ページ1に含まれる内容の要旨
PDxx01 RS-232C Control
Specification : Rev.1.0
PDxx01
RS-232C Control Specification
Category : Plasma Display
Document Version : 1.0
Author(s) : Marantz America, Inc.
Date : 2006/12/07
Number of Page : 49
Marantz America, Inc. 2006
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of copyright.
All specifications might be subject to change without notice.
ページ2に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 2 / 49 Document Version [1.0] Table of Contents 1. Application........................................................................................................................................... 4 2. Connections......................................................................................................................................... 4 2-1. Connector on the plasma monitor side: EXTERNAL CONTRO
ページ3に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 3 / 49 Document Version [1.0] 5-38. HD Select..................................................................................................................................................... 26 5-39. LANGUAGE Select...................................................................................................................................... 26 5-40. COLOR SYSTEM Select...................................
ページ4に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 4 / 49 Document Version [1.0] 1. Application These specifications are applicable to plasma monitors and communications control from external equipment. "Please also support the command of VP series and refer to the manual of the conventional model about specification." 2. Connections Connections should be made as described below. External equipment plasma monitor e.g., Personal computer
ページ5に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 5 / 49 Document Version [1.0] 3. Communication Format 8bit 8bit 8bit 8bit 8bit 8bit 8bit 8bit Command 1 Unit ID 1 Unit ID 2 Command 2 Data length Data Check sum 3-1. Command1 Command 1, along with command 2, is a number used to distinguish each command. Bit1, Bit0: 11B or 10B :Usually, a form In the case of ACK, when the lower order 4 bits is FH (as in 3FH and 7FH), this indicates that the comma
ページ6に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 6 / 49 Document Version [1.0] 4. Command Reference List CMD1 CMD2 LEN 01 Power ON 9FH 4EH 00H 02 Power OFF 9FH 4FH 00H 03 Input Switch Change DFH 47H 01H 04 VOLUME Gain Data DFH 7FH 03H 05 AUDIO Mute ON 9FH 3EH 00H 06 AUDIO Mute OFF 9FH 3FH 00H 07 CONTRAST Gain Data DFH 7FH 03H 08 BRIGHT Gain Data DFH 7FH 03H 09 SHARPNESS Gain Data DFH 7FH 03H 10 Color Gain Data DFH 7FH 03H 1
ページ7に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 7 / 49 Document Version [1.0] 60 PICTURE FREEZE DFH 7CH 01H 61 PAUSE COMMAND DFH 7DH 01H 62 OSM CONTRAST DFH 37H 01H 63 CLOSED CAPTION DFH 3CH 01H 64 CAPTION CONTRAST DFH 3DH 01H 65 PICTURE MEMORY Select DFH 38H 01H 66 PICTURE MEMORY Set DFH 25H 02H 67 PICTURE MEMORY NOTE WRITE DFH 2DH 0CH 68 SET UP LEVEL DFH 35H 01H 69 BACK GROUND DFH 36H 01H 70 PDP SAVER AUTO select DFH 2CH 01H 71 Audio HDMI Request 1FH
ページ8に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 8 / 49 Document Version [1.0] 5. Command 5-1. Power ON Function The external control equipment switches on the power of the plasma monitor. Transmission Data 9FH 80H 60H 4EH 00H CKS ACK The plasma monitor returns the following ACK when the power is switched on. 3FH 60H 80H 4EH 00H CKS NOTE: Do not set the Power ON or Power OFF command continuously. 5-2. Power OFF Function The
ページ9に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 9 / 49 Document Version [1.0] 5-4. VOLUME Gain Data Function The external control equipment changes the VOLUME gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER SOUND Gain Flag 05H DATA01: VOLUME Gain Flag 01H DATA02: VOLUME Gain 00H: Step0 : 0AH: Step10 (Default) : 2AH: Step42 ACK 7FH 60H 80H 7FH 02
ページ10に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 10 / 49 Document Version [1.0] 5-7. CONTRAST Gain Data Function The external control equipment changes the CONTRAST gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: CONTRAST Gain Flag 07H DATA02: CONTRAST Gain CCH: -52 : FFH: -01 00H: 0 01H: +01 : 14H: +20 ACK 7
ページ11に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 11 / 49 Document Version [1.0] 5-9. SHARPNESS Gain Data Function The external control equipment changes the SHARPNESS gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: SHARPNESS Gain Flag 06H DATA02: SHARPNESS Gain F0H: -16 : FFH: -01 00H: 0 01H: +01 : 10H: +16 Only wh
ページ12に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 12 / 49 Document Version [1.0] 5-11. TINT Gain Data Function The external control equipment changes the TINT gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: TINT Gain Flag 05H DATA02: TINT Gain E0H: -32 : * TINT Gain is from -22 (EAH) to FFH: -01 +22 (16H) only during video. 0
ページ13に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 13 / 49 Document Version [1.0] 5-13. COLOR TEMP SELECT Function The external control equipment changes the COLOR TEMP of the plasma monitor. Transmission Data DFH 80H 60H 00H 01H DATA00 CKS DATA00: 00H: low 01H: middle 02H: high 03H: middle low ACK 7FH 60H 80H 00H 01H DATA00 CKS DATA00: 00H: low 01H: middle 02H: high 03H: middle low 5-14. RED Gain Data Function The exte
ページ14に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 14 / 49 Document Version [1.0] 5-15. GREEN Gain Data Function The external control equipment changes the GREEN Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: GREEN Gain Flag 02H DATA02: GREEN Gain1 (Bias) D8H: -40 : FFH: -01 00H: 0 01H: +01 : 1EH: +30 DATA03: GREEN Gain2(Drive) D8
ページ15に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 15 / 49 Document Version [1.0] 5-17. NR MODE Set Function The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor. Transmission Data DFH 80H 60H C0H 01H DATA00 CKS DATA00: 01H: NR OFF 02H: NR-1 03H: NR-2 04H: NR-3 ACK 7FH 60H 80H C0H 01H DATA00 CKS DATA00: 01H: NR OFF 02H: NR-1 03H: NR-2 04H: NR-3 5-18. BASS Gain Data Function The e
ページ16に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 16 / 49 Document Version [1.0] 5-19. TREBLE Gain Data Function The external control equipment changes the TREBLE gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA0 CKS DATA00: USER PICTURE Gain Flag 05H DATA01: TREBLE Gain Flag 04H DATA02: TREBLE Gain F3H: -13 : FFH: -01 00H: 0 01H: +01 : 0DH: +13 ACK 7FH 60H 80H 7FH 02
ページ17に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 17 / 49 Document Version [1.0] 5-21. SCREEN MODE Select Function The external control equipment switches the screen mode of the plasma monitor. Transmission Data DFH 80H 60H 51H 01H DATA00 CKS DATA00 02H: STADIUM 03H: ZOOM 04H: NORMAL 05H: ANAMORHIC (FULL) 06H: REAL 08H: UNDERSCAN 09H: 14:9 0AH: 2.35:1 ACK 7FH 60H 80H 51H 01H DATA00 CKS DATA00 02H: STADIUM 03H: ZOOM 04H
ページ18に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 18 / 49 Document Version [1.0] 5-23. H. POSITION Gain Data Function The external control equipment changes the H. POSITION gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag 03H DATA01: H.POSITION Gain Flag 02H DATA02: H.POSITION Gain 80H: -128 : FFH: -01 00H: 0 01H: +01 : 7FH: +127 ACK 7
ページ19に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 19 / 49 Document Version [1.0] 5-26. AUTO PICTURE Select Function The external control equipment switches on or off the AUTO PICTURE of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag 03H DATA01: AUTO PICTURE Select Flag 09H DATA02 00H: ON 01H: OFF ACK 7FH 60H 80H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00
ページ20に含まれる内容の要旨
PDxx01 RS-232C Control Specification Page: 20 / 49 Document Version [1.0] 5-28. CLOCK (PICTURE ADJUST) Gain Data Function The external control equipment changes the CLOCK gain data (ratio of frequency division) of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag 03H DATA01: CLOCK Gain Flag 04H DATA02: CLOCK Gain C0H: -64 : FFH: -01 00H: 0 01H: +01