PRINTER’S INSTRUCTIONS:
INSTR,INSTL,AK-3 - LINEAR P/N: 221025 B - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH
AK-3
Digital Keyless
Entry System
1
4
5
6
7
8
9
0
Installation and Programming Instructions
(760) 438-7000
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
221025 B IMAGE 1
ページ2に含まれる内容の要旨
CONTENTS FEATURES COMPONENT LOCATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ✓ KEYPAD PROGRAMMABLE WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 No programmer required INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ✓ 480 ENTRY CODE CAPACITY Opening the Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ページ3に含まれる内容の要旨
2 3 COMPONENT LOCATIONS RED/GREEN YELLOW POWER/ACCESS "LOCKOUT" MASTER CODE INDICATOR INDICATOR RESET JUMBER (P5) TERMINAL BLOCK #1 (TB1) 1 4 5 6 7 8 9 0 BEEPER KEYPAD LEVEL MOUNTING JUMPER (P4) PLATE Figure 1. Component Locations WIRING DIAGRAM TYPICAL DOOR INSTALLATION WIRING AK-3 TERMINALS TERMINAL WIRES BLOCK 1 GRAY 12-24 VOLT 1 - AC OR DC SENSE - 8 POWER N.C. DOOR AC OR DC BLACK SUPPLY SWITCH 2 - AC OR DC GROUND - 7 POWER VIOLET 3 - N.O. REQUEST-TO-EXIT - 6 MAIN RELAY BLACK 5 AMPS @ 4 - COM
ページ4に含まれる内容の要旨
INSTALLATION Before installing the keypad, the unit must be partially disassembled Final Keypad Installation to access the mounting plate. After wiring the keypad (see next page), complete the installation by securing the keypad to the mounting plate. Opening the Keypad ❑ If a lower beeper sound level is required, before installing The keypad assembly is secured with two screws that are hidden the keypad, remove Jumper at P4 (place the jumper block behind the keypad’s nameplate. Refer to F
ページ5に含まれる内容の要旨
3 Keypad Wiring 2 WIRES See Figure 6 for an example of a basic door installation. The DOOR FOR DOOR SENSE keypad is mounted adjacent to the door. An electric door strike SENSE SWITCH is mounted in the door jamb to release the door lock. A magnetic SWITCH switch is mounted on the top of the door jamb for detecting when the door is open. Use the following steps to wire the keypad. Refer to the wiring 2 WIRES diagram shown in Figure 7 to assist in the wiring. AK-3 FOR DOOR ☞ NOTE: Up to 500 fee
ページ6に含まれる内容の要旨
FACTORY DEFAULTS Adding a New Entry Code MASTER PROGRAMMING CODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123456 Press: 0 1 # Code # Code # Relay # ENTRY CODE LENGTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DIGITS Code = The new entry code: 1-999999, depending on code length REQUEST-TO-EXIT OUTPUT RELAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MAIN RELAY Relay = Relay output entry code
ページ7に含まれる内容の要旨
Program all normal entry codes to use the Main Relay (Relay #1), Select Keypad Active Output Default: No Output and only Relay #1 as the output relay. Program the code(s) that Sets which output activates when any keys are pressed. This output is timed. If you want to use to hold the output for an indefi nite period to the toggle mode is selected for the output, the timer value defaults to 2 seconds. Auxiliary Relay (Relay #2). See the following example that sets entry codes 1234 for normal a
ページ8に含まれる内容の要旨
AK-3 OPERATION Beep Sounds During Auxiliary Relay Default: No Selects whether or not the keypad beeps during Auxiliary Relay activation. Keypad users request access by entering their code. ❑ Users of the AK-3 have up to 40 seconds to key in their Press: 4 2 # Sound # entry code. Sound = 1 for Yes, = 0 for No ❑ Up to eight seconds are allowed between each keystroke. ❑ All digits of the entry code must be entered. Example: If the code is 0042, the user must enter Beep Sounds During Output #3 De