Installation/Operation
KBD300A
Universal Keyboard
C527M-L (3/04)
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120
ページ2に含まれる内容の要旨
[ 2 ] Pelco Manual C527M-L (3/04)
ページ3に含まれる内容の要旨
CONTENTS Section Page IMPORTANT SAFETY INSTRUCTIONS ........................................................................................................... 5 REGULATORY NOTICES .................................................................................................................................. 6 DESCRIPTION ................................................................................................................................................. 7 INSTALLATION – CM6700 MODE
ページ4に含まれる内容の要旨
List of Illustrations Figure Page 1 Wiring Diagram for Local/Remote Keyboards ................................................................................... 10 2 Keyboard Cabling Diagram ................................................................................................................. 10 3 Data Cables Plugged into COM 5 and 6 (CM6800-48X8 Shown) ...................................................... 12 4 Connecting Remote Keyboards (CM6800-48X8 Shown) ........................
ページ5に含まれる内容の要旨
IMPORTANT SAFETY INSTRUCTIONS Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Only use attachments/accessories specified by the man
ページ6に含まれる内容の要旨
REGULATORY NOTICES This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference re- ceived, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provid
ページ7に含まれる内容の要旨
DESCRIPTION The KBD300A Universal Keyboard has many operational features (refer to Table A) and can be used in nu- merous operational modes: CM6700 Mode: Program and operate the CM6700 Matrix Switcher/Controller Unit (SCU). Also control a ® Genex multiplexer from a CM6700. Multiple keyboards can be used in this mode. CM6800 Mode: Program and operate the CM6800 Matrix Switcher/Controller Unit (SCU). Also control a Genex multiplexer from a CM6800 SCU. Multiple keyboards can be used in this mode.
ページ8に含まれる内容の要旨
Table A. KBD300A Operational Features CM6700/ Direct CM6700 CM6800 Direct Function CM6800 P* ASCII** ASCII** D** Automatically recognize the mode Yes Yes No No No Select cameras (control only for Direct Mode) Yes Yes Yes No Yes Select monitors Yes No Yes Yes No Control lenses Yes Yes Yes Yes Yes Set and call presets/patterns Yes Yes Yes Yes Yes Create Zones Yes No Yes No Yes Control latching receiver auxiliaries Yes Yes Yes Yes Yes Control momentary receiver auxiliaries Yes Yes Yes Yes Yes Cont
ページ9に含まれる内容の要旨
INSTALLATION – CM6700 MODE There are two keyboard ports on the CM6700 SCU. The LOCAL KEYBOARD port is for connecting a single keyboard within a distance of 25 feet (7.6 meters). The REMOTE KEYBOARD(S) port is for connecting additional remote keyboards. Connecting a Keyboard to the Local Keyboard Port Use the data cable that is supplied with the keyboard. Plug one end of the cable into the RJ-45 connector on the rear of the keyboard and the other end into the LOCAL KEYBOARD port on the SCU (ref
ページ10に含まれる内容の要旨
KBD LOCAL KEYBOARD LOCAL KEYBO ARD 1 25-FOOT KEYBOARD DATA CABLE CM6700 USER-SUPPLIED CABLE ADDITIONAL 3 KEYBOARDS REPLACE REPLACE 6 6 COVER COVER KBD KBD 7 2 2 7 KBDKIT 8 8 SET SWITCHES 25-FOOT KEYBOARD 25-FOOT KEYBOARD DATA CABLE DATA CABLE REMOTE KEYBOARDS 01225 Figure 1. Wiring Diagram for Local/Remote Keyboards LOCAL RJ-45 WALL BLOCK TERMINALS 45 3 6 2 7 T+ T- R- R+ 1 8 4 4 TERMINAL TERMINAL USER-SUPPLIED CABLE 1 1 TX+ TX+ TX- 2 TX- 2 AC 3 AC 3 5 5 AC 4 AC 4 GND 5 GND 5 6 6 RX- 7 RX- 7 RX
ページ11に含まれる内容の要旨
INSTALLATION – CM6800 MODE You can connect up to eight KBD300A keyboards to any of the following ports: For the CM6800-48X8: COM 5 (one direct-powered keyboard or up to eight remotely connected keyboards) COM 6 (same as COM 5) COM 7 (up to eight remotely connected keyboards) COM 8 (same as COM 7) The total number of KBD300A Series keyboards connected to the CM680-48X8 cannot exceed 16. For the CM6800-32X6: COM 4 (up to eight remotely connected keyboards) COM 5 (one direct-powered keyboard or up
ページ12に含まれる内容の要旨
MAXIMUM NUMBER OF KEYBOARDS POWERED BY COM 5 & 6: 1 PER PORT NOTE: THE TOTAL NUMBER OF KBD300A SERIES KEYBOARDS CONNECTED TO THE CM6800 CANNOT EXCEED 16. KBDKIT(-X) REQUIRED WHEN WIRING MORE THAN 1 KEYBOARD TO A PORT. KBD300A KBD300A ALAR M 12 3 4 5 678 CO M 16 1 5 CO NTRO L PTZ 2 6 AT T R R T T R R B + - + - + - + - 31 32 3 7 OUT 3 4 8 1 2 3 4 CO M 1 7 8 120/230~ VIDE O O UTPUTS 50/60 HZ 25 WATTS CM6800 COM 5 & 6 KBD300A RJ-45 PIN-OUTS RJ-45 PIN-OUTS 1 Rx+ 1 Tx+ 2 Rx- 2 Tx- 3 KBD 12V
ページ13に含まれる内容の要旨
Connecting KBD300A Remote Keyboards For remote keyboard connections, use COM 5, 6, 7, or 8 for the CM6800-48X8 and COM 4 and 5 for the CM6800-32X6. Each port can support up to eight KBD300A keyboards. Do not exceed 16 total keyboards for the CM6800-48X8 and eight total keyboards for the CM6800-32X6. A KBDKIT or KBDKIT(-X) is required to connect remote keyboards. Each kit contains two RJ-45 wall blocks and a transformer. Use one wall block for each keyboard. Refer to Figure 4 (CM6800-48X8 shown).
ページ14に含まれる内容の要旨
MAXIMUM NUMBER OF KEYBOARDS: 8 PER PORT NOTE: THE TOTAL NUMBER OF KBD300A SERIES KEYBOARDS CONNECTED TO THE CM6800 CANNOT EXCEED 16. ALARM CM6800 COM 7 & 8 KBD300A 12 3 4 5 678 CO M RJ-45 PIN-OUTS RJ-45 PIN-OUTS 16 1 5 1 Rx+ 1 Tx+ CO NTR O L 2 Rx- 2 Tx- 2 6 PTZ 3 12V 3 NC AT T R R T T R R B + - + - + - + - 4 12V 4 NC 31 32 3 7 OUT 5 GROUND 5 GROUND F 6 NC 6 NC 3 4 8 1 2 3 4 7 Tx- 7 Rx- CO M 1 8 Tx+ 8 Rx+ 7 8 120/230~ VIDEO O UTPUTS 50/60 HZ 25 WATTS 4 5 3 6 2 7 1 8 4-CO
ページ15に含まれる内容の要旨
INSTALLATION – CM6700 ASCII MODE One ASCII keyboard can be installed, using either an RS-232 or RS-422 interface. If additional local and remote keyboards are used, you should install them according to the instructions in the Installation – CM6700 Mode and Installation – CM6800 Mode sections before doing an ASCII installation. For installation at a remote location that is served by an RS-232 communications facility (such as via dial- up phone lines), use an RS-232 connection at both the KBD keyb
ページ16に含まれる内容の要旨
Set the keyboard DIP switches for ASCII Mode according to the instructions in the Switch Settings section. Plug in the keyboard data cable.
Plug the +12 VDC power supply into a suitable outlet. Plug the KBDKIT or KBDKIT-X transformer into a suitable outlet. Apply power to the CM6700 SCU (if not already powered). To initialize the keyboard, wait five sec- onds after power-up, enter the number for the monitor you are viewing (1-4), and press MON. The LED display shows the number ent
ページ17に含まれる内容の要旨
RS-422 Interface (CM6700) Refer to Figure 6. Remove the cover from the CM6700 SCU and verify that the DIP switches for COM 2 are set for RS-422. Refer to the COM 2 Port section in the CM6700 Installation/Operation Manual for setting the switches. Reinstall the cover. Use an existing CM6700 keyboard to program the COM 2 communication port. (If there is no other keyboard, use the one you are installing. Set all DIP switches OFF and plug the keyboard into the Lo- cal Keyboard port on the back
ページ18に含まれる内容の要旨
NOTE: A SEPARATE PATH MUST BE PROVIDED 1 CM6700SCU FOR VIDEO TO THE MONITOR. LOCAL KBDKIT KEYBOARD RJ-45 WALL BLOCK 10 TERMINALS POWER UP 2 SCU 45 6 3 6 REPLACE 2 7 COVER 1 8 4 TERMINAL 1 KBD300A 2 3 3 MAXIMUM DISTANCE 5 4 OF 4,000 FEET. USE 4 5 SHIELDED TWISTED 25-FOOT 6 PAIRS SUCH AS BELDEN KEYBOARD 8 7 7 DATA CABLE 9843 OR EQUIVALENT. SET SWITCHES 8 SCU COM 2 TO WALL BLOCK 12 VAC PIN TERMINAL 12 (RX+) 1 (TX+) 11 (RX-) 2 (TX-) 9 8 (TX-) 7 (RX-) 7 (TX+) 8 (RX+)
ページ19に含まれる内容の要旨
INSTALLATION – CM6800 ASCII MODE RS-232 Interface (CM6800) An RS-232/RS-422 converter and power supply (Pelco part number PV130) are required. They are not included and must be ordered separately. Refer to Figures 7 (CM6800-48X8 shown) and 9. Use an existing CM6800 keyboard to program the COM 1, 2, 7, or 8 communication port for the CM6800-48X8 or COM 1 or 2 communication port for the CM6800-32X6. (If there is no other key- board, use the one you are installing. Set all DIP switches OFF and p
ページ20に含まれる内容の要旨
Apply power to the CM6800 (if not already powered). To initialize the keyboard, wait five seconds after power-up, enter the number for the monitor you are viewing, and press MON. The LED display shows the number entered. You can now use the keyboard to perform all normal keyboard functions, except you cannot program the CM6800. Go to the Programming and Operation section and program and test for proper operation. PELCO SWITCHER MODEL CM6800 MAIN MENU 1 CAMERA SET SERIAL PORT 05 2 LOGICAL C