ページ1に含まれる内容の要旨
™
Model 1610 Easy Install Media Air Cleaner
Installation Instructions
WARNING CAUTION
1. High voltage may cause serious 1. T o prevent component failure, do not install the air cleaner on the warm
injury from electrical shock. air supply or in an area where the temperature may exceed 140°F. This
Disconnect power to the may include areas above heat exchangers in downflow furnaces or above
furnace/air handler before exhaust flues in lowboy furnace cold air returns.
starting installation.
ページ2に含まれる内容の要旨
lOCATING THE AIR ClEANER 1. The air cleaner can be mounted on the right or left side of the HVAC equipment (see Figure 2). 2. The door can be facing the front or rear of the HVAC equipment cabinet (see Figure 2). 3. The door and blanking plate are reversible to allow filter access from the front or rear of the HVAC equipment cabinet (see Figure 2). 4. Leave sufficient space (29”) for the removal of the filtering media (see Figure 3). FIGURE 2 FIGURE 3 The door and blanking panel are rev
ページ3に含まれる内容の要旨
2. The “L” bracket can removed to form a 10”x 24” drop opening. See Figure 6. 3. If the cold air drop is less than 24 inches deep an angle bracket can be field fabricated and installed to reduce the drop width. See Figure 7. 4. The cold air return can be moved into position over the top of the air cleaner (Figure 8) or transition pieces field fabricated (Figure 9). 5. Four tabs are located on the outlet side of the air cleaner. These tabs can be bent into the cold air return opening on the
ページ4に含まれる内容の要旨
INSTAll THE AIR ClEANER CABINET WARNING 120 Volts may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation. leave power disconnected until installation is completed. 1. Disconnect power to the furnace or air handler at the FIGURE 11 electrical service panel. 2. Remove filtering media from the air cleaner cabinet. 3. If replacing an existing filter, remove the filter and thoroughly clean the blower compartment. 4. Determine