ページ1に含まれる内容の要旨
CHEMICAL SANITIZING, SINGLE AND DUAL RACK
UPRIGHT DOOR DISHMACHINES
INSTALLATION/OPERATION &
TECHNICAL MANUAL
FOR JACKSON MODELS:
CONSERVER XL, CONSERVER XL2
CONSERVER XL2-CML, CONSERVER XL2-CMR
CONSERVER AXL, CONSERVER AXL2
CONSERVER AXL2-CML, CONSERVER AXL2-CMR
Jackson MSC, LLC.
P.O. BOX 1060
HWY. 25E
BARBOURVILLE, KY. 40906
FAX (606) 523-9196
November 28, 2007
PHONE (606) 523-9795
P/N 7610-002-10-23 (Revision H)
www.jacksonmsc.com
ページ2に含まれる内容の要旨
MANUFACTURERS WARRANTY ONE YEAR LIMITED PARTS & LABOR WARRANTY ALL NEW JACKSON DISHWASHERS ARE WARRANTED TO THE ORIGINAL PURCHASER TO BE FREE FROM DEFECTS IN MATERIAL OR WORKMANSHIP, UNDER NORMAL USE AND OPERATION FOR A PERIOD OF (1) ONE YEAR FROM THE DATE OF PURCHASE, BUT IN NO EVENT TO EXCEED (18) EIGHTEEN MONTHS FROM THE DATE OF SHIPMENT FROM THE FACTORY. Jackson MSC agrees under this warranty to repair or replace , at its discretion, any original part which fails under normal use due to faul
ページ3に含まれる内容の要旨
STOP! PARE! ARRET! CALL 1-888-800-5672 TO REGISTER THIS PRODUCT! FAILURE TO DO SO WILL VOID THE WARRANTY! LLAME AL 1-888-800-5672 PARA REGISTRAR ESTE PRODUCTO! AL NO HACERLO LA GARANTIA SERA ANULADA! S.V.P. APPELER 1-888-800-5672 POUR ENREGISTRER CE PRODUIT, LA GARANTIE SERA ANNULEE POUR TOUT PRODUIT NON- ENREGISTREE 3
ページ4に含まれる内容の要旨
REVISION MADE APPLICABLE REVISION DETAILS DATE BY ECN F 05-07-04 MAW 7040 Added 2nd Enodis Logo. Changed to new layout. Added new parts for the redesigned Conserver XL unit. G 11-08-06 MAW N/A Added instructions and schematics for use with universal timers. H 11-28-07 MAW 7107, 7257, Converted to centered layout with bottom date stamp for revi- 7478, 7293, sions. Combined installation and technical manuals. Added bowl 7553, 7122, option and new style control box for universal timers. Combined 74
ページ5に含まれる内容の要旨
NOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL CONSERVER XL2-CMR Conserver XL = Low temperature, chemical sanitizing, single rack dishmachine Conserver XL2 = Low temperature, chemical sanitizing, dual rack dishmachine Conserver XL2-CML = Low temperature, chemical sanitizing, dual rack dishmachine with left hand feed through Conserver XL2-CMR = Low temperature, chemical sanitizing, dual rack dishmachine with right hand feed through Conserver AXL = Low temperature, chemical sanitizing, un
ページ6に含まれる内容の要旨
TABLE OF CONTENTS SECTION DESCRIPTION PAGE I. GENERAL Specifications for the Conserver XL 2 Specifications for the Conserver XL2 Series 3 Dimensions Conserver AXL (Universal Timer) 4 Dimensions Conserver AXL2 (Universal Timer) 5 Dimensions Conserver AXL2-CML (Universal Timer) 6 Dimensions Conserver AXL2-CMR (Universal Timer) 7 Dimensions Conserver XL (Starting with S/N 04D10286) 8 Dimensions Conserver XL2 9 Dimensions Conserver XL2-CML 10 Dimensions Conserver XL2-CMR 11 Conserver AXLS Option 12
ページ7に含まれる内容の要旨
TABLE OF CONTENTS VI. ELECTRICAL DIAGRAMS Conserver AXL (115 Volt, 60 Hz, Single Phase) 70 Conserver AXL2 (115 Volt, 60 Hz, Single Phase) 71 Conserver AXL2 CML/CMR (115 Volt, 60 Hz, Single Phase) 72 Conserver AXL2 CML/CMR (208-230 Volt, 60 Hz, Single Phase) 73 Conserver AXLS (115 Volt, 60 Hz, Single Phase) 74 Conserver AXLS2 CML/CMR (115 Volt, 60 Hz, Single Phase) 75 Conserver XL (115 Volt, 60 Hz, Single Phase) 76 Conserver XL (220 Volt, 50 Hz, Single Phase) 77 Conserver XL2 (115 Volt, 60 Hz, Si
ページ8に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION 1
ページ9に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION CONSERVER XL SPECIFICATIONS PERFORMANCE/CAPABILITIES ELECTRICAL REQUIREMENTS OPERATING CAPACITY (RACKS/HOUR) WASH PUMP MOTOR HORSEPOWER 3/4 RACKS PER HOUR 37 DISHES PER HOUR 925 GLASSES PER HOUR 925 NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical OPERATING CYCLE (SECONDS) fixed-trip circuit breaker sizes as listed in the NEC 2002 WASH TIME 42 Edition. Local codes may require more stringent prote
ページ10に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION CONSERVER XL2 SERIES SPECIFICATIONS PERFORMANCE/CAPABILITIES ELECTRICAL REQUIREMENTS OPERATING CAPACITY (RACKS/HOUR) WASH PUMP MOTOR HORSEPOWER 3/4 RACKS PER HOUR 74 RACKS PER HOUR (OPTION) 96 DISHES PER HOUR 1850 NOTE: Typical Electrical Circuit is based upon (1) 125% GLASSES PER HOUR 1850 of the full amperage load of the machine and (2) typical fixed-trip circuit breaker sizes as listed in the NEC 2002 OPERATING CYCLE (SECONDS) Edition. Local codes may requ
ページ11に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION DIMENSIONS CONSERVER AXL Standard clearance between the wall and the machine with 3 [77mm] dishtable is 4". LEGEND: A - Electrical connection 1 [28mm] B - Water inlet 1/2" I.P.S C - Drain connection 2" I.P.S 1 13 [334mm] 4 All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. 32 3/4 [832mm] With doors open 32 [813mm] A 6 [155mm] B 3 6 [174mm] 4 78 [1981mm] 1 17 [438mm] 4 Maximum Dish 57 1/4 [1454 mm] Clearance 65 1/4 [1658mm] 68 1/2
ページ12に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION DIMENSIONS CONSERVER AXL2 2 [52mm] B 4 [102mm] 1 11 [286mm] 4 25 [636mm] B 44 [1117mm] 78 [1981 mm] 1 57 [1453mm] 4 1 LEGEND: 65 [1658mm] 4 A - Electrical connection B - Water inlet 1/2" I.P.S C - Drain connection 2" I.P.S All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. C 13 [330 mm] 1 50 [1286mm] 2 1 15 [387mm] 4 A 3 6 [171mm] 4 1 68 [1740mm] 2 1 17 [438mm] 4 MAXIMUM DISH CLEARANCE 34 [864mm] 1 11 [283mm] 4 C Conserver XL Ser
ページ13に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION DIMENSIONS CONSERVER AXL2-CML LEGEND: B A - Electrical connection B - Water inlet 1/2" I.P.S 78 [1981mm] C - Drain connection 2" I.P.S 1 65 [1658mm] 4 All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. 1 B 11 [295mm] 2 4 [102mm] 1 13 [337mm] A 4 25 [635mm] 13 [330mm] C 44 [1118mm] 48 1/2 [1232MM] 1 15 [387mm] 4 A 6 3/4 [171 mm] 68 1/2 [1740 mm] 1 17 [438mm] 4 MAXIMUM DISH CLEARANCE 34 [864mm] 11 1/4 [283 mm] C Conserver XL Series
ページ14に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION RDIMENSIONS CONSERVER AXL2-CMR LEGEND: B A - Electrical connection B - Water inlet 1/2" I.P.S C - Drain connection 2" I.P.S All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. 78 [1981mm] 1 65 [1658mm] 4 B 1 11 [295mm] 2 4 [102mm] 1 13 [337mm] 4 [635mm] A 13 [330mm] C 44 [1118mm] 48 1/2 [1232mm] 1 15 [387mm] 4 A 6 3/4 [171mm] 68 1/2 [1740mm] 1 17 [438mm] 4 MAXIMUM DISH CLEARANCE 34 [864mm] 11 1/4 [283mm] C Conserver XL Series Insta
ページ15に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION DIMENSIONS CONSERVER XL (Starting with S/N 04D10286) 4 [105mm] LEGEND A - ELECTRICAL CONNECTION D B - WATER INLET, 3/4" IPS EDGE OF WATER INLET C - DRAIN CONNECTION, 2" IPS TO SIDE OF MACHINE D - STANDARD CLEARANCE BETWEEN 1 1 [40mm] MACHINE AND WALL (WITH DISHTABLE) 2 IS 4" [105mm] B ALL DIMENSIONS ARE +/- 1/2" FROM FLOOR DUE TO ADJUSTABLE BULLET FEET. 1 [25mm] 1 4 [117mm] 2 C L OF WATER INLET BACK OF CONTROL BOX TO BACK OF MACHINE TO BACK OF MACHINE SIDE OF
ページ16に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION DIMENSIONS CONSERVER XL2 Conserver XL Series Technical Manual 7610-002-10-23 Issued: 11-28-2007 Revised: N/A 9 3 3 A 4 [121mm] 11 [301mm] 4 4 B 1 4 [112mm] 2 LEGEND MINIMUM A - ELECTRICAL CONNECTION 1 B - WATER INLET, 3/4" IPS 4 [113mm] 1 [24mm] 2 C - DRAIN CONNECTION, 2" IPS ALL DIMENSIONS ARE +/- 1/2" FROM FLOOR DUE TO 26 [663mm] ADJUSTABLE BULLET FEET. 44 [1116mm] A B B 00000000 5 [129mm] 2 1 17 [441mm] 2 66 [1679mm] 3 75 [1922mm] 4 61 [1548mm] 1 56 [143
ページ17に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION DIMENSIONS CONSERVER XL2-CML 3 11 [296mm] 4 LEGEND A - ELECTRICAL CONNECTION 1mm] B - WATER INLET, 3/4" IPS C - DRAIN CONNECTION, 2" IPS 32 [814mm] B ALL DIMENSIONS ARE +/- 1/2" FROM FLOOR DUE TO 26 [662mm] ADJUSTABLE BULLET FEET. A 3 20 [527mm] 4 4 [101mm] 3 20 [526mm] 4 44 [1115mm] 1 46 [1176mm] 4 1 4 [111mm] 2 1 [24mm] A B 00000000 14 [355mm] A 1 60 [1534mm] 2 5 [127mm] 3 75 [1921mm] 4 66 [1679mm] 1 17 [445mm] 2 1 56 [1438mm] 2 34 [863mm] C 1 13 [333mm] 10
ページ18に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION DIMENSIONS CONSERVER XL2-CMR 3 11 [296mm] 4 4 [101mm 32 [814mm] B LEGEND 26 [662mm] A - ELECTRICAL CONNECTION 3 20 [527mm] B - WATER INLET, 3/4" IPS 4 C - DRAIN CONNECTION, 2" IPS ALL DIMENSIONS ARE +/- 1/2" FROM FLOOR DUE TO ADJUSTABLE BULLET FEET. 4 [101mm] 3 20 [526mm] 4 1 44 [1130mm] 2 1 48 [1232mm] 1 2 4 [112mm] 2 1 [24mm] A B B A 1 60 [1536mm] 2 5 [125mm] 66 [1677mm] 3 75 [1925mm] 4 1 17 [444mm] 2 1 56 [1437mm] 2 34 [863mm] 34 [863mm] C 13 [328mm] 1 10
ページ19に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION XLS BOWL OPTION Legend A - Electrical Connection 1 B - Water Connection, " 4 1 21 [545mm] 2 18 [459mm] Bowl Option - Front Side View 8 [202mm] 1 A [13mm] 2 B 1 5 [134mm] 5 [128mm] 4 Bowl Option - Right Side View Conserver XL Series Technical Manual 7610-002-10-23 Issued: 11-28-2007 Revised: N/A 12
ページ20に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION TABLE DIMENSIONS 4” (102mm) MINIMUM TABLE DIMENSIONS CORNER INSTALLATION 20 1/2” (521mm) 2 1/2” (63mm) OPENING 25 1/4” 4” (102mm) MINIMUM (641mm) 3/4” (19mm) 1 1/2” (381mm) ROLL TABLE DIMENSIONS 20 1/2” (521mm) CONNECTION TO DISHMACHINE 4” (102mm) MINIMUM 25 1/4” (641mm) 44” (1117mm) TABLE DIMENSIONS XL SERIES XL2 SERIES STRAIGHT THROUGH INSTALLATION Conserver XL Series Technical Manual 7610-002-10-23 Issued: 11-28-2007 Revised: N/A 13 25 1/4” (64.1mm) 20