ページ1に含まれる内容の要旨
1
ページ2に含まれる内容の要旨
1 Do not look directly at the lamps, without UV protective glasses. 2 Read instruction manual before operating the units. 3 Use recommended accessories (i.e. lamps, ballast) 4 Make sure unit is installed so that the UV light can not be seen directly through any returns or supplies. 5 Check damaged parts: Before further use of the unit, any damaged part should be carefully checked to ensure that the unit will operate properly. Any part that is damaged should b
ページ3に含まれる内容の要旨
WARRANTY LIMITATIONS This warranty will be voided if the covered equipment (only second wind replacement parts or units are warranted) is removed from the original installation site. This warranty does not cover damage or defect resulting from: 1 Accident, or neglect or unreasonable use or operation of the equipment, including operation of electrical equipment at voltages other than the range specified on the unit name plate. 2 Modification, change or alteration of the equipment, except
ページ4に含まれる内容の要旨
PAGE Safety Concerns 2 Warranty 2-3 Unpacking 4 Installation Locations 5 Installation 1000 Series 6 Lamp Replacement 7 Troubleshooting 8 Replacements Parts 8 1000 Series Cut Sheet 9 1000 Series Cut Sheet 10 Your new Second Wind Air Purifier is shipped complete in one container. 6 Carefully unpack the unit and all loose items from the shipping container. Figs. 2 illustrate the unit and all loose items packed with the unit. 1 4 1 Unit
ページ5に含まれる内容の要旨
The Second Wind Air Purifier has been tested effective in the destruction and reduction of bacteria, viruses and fungus under various conditions. The effectiveness of this device may vary depending upon room area and rate of circulation. The health aspects associated with this product were not investigated by U.L. WARNING!!! DO NOT LOOK AT THE ULTRA-VIOLET LIGHT DO NOT OPERATE UNTIL IT IS INSTALLED IN THE RETURN OR SUPPLY. TO DETERMINE AN INSTALLATION LOCATION SEE: FIG.3 5
ページ6に含まれる内容の要旨
• Installation should be done by a qualified HVAC contractor. • Read all safety instructions at the beginning of this manual. • Make sure unit is installed so that the UV light can not be seen directly through any returns or supplies. • Units should not be installed with in 12-18 inches of any non UV resistant materials. If ma- terials are in question call manufacturer of said products to see if they are made with UV inhibitors. Prolonged UV exposure will degrade non UV resistant materia
ページ7に含まれる内容の要旨
Second Wind Air Purifier lamps are designed to be on all the time. After approximately 9000-11000 hours of operation the lamps intensity will decrease. Installation of a replacement lamps is best handled by a HVAC Contractor. Both lamps must be replaced at the same time for the MODEL 1000KCS. 1 Turn unit off and make sure the power is off to the unit. Wait for lamp to cool. 2 Remove screws from around the unit, do not remove the screws from the hinge. (Fig.13) 3 Drop unit dow
ページ8に含まれる内容の要旨
1 Make sure that the unit is wired properly and 1002KCS is turned on. • For the 240 vac units 1002kcs the ballast 2 Check the on/off switch to make sure it is resistance should be tested like before. on. Disconnect power. For the 240 vac ballast 3 If the lamp is still not on, switch the unit (#SS2060446) the resistance should be 14- off, disconnect power and check the fuse. 25 ohms. If below 14 ohms replace the bal- 4 Make sure the lamp is not broken and that last. it is in
ページ9に含まれる内容の要旨
Since the first ultraviolet irradiation The Second Wind Purifier is the perfect choice for system was used successfully in 1909, small or large applications . Second Wind uses ultraviolet irradiation has had a 94 year ultraviolet germicidal light and singlet oxygen performance history. Second Wind process to disinfect mold, bacteria, infectious uses the ultraviolet wavelength at disease, and decrease volatile organic compounds 253.7nm, ultraviolet radiation lethal to in the air stream.
ページ10に含まれる内容の要旨
Second Wind Air Purification 1000KCS and Dimensions: 1002KCS units are mounted in the return to 1000KCS- 6”W x 3.25” H x 14”L x 2-9” Lamps accommodate most HVAC systems. The units 1002KCS - 6”W x 3.25”D x 23”L x 2-18” Lamps install anywhere in the system to disinfect molds, bacteria or reduce VOC Weight contamination. The housing is steel and 1000KCS - 6 lbs. comes in 2 sizes (9” and 18” lamps). All units 1