ページ1に含まれる内容の要旨
Technical Information- Dishwasher
JDB4000AWB JDB4000AWQ JDB4000AWS JDB4000AWW
MDB5600AWB MDB5600AWQ MDB5600AWS MDB5600AWW
Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit. Refer to Service Manual 16021814.
CAUTION
!
All safety information must be followed as provided in Service Manual 16021814.
! WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher be
ページ2に含まれる内容の要旨
Component Specifications WARNING ! To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires it. Illustration Component Test Procedure Results Dishwasher Motor Measure resistance from ST5 (Motor Common – blue) to ST8 CCW rotation only (Motor Main - yellow). .......................... 3 to 4 Ω viewed from shaft See Component Specifications/Motor end. Connections for details. 1/3HP 120V/60hz,
ページ3に含まれる内容の要旨
Component Specifications WARNING ! To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires power. Illustration Component Test Procedure Results Limit Thermostat Close on Temperature drop @ 149°F ± 7°F (Temp) ...................................... 0 Ω = Closed Open on Temperature drop @ 164°F ± 4°F (Temp) ...................................... Infinite Ω = Open Sensor/Thermistor 10K
ページ4に含まれる内容の要旨
Component Readings/Testing WARNING ! To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires power. Manual Function Test Field Service Test A Manual Function Test may be started by pressing the Normal Wash key A Field Service Test may be started by pressing the Heavy Wash key 5 times 5 times followed by the Start key within 6 seconds. followed by the Start key within 6 seconds. This test must be performed with
ページ5に含まれる内容の要旨
Resistance Check Points and Values Disp. WM (2K**) Water Valve Thermistor (thru harness only with (1.1K**) connector unplugged)*** o (float switch *Vent WM Drain Motor 10K* +/- 3% @ 77 F must be closed) o (1.2K**) (25**) 2.4K* +/- 6.5% @ 140 F Pin # 1 23 45 6 7 8 Pin # 1 2 3 4 Stake Lug 11 10 9 87 6 5 4 3 21 WH WH OR RD RD AQ PU BK PU TN AQ YL GY BU BK BK RD BK J5 J6 Circuit Board Use the "Manual Function Test" [as described on the electric
ページ6に含まれる内容の要旨
Motor Connectivity WARNING ! To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires power. Wire harness Connection plug Blue (Common) Yellow (Main) Green (Ground) Red (Start) 1/3HP 120V/60hz, 3.2 amps, 3250 RPM 16023063 6 May 2004 ©2004 Maytag Services
ページ7に含まれる内容の要旨
Wiring Diagram WARNING ! To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires power. BK BK DOOR SWITCH (LI) CIRCUIT BOARD J6 PIN J5 PIN 1 1 RD BK BK BK BU GY YL WH WH AQ TN PU BK PU AQ RD RD OR BK BK RD BK BK BU GY YL WH WH AQ TN PU BK PU AQ RD OR BK OR RD AQ RD BK LI AQ GY PU WH BK PU WH PU BK WH TN WH TN AQ AQ YL YL RD RD RD OR PU AQ RD BK BK MOTOR CAPACITOR BK PU FLOAT SWITCH GR GY BK THERMOSTAT BK BU YL GR
ページ8に含まれる内容の要旨
DRY CYCLE (Models without 160° Wash option) FILL VENT CLOSED VENT OPENED RINSE ONLY CYCLE RINSE DRAIN FILL 1:36 min 5:00 2:00 0:02 HEATER HEATER HEATER HEATER HEATER HEATER HEATER HEATER HEATER HEATER HEATER HEATER HEATER HEATER HEATER HEATER 9 Minutes 1:46 max ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF 3:00 1:30 1:00 1:30 1:00 1:30 1:00 1:30 1:00 1:30 1:00 1:30 1:00 1:30 1:00 9:30 Available Options: No options are available with the Rinse Only cycle. Note:If i Heated Drysnotselecte