ページ1に含まれる内容の要旨
OWNER'S MANUAL
DC-1200C Dust Collector
JET EQUIPMENT & TOOLS, INC. P.O. BOX 1349 Phone:253-351-6000
A WMH Company Auburn, WA 98071-1349 Fax: 1-800-274-6840
www.jettools.com e-mail jet@jettools.com M-708634C 1/02
ページ2に含まれる内容の要旨
This manual has been prepared for the owner and operators of JET’S DC-1200C. Its purpose, aside from machine operation, is to promote safety through the use of accepted correct operating and maintenance procedures. Completely read the safety and maintenance instructions before operating or servicing the machine. To obtain maximum life and efficiency from your Dust Collector, and to aid in using the machine safely, read this manual thoroughly and follow instructions carefully. Warranty & Service
ページ3に含まれる内容の要旨
WARNING 1. Read and understand the entire contents of this manual before attempting assembly or operation. Do not use this machine until proper training and knowledge has been obtained. 2. Do not leave Dust Collector when plugged in. Unplug from outlet when not in use and before servicing. 3. Do not use outdoors or on wet surfaces. 4. Do not allow to be used as a toy. Close attention is necessary when used near children. 5. Use only as described in this manual. Use only manufacturer’s recommen
ページ4に含まれる内容の要旨
Specifications: DC-1200C Stock Number..............................................................................................................................708634C Blower Wheel Diameter........................................................................................................................12" Sound Rating at 3 feet................................................................................................................. 80-85 db Hose Diameter..........................
ページ5に含まれる内容の要旨
WARNING Read and understand the entire contents of this manual before attempting assembly or operation of the dust collector! Failure to comply may cause serious injury! Unpacking 1. Remove all contents from the shipping carton. 2. Report any damage to your distributor. 3. Do not discard any shipping material until after the dust collector has been assembled and is running properly. Contents of the Shipping Cartons Canister Filter Box 1. Canister Filter 1. Handle 1. Bag of Hardware for Handles
ページ6に含まれる内容の要旨
Assembly 1. Install four casters to the under side of the base as pictured in Fig. 1. Thread the hex nut (B, Fig. 1) onto the caster shaft. Then slide the lock washer (A, Fig. 1) over the caster shaft. Thread the caster shaft into the threaded hole on the underside of the base, turn until snug. Tighten the nut (B, Fig. 1) against the base with a 14mm wrench. This will give the caster proper clearance. 2. Place the base with casters on the ground. Attach the motor and fan assembly (A, Fig. 2) to
ページ7に含まれる内容の要旨
4. Attach three support brackets (A, Fig. 4) to the base using six M8 x 16 hex cap bolts and six M8 flat washers (B, Fig. 4). Hand tighten only at this time. 5. Install the housing (A, Fig. 5) to two support brackets using four M8 x 16 hex cap bolts, eight M8 flat washers, and four M8 hex nuts (B, Fig.5). Be sure hose opening faces fan housing. Before attaching third support bracket place the hanger bracket (C, Fig.5) between the support bracket and the housing. Tighten all nuts and bolts at thi
ページ8に含まれる内容の要旨
7. Place the ring over the top of the plastic bag and fold over the bag approximately three inches, Figure 7. 8. Insert the snap ring (A, Fig. 8) of the collector bag into the bottom of the housing at an angle. 9. Pull down on the ring to make sure it “seats” in the housing. Note: make sure the snap ring “snaps” into place in the housing, and also that the plastic bag hangs down approximately 3” so that there are no air leaks. 10. Mount the handle onto the canister filter with two M10 hex nuts,
ページ9に含まれる内容の要旨
Electrical Connections Removing the Collector Bag WARNING CAUTION All electrical connections must be done by a Wearing a particle mask/respirator for qualified electrician. All adjustments or protection against fine dust particles during repairs must be done with the dust collector cleaning is highly recommended. disconnected from the power source, unplugged. Failure to comply may result in 1. Disconnect the machine from the power serious injury! source, unplug. The DC-1200C dust collector is ra
ページ10に含まれる内容の要旨
Parts Breakdown for DC-1200C Dust Collector w/Canister Filter 10
ページ11に含まれる内容の要旨
Parts List for the DC-1200C Dust Collector w/Canister Filter Index Part No. No. Description Size Qty. 1..........708739......................... Filter...................................................... ...............................................1 2..........331010......................... Shaft...................................................... ...............................................1 3..........331012......................... Scraper...........................................
ページ12に含まれる内容の要旨
Index Part No. No. Description Size Qty. 53........TS-1490031................. Hex Head Bolt .......................................M8x20.....................................1 54........TS-1490011 ................. Hex Head Bolt .......................................M8x12.....................................4 55........TS-1490021 ................. Hex Head Bolt .......................................M8x16...................................16 56........TS-1490041 ................. Hex Head Bolt