ページ1に含まれる内容の要旨
Model APS-45
Installation Manual
Keyless Entry System
With Two Auxiliary Outputs
Installation Instructions
This Unit Is Intended For Installation In Vehicles With
12 Volt Negative Ground Electrical Systems Only.
Kit Contents:
w APS-45 Control Module
w (2) - Two Button Transmitters
w 4 Channel Code Learning Receiver
w On Board Antenna
w (1) - Multi Pin Input/Output Harness
w (1) - Three Pin Door Lock Harness
w (1) - Two Pin LED Indicator
w (1) - Two Pin Valet / Override Switch
w (1) - 10 Amp In-
ページ2に含まれる内容の要旨
The APS-45 Keyless Entry System is designed to provide a convenient electronic means to gain access to the vehicle by providing RF remote control over the vehicle's power door lock system. The unit also includes outputs to control the vehicle's dome lights, as well as exterior parking lights. Although not an alarm system, the APS-45 also incudes a starter interrupt circuit output. It also includes two additional auxiliary outputs designed to allow for control over optional devices such as a p
ページ3に含まれる内容の要旨
light systems in these vehicles, you must use a separate SPDT relays to connect to each side in order to keep them isolated. Attach the WHITE wire of the system to this point. BROWN Wire: Negative (-) Door Sense Input Wire If the vehicle's interior lights are controlled by grounding door pinswitches (typical of most GM, Chrysler, and import vehicles), the Brown negative door sense wire should connect to one of the vehicle's factory door pin switches. In many cases the factory door pinswitches a
ページ4に含まれる内容の要旨
transmitter buttons simultaneously will access Channel 3 and will remain active for as long as the transmitter button(s) is held. This is a low current output and must be connected to a relay to supply power to the device you intend to control. Connect Green/Black Trace wire to terminal #86 of a VF45F11 P&B relay or equivalent. Connect terminal #85 of the relay to a fused + 12 volt source. Connect the common, normally open, and normally closed contacts of the relay to perform the selected fun
ページ5に含まれる内容の要旨
wire that provides a low current positive signal from the factory door lock switch to the factory door lock control relay. 3 Wire Positive Switched 2 Step Door Locks The green wire provides a positive pulse during locking, or the pulsed + 12 volt lock output. Connect the green wire to the wire that provides a low current positive signal from the factory door lock switch to the factory door lock control relay. The red wire provides a positive pulse during unlocking, or the drivers door pulsed pos
ページ6に含まれる内容の要旨
If you desire to have the transmitters operate differently from this factory configuration, please refer to the separate Trans- mitter Programming Guide that came with the APS-45 system. PROGRAMMING FEATURES: There are seven (7) Programmable Features on the APS-45 system. Study the list below, keeping in mind the features and their defaults, (how it comes programmed from the factory), and decide how best to program the APS-45 for your particular installation. Programmable Features: Features 1 C
ページ7に含まれる内容の要旨
FEA TURE A CTION TO PERFORM RESPONSE FROM SYSTEM LED FLA SH PA TTERN To Turn the Ignition Switch ON LED Turns OFF Enter Toggle the Valet/Program/Manual Override Switch The ON then OFF 3 Times 1 Siren/Horn Chirp & 1 LED Flash Programming Within 3 seconds, M ode turn the Ignition Switch OFF, then ON 1 Short Chirp, and 1 Long Chirp You have now engaged the Programming M ode, and are set to adjust the First feature This mode will time out automatically in 15 seconds, or can be cancelled by turning
ページ8に含まれる内容の要旨
(-) (+) (+) (-) APS-45 OPTIONAL OPTIONAL © 1999 Audiovox Corp. 128-5621