ページ1に含まれる内容の要旨
MODEL GL-C
INSTALLATION & OPERATION
Rev. 1.00A
CMA DISHMACHINES
12700 KNOTT AVENUE
GARDEN GROVE, CALIFORNIA 92841
800-854-6417
FAX 714-895-2141
www.cmadishmachines.com
ページ2に含まれる内容の要旨
TABLE OF CONTENTS MODEL GL-C 1. RECEIVING ...................................................................................................2 2. SPECIFICATIONS .........................................................................................3 3. INSTALLATION.............................................................................................4 3.1. ELECTRICAL .....................................................................................................................
ページ3に含まれる内容の要旨
Receiving 1. Receiving 1. Remove the packing material from the top of the conveyor stack. 2. Remove all packing material and tape securing components within the machine. Check that both trays are positioned properly. 3. Check for the following component parts: A. Check that the deflector screen is secure in the rinse drain. B. Check the position of the GL-C curtain. C. Check that the conveyor is level and the drive gear is engaged in the conveyor’s outer rim groove
ページ4に含まれる内容の要旨
Specifications 2. Specifications WATER CONSUMPTION HOT WATER INITIAL FILL 3 GAL. 11.35 L. HOT WATER PER HOUR (max) 12 GAL. 45.42 L. COLD WATER PER HOUR 168 GAL. 636 L. OPERATING CAPACITY (2-1/2”) GLASSES PER HOUR 1000 - WATER REQUIREMENTS COLD WATER INLET 1/2” - HOT WATER INLET 1/2” - DRAIN CONNECTION 1-1/2” - TEMPERATURES INLET COLD WATER 75
ページ5に含まれる内容の要旨
Instructions 3. Installation * 3.1. Electrical A 15 Amp, 240 Volt, 60 Hz dedicated circuit should be used to supply electrical power to the GL-C machine (see specification sheet page 2). The power connection with the leads L-1,L-2 and Ground must be such that there is sufficient length of flexible conduit to permit the machine to be moved for cleaning. This machine operates from 208 to 240 Volts. * 3.2. Plumbing Hot Water Connection 1.
ページ6に含まれる内容の要旨
Flow Diagram 4. GLC Flow Diagram MODEL GL-C Installation & Operation Manual Rev. 1.00 –2/23/06 Page 5
ページ7に含まれる内容の要旨
Operation 5. Operation 5.1. Filling the Wash Tank • Ensure that the overflow drain tube is in place in the detergent tank. • Flip power on-off/flush switch to the “ON” position. The water will fill until the proper level is reached then turn the heating element “ON”. • The water temperature is controlled by a heater and a thermostat .The ther
ページ8に含まれる内容の要旨
Operation To Adjust Rinse Agent Injector: • When a new rinse agent container is installed, push the prime button in and hold until the rinse injector feed tube is full. • Start the washer. Take a sample from the final rinse spray tubes. • To increase the volume of rinse agent, turn the adjustment screw clockwise. • To decrease the volume of rinse agent, turn the adjustment screw counter-clockwise. Note:To meet the requirements of N.S.F. standards, Iodophor in a c
ページ9に含まれる内容の要旨
Maintenance 6. Maintenance 6.1. Troubleshooting PROBLEM LIKELY CAUSE SOLUTION Conveyor doesn’t turn Power off at circuit breaker Reset circuit breaker Drive motor burn out Replace drive motor Remove obstruction Obstruction in wash or rinse Replace or adjust Micro switch on switch support bracket faulty or not making contact Position properly Conveyor not in position Excessive overspray from Splash curtain not in position Install or adjust hood section Washer running without an
ページ10に含まれる内容の要旨
Maintenance PROBLEM LIKELY CAUSE SOLUTION Lack of pressure in rinse Rinse solenoid valve will not Check coil spray tube operate Check and install rebuild kit Replace if necessary Rinse solenoid valve strainer Remove screen and clean plugged Water continues to flow to Solenoid valve not sealing Clean seat detergent tank or spray Install diaphragm kit tubes with machine off Replace valve Adjust thermostat Water temperature low in Thermostat setting low detergent tank Thermosta
ページ11に含まれる内容の要旨
RINSE SANI DETERGENT PRIMER PRIMER PRIMER 6 1 3 2 Electrical Diagram 7. Electrical Diagram MODEL GL-C Installation & Operation Manual Rev. 1.00A –2/23/06 Page 10 CONVEYOR HU S T-OFF SWITCH CONVEYOR 1 3 1 2 NC NC MOTOR 4 6 3 4 NO NO ROCKER SWITCH 7 C 9 5 C 6 FLOAT A 7 B 8 SWITCH PUMP MOTOR 240V WASH SOLENOID VALVE ANSFOR R TR ME POWER FLUSH 24V ON/OFF DET CIRCUIT BOARD HEATER RINSE SANI SOLENOID VALVE