ページ1に含まれる内容の要旨
HOT WATER SANITIZING UNDERCOUNTER DISHMACHINES
TECHNICAL MANUAL
INSTALLATION MANUAL FOR EXPORT UNITS
SERVICE MANUAL FOR DOMESTIC UNITS
FOR JACKSON MODELS:
JP-24
JP-24F
JP-24B
JP-24BF
An Company
Jackson MSC, Inc.
P.O. BOX 1060
HWY. 25E
BARBOURVILLE, KY. 40906
FAX (606) 523-9196
March 6, 2006
PHONE (606) 523-9795
P/N 7610-002-49-79 (Revision D)
www.jacksonmsc.com
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
REVISION MADE APPLICABLE REVISION DETAILS DATE BY ECN A 07-15-2002 MAW 6527 Release manual for service use. 6673, 6681 B 06-04-2003 MAW Updated per ecns. 6637 C 02-11-2004 MAW 6836 Updated per ecns. Change thermostat from 05930-121-71-29 to 05930-510-03-79. Change thermostat from 05930-121-71-36 to 05930-011-49-43. 7421, 7231 Change Diverter Valve Assembly number from 05700-002-23-21 D 03-06-2006 MAW 6964, 7095 to 06410-012-23-21 & Diverter Valve Assembly 05700-002-23-22 to 06401-022-23-21. Repl
ページ4に含まれる内容の要旨
NOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL JP-24B JP-24 = Undercounter, high temperature, hot water sanitizing, no booster tank. JP-24F = Undercounter, high temperature, hot water sanitizing, no booster tank, with top and side panels. JP-24B = Undercounter, high temperature, hot water sanitizing, with a booster tank. JP-24BF = Undercounter, high temperature, hot water sanitizing, with a booster tank, with top and side panels. Jackson MSC Inc. provides technical support for all Model:
ページ5に含まれる内容の要旨
TABLE OF CONTENTS SECTION DESCRIPTION PAGE I. SPECIFICATION INFORMATION Specifications JP-24/JP-24F 2 Specifications JP-24B/JP-24BF 3 Dimensions 4 II. INSTALLATION/OPERATION INSTRUCTIONS Installation Instructions 6 Electrical Installation Instructions 7 Operation Instructions 8 Detergent Control 9 Cycle Counter Retrofit Kit Instructions 10 III. PREVENTATIVE MAINTENANCE Preventative Maintenance 12 IV. TROUBLESHOOTING 14 V. SERVICE PROCEDURES Rinse Solenoid Valve Repair Parts Kit 17 Vacuum Breake
ページ6に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION 1
ページ7に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION SPECIFICATIONS of the JP-24/JP-24F ELECTRICAL REQUIREMENTS PERFORMANCE/CAPABILITIES WASH MOTOR HP 3/4 OPERATING CAPACITY (RACKS/HOUR) RACKS PER HOUR 30 NOTE: Typical Electrical Circuit is based upon (1) 125% of the DISHES PER HOUR 600 full amperage load of the machine and (2) typical fixed-trip cir- cuit breaker sizes as listed in the NEC 2002 Edition. Local GLASSES PER HOUR 600 codes may require more stringent protection than what is dis- played here. Always
ページ8に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION SPECIFICATIONS of the JP-24B/JP-24BF PERFORMANCE/CAPABILITIES ELECTRICAL REQUIREMENTS OPERATING CAPACITY (RACKS/HOUR) WASH MOTOR HP 3/4 RACKS PER HOUR 30 NOTE: Typical Electrical Circuit is based upon (1) 125% of the DISHES PER HOUR 600 full amperage load of the machine and (2) typical fixed-trip cir- cuit breaker sizes as listed in the NEC 2002 Edition. Local GLASSES PER HOUR
ページ9に含まれる内容の要旨
SECTION 1: SPECIFICATION INFORMATION JP-24 DIMENSIONS 2 1/2” (6.4 cm) Min. Wall Clearance LEGEND A - Water Inlet 1/2” ID Female Pipe Thread, 2 1/2” AFF B - Detergent Feeder Connection C - Electrical Connection E D - Drain Connection Flexible Hose 6’ Free 12” Length, 19” (30.5 cm) 1” ID x 1 3/8” OD (48.3 cm) E - Rinse Additive Connection 22 5/8” (57.5 cm) A C 16 3/4” DOOR OPEN (42.5 cm) 6 1/2” (16.5 cm) 24 1/4” D E (61.6 cm) 4 1/2” (11.4 cm) B 33 1/4” C (84.5 cm) 13 1/4” A (33.7 cm) 8 1/2”
ページ10に含まれる内容の要旨
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS 5
ページ11に含まれる内容の要旨
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION INSTRUCTIONS VISUAL INSPECTION: Before installing the unit, check the container and machine for damage. A damaged container is an indi- cator that there may be some damage to the machine. If there is damage to both the container and machine, do not throw away the container. The dishmachine has been inspected and packed at the factory and is expected to arrive to you in new, undam- aged condition. However, rough handling by carriers or o
ページ12に含まれる内容の要旨
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS ELECTRICAL INSTALLATION INSTRUCTIONS ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with the applicable portions of the National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes. Disconnect electrical power supply and place a tag at the disconnect switch to indicate that you are working on the circuit. The dishmachine data plate is located on the front of the machine. Refer to the data plate
ページ13に含まれる内容の要旨
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS OPERATION INSTRUCTIONS PREPARATION: Before proceeding with the start-up of the unit, verify the following: 1. The strainer is in place and is clean. 2. That the wash and rinse arms are screwed securely into place and that their endcaps are tight. The wash and rinse arms should rotate freely. POWER UP: To energize the unit, turn on the power at the service breaker. The voltage should have been previously verified as being correct. If not, the voltag
ページ14に含まれる内容の要旨
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS DETERGENT CONTROL Detergent usage and water hardness are two factors that contribute greatly to how efficiently your dishmachine will operate. Using detergent in the proper amount can become, in time, a source of substantial savings. A qualified water treatment spe- cialist can tell you what is needed for maximum efficiency from your detergent, but you should still know some basics so you’ll understand what they are talking about. First, you must un
ページ15に含まれる内容の要旨
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CYCLE COUNTER RETROFIT KIT INSTRUCTIONS 1. Locate the template on the front of the plastic control panel in the approximate location as shown in the diagram below. 2. Use a 3/32" diameter drill bit to drill the four mounting holes through the plastic control panel. 3. Mount the template to the front of the control panel using the screws and locknuts provided. 4. Using the template as a guide, cut the 1-3/8" x 1-1/8" cutout (the inside of the tem
ページ16に含まれる内容の要旨
SECTION 3: PREVENTATIVE MAINTENANCE 11
ページ17に含まれる内容の要旨
SECTION 3: PREVENTATIVE MAINTENANCE PREVENTATIVE MAINTENANCE The dishmachines covered in this manual are designed to operate with a minimum of interaction with the operator. However, this does not mean that some items will not wear out in time. Jackson highly recommends that any maintenance and repairs not specifically discussed in this manual should be performed by QUALIFIED SERVICE PERSONNEL ONLY. Performing main- tenance on your dishmachine may void your warranty if it is still in effect. The
ページ18に含まれる内容の要旨
SECTION 4: TROUBLESHOOTING 13
ページ19に含まれる内容の要旨
SECTION 4: TROUBLESHOOTING SECTION COMMON PROBLEMS WARNING: Inspection, testing and repair of electrical equipment should be performed only by qualified service personnel. Certain procedures in this section require electrical tests or measurements while power is applied to the machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect power, attach test equipment and reapply power to test. When replacing electrical parts, disconnect power at source cir
ページ20に含まれる内容の要旨
SECTION 4: TROUBLESHOOTING SECTION COMMON PROBLEMS WARNING: Inspection, testing and repair of electrical equipment should be performed only by qualified service personnel. Certain procedures in this section require electrical tests or measurements while power is applied to the machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect power, attach test equipment and reapply power to test. When replacing electrical parts, disconnect power at source cir