .4 Using the wall-mounted door control . . . . . . . . . . . . . .22 Tools . . . . . . . . .
ページ3に含まれる内容の要旨
Planning Survey your garage area to see if any of the conditions � The torsion bar must extend at least 1" to 5" below apply to your installation. Additional materials may (2.5 cm to 12 cm) past the bearing plate. be required. You may find it helpful to refer back to this � An electric outlet is required within 6' (1.8 m) of the page as you proceed with the installation of your opener. installation area. If outlet does not exist, contact a Depending on your requirements, there are several qualif
ページ4に含まれる内容の要旨
1 Preparing your Garage Door Before you begin: To prevent possible SERIOUS INJURY or DEATH: � Disable locks. • ALWAYS call a trained door systems technician if garage � Remove any ropes connected to garage door. door binds, sticks or is out of balance. An unbalanced garage � Complete the following test to make sure your garage door may not reverse when required. door is balanced and is not sticking or binding: • NEVER try to loosen, move or adjust garage door, door 1. Lift the door about hal
ページ5に含まれる内容の要旨
LOCK LIGHT Carton Inventory purchased. If anything is missing, carefully check the Your garage door opener is packaged in one carton which packing material. contains the motor unit and the parts illustrated below. Note that accessories will depend on the model Remote Control Visor Clip ® SECURITY✚ 3-Button Remote Control (1) Model 373P (1) Remote Light (Opener Light) with Hardware Bag Smart Control Panel™ 2-Conductor Bell Wire White & White/Red Power Door Lock 2-Conductor White & White/Blac
ページ6に含まれる内容の要旨
ASSEMBLY STEP 1 Attach the Collar to the Motor Unit To prevent possible SERIOUS INJURY or DEATH, the collar To avoid installation difficulties, do not run the garage MUST be properly tightened. The door may not reverse door opener until instructed to do so. correctly or limits may be lost due to collar slip. � Loosen the collar screws. � Attach collar to either the left or the right side of the motor unit. Ensure that the collar is seated all the way on motor shaft until stop is reached (Figure
ページ7に含まれる内容の要旨
WARNING WARNING INSTALLATION IMPORTANT INSTALLATION INSTRUCTIONS WARNING WARNING To reduce the risk of SEVERE INJURY or DEATH: 1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND 7. NEVER wear watches, rings or loose clothing while installing INSTRUCTIONS. or servicing opener. They could be caught in garage door or opener mechanisms. 2. Install garage door opener ONLY on properly balanced and lubricated garage door. An improperly balanced door may 8. Install wall-mounted garage door control: not re
ページ8に含まれる内容の要旨
DRILL 5/16" DRILL 3/4" DRILL 5/16" TOP TOP DRILL 5/16" DRILL 3/4" DRILL 5/16" NOT E IC INSTALLATION STEP 2 Attach the Emergency Release Rope To prevent possible SERIOUS INJURY or DEATH from a falling and Handle garage door: � Thread one end of the rope through the hole in the top • If possible, use emergency release handle to disengage door of the red handle so “NOTICE” reads right side up as ONLY when garage door is CLOSED. Weak or broken springs shown. Secure with an overhand knot at least 1"
ページ9に含まれる内容の要旨
Figure 1 INSTALLATION STEP 4 Attach the Cable Tension Monitor Opener (Required) Torsion Bar This opener comes standard with the cable tension monitor. It is supplied as a device to monitor the Drum cables for ANY slack that may occur and will reverse the door when excessive slack is detected, eliminating Cable service calls. The cable tension monitor MUST be connected and 2"-6" (5 cm- Cable properly installed before the garage door opener will 15 cm) Tension move in the down direction. Monito
ページ10に含まれる内容の要旨
LOCK LOCK LOCK LOCK LIGHT LIGHT INSTALLATION STEP 5 Install the Door Control To prevent possible SERIOUS INJURY or DEATH from electrocution: Locate door control within sight of door, at a minimum • Be sure power is not connected BEFORE installing door control. height of 5' (1.5 m) where small children cannot reach, • Connect ONLY to 24 VOLT low voltage wires. away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors To prevent possible S
ページ11に含まれる内容の要旨
WARNING WARNING IMPORTANT SAFETY INSTRUCTIONS WARNING WARNING To reduce the risk of SEVERE INJURY or DEATH: 1. This portable luminaire has a polarized plug (one blade is 5. NEVER use with an extension cord unless plug can be fully wider than the other) as a feature to reduce the risk of inserted. electric shock. 6. Do not alter the plug. 2. This plug will fit in a polarized outlet ONLY one way. 7. Light is intended for ceiling mount and indoor applications 3. If the plug does not fit fully in t
ページ12に含まれる内容の要旨
PERMANENT WIRING CONNECTION Flexible conduit PERMANENT WIRING CONNECTION INSTALLATION STEP 7 Electrical Requirements To prevent possible SERIOUS INJURY or DEATH from To avoid installation difficulties, do not run the opener electrocution or fire: at this time. • Be sure power is not connected to the opener, and disconnect power to circuit BEFORE removing cover to To reduce the risk of electric shock, your garage door establish permanent wiring connection. opener has a grounding type plug with a
ページ13に含まれる内容の要旨
INSTALLATION STEP 8 Mount the Standby Power Unit (SPU) (not provided) 475LM Standby Power System If the optional 475LM Standby Power Unit is part of this installation it should be installed at this time. � The SPU can be mounted to either the ceiling or a wall within 3' (.9 m) of the motor unit. � Position the SPU as desired to a structural support (ceiling joist or wall stud). � Attach the SPU to the support using the mounting holes on either side of the SPU. � Secure the SPU using the 1-1/2"
ページ14に含まれる内容の要旨
INSTALLATION STEP 9 ® Install The Protector System Be sure power is not connected to the garage door opener BEFORE installing the safety reversing sensor. The safety reversing sensor must be connected and aligned correctly before the garage door opener will To prevent SERIOUS INJURY or DEATH from a closing garage door: move in the down direction. This is a required safety device and cannot be disabled. • Correctly connect and align the safety reversing sensor. This required safety device MUST NO
ページ15に含まれる内容の要旨
INSTALLING THE BRACKETS DOOR TRACK MOUNT (RIGHT SIDE) Figure 1 Be sure power to the opener is disconnected. Install and align the brackets so the safety reversing sensors will Door face each other across the garage door, with the beam no Track higher than 6" (15 cm) above the floor. They may be Lip installed in one of three ways,as follows. Indicator Light Garage door track installation (preferred) (Figure 1): � Slip the curved arms over the rounded edge of each Sensor door track, with the curv
ページ16に含まれる内容の要旨
MOUNTING AND WIRING THE SAFETY REVERSING Figure 5 Wing Nut SENSORS 1/4"-20 � Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten safety reversing sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed Carriage Bolt 1/4"-20x1/2" by a bracket extension (Figure 5). Lens � Finger tighten the wing nuts. • Run the wires from both safety reversing sensors to the TROUBLESHOOTING THE SAFETY REVERSING open
ページ17に含まれる内容の要旨
LOCK LIGHT ADJUSTMENT STEP 1 Program the Travel Limits Without a properly installed safety reversal system, persons Travel limits regulate the points at which the door will (particularly small children) could be SERIOUSLY INJURED or stop when moving up or down. Follow the steps below KILLED by a closing garage door. to set the limits. • NEVER learn forces or limits when door is binding or sticking. Repair door first. Figure 1 Indicator • Incorrect adjustment of garage door travel limits will Li
ページ18に含まれる内容の要旨
LOCK LIGHT ADJUSTMENT STEP 2 Setting the Force Without a properly installed safety reversal system, persons The force setting button is located on the front panel. (particularly small children) could be SERIOUSLY INJURED or The force setting measures the amount of force KILLED by a closing garage door. required to open and close the door. • NEVER learn forces or limits when door is binding or sticking. Repair door first 1. Locate the purple button on the unit (Figure 1). • Too much force on gara
ページ19に含まれる内容の要旨
ADJUSTMENT STEP 3 Test the Safety Reversal System Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or TEST KILLED by a closing garage door. � With the door fully open, place a 1-1/2" (3.8 cm) board • Safety reversal system MUST be tested every month. (or a 2x4 laid flat) on the floor, centered under the • If one control (force or travel limits) is adjusted, the other garage door. control may also need adjustment. � Operate th
ページ20に含まれる内容の要旨
NOTICE ADJUSTMENT STEP 5 Test Cable Tension Monitor To prevent possible SERIOUS INJURY or DEATH from a falling garage door: If your cable tension monitor has been activated the • If possible, use emergency release handle to disengage door Indicator Light will blink 9 times. See (Figure 1) page 18. ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. ADJUSTMENT STEP 6 • NEVER use emergency release handle unles