V4055F,G Fluid Power Actuator
with Manual Control
PRODUCT DATA
FEATURES
• Fast opening time of 13 seconds at 120 V, 60 Hz.
• Maximum closing time, is 1 second, which meets approval
body requirements.
• Unit available with FM approved proof of closure switch.
• Red “OPEN” indicator attached to the actuator piston will
show if the valve is even slightly open; yellow “SHUT”
indicator on the valve stem will show only when the gas
valve is fully closed.
• Ambient temperature rating of -40°F to +1
ページ2に含まれる内容の要旨
V4055F,G FLUID POWER ACTUATOR WITH MANUAL CONTROL SPECIFICATIONS Models: Closing Time: 1 sec maximum when de-energized. V4055G Fluid Power Actuator with Manual Control-for use Ambient Operating Temperature Rating: with the V5055 valve. Provides ON-OFF control. Rated for 5 -40°F to +150°F (-40°C to +66°C) for 60 Hz models; -10°F to PSI. +158°F (-23°C to +70°C) for 50 Hz and 50/60 Hz models. V4055F-Same as V4055G except: for use with V5055C only. Mounting Means: Meets UL and FM proof of closur
ページ3に含まれる内容の要旨
V4055F,G FLUID POWER ACTUATOR WITH MANUAL CONTROL Fig. 1. Approximate mounting dimensions of V4055 actuators and V5055 valves, in inches. (mm). 2 6-3/4 (172) 3-23/32 (95) 5 (127) 27/32 (22) KNOCKOUT 1 ALLOW 4 INCHES (102 MM) CLEARANCE FOR ACTUATOR FOR1/2 INCH REMOVAL. CONDUIT (4) 2 ADD 1/8 INCH (3 MM) TO DIMENSION FOR MODELS WITH NEMA 4 ENCLOSURE. 1-9/32 (33) 3 ADD 1/4 INCH (6 MM) TO DIMENSION FOR A MODELS WITH NEMA 4 ENCLOSURE. 1 A 3 3/4 (19) BOLT C HOLES [8] ON 3-3/4 (95) RADIUS B E 9-3/16
ページ4に含まれる内容の要旨
V4055F,G FLUID POWER ACTUATOR WITH MANUAL CONTROL CAUTION Electrical Shock and Equipment Damage Hazard. Can cause serious injury or death. 1. Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. 2. All wiring must comply with all applicable electrical codes, ordinances and regulations. All wiring must be NEC Class 1. 3. Voltage and frequency of the power supply connected to this control must agree with those marked on the device. 4. Max
ページ5に含まれる内容の要旨
V4055F,G FLUID POWER ACTUATOR WITH MANUAL CONTROL Mount Actuator On Valve L1 HOT Check the final position of the valve body to be sure that the 1 actuator will be in the proper position when mounted on the 1 2 L2 valve. If two smaller size valves are mounted very close together, as in an Industrial Risk Insurers (formerly F.I.A.) type valve train, it may be necessary to mount the actuator “off center” to provide adequate clearance. PROOF-OF-CLOSURE SWITCH Slip the bottom collar of the actua
ページ6に含まれる内容の要旨
V4055F,G FLUID POWER ACTUATOR WITH MANUAL CONTROL 1. Turn off the gas supply at the manual shutoff valve the bonnet assembly is seated. Tighten the located upstream from the valve(s) being serviced. remaining bolts. Torque the bolts as 2. Shut off all electrical power to the valve actuator(s). follows: 3. Mark and disconnect the wires from the actuator termi- nals. Remove conduit and disengage the damper linkage Valve Size Torque assembly (if applicable. 3/4 in. (19 mm) to 1-1/2 in. (38 mm) 55
ページ7に含まれる内容の要旨
V4055F,G FLUID POWER ACTUATOR WITH MANUAL CONTROL 7 65-0029-02
ページ8に含まれる内容の要旨
V4055F,G FLUID POWER ACTUATOR WITH MANUAL CONTROL Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North ® U.S. Registered Trademark © 2012 Honeywell International Inc. Golden Valley, MN 55422 65-0029-02 JPG Rev. 11-12 Printed in United States customer.honeywell.com