Condensed Operating Manual for Door Control Unit AT8
SIDOOR
Condensed Operating Manual AT18
Rev. 09, Issue Date 8/2007
www.siemens.de/edm
ページ2に含まれる内容の要旨
Condensed Operating Manual for Door Control Unit AT8 1 Overview of operating elements Substructure group AT8: X1: A uxiliar y module flat cable connection X3: Mains current transformer connection X4: Current output 4V / 0.4A X5: Emergency power module input signal X6: Input signals connection - Light barrier - Nudge - Close - Open X7: Motor plug X8: Connection for user terminal and USB adapter (AT Frontend PC) H5000: 7-segment display for door sta
ページ3に含まれる内容の要旨
Condensed Operating Manual for Door Control Unit AT8 2 Safety instructions WARNING Only qualified personnel should work on or be in the vicinity of this equipment. This staff must be thoroughly familiarized with all warnings and maintenance procedures according to the operating manual. 3 Mechanical installation and configuration . Mount the motor on the motor mounting (rubber-bonded metal/vibration shock mount). Thereafter the motor is mounted on the mounting bracket if necessary. . M
ページ4に含まれる内容の要旨
Condensed Operating Manual for Door Control Unit AT8 . Connect the light barrier to X6 (see illustration or lid imprint). Insofar as the light barrier input is not used, X6 must be wired to X4 according to the lines on the connection layout. 3. Plug in clip plugs X6 and X4. CAREFUL The control is operative after the next switch-on. At a presented control signal the door moves into the specified dir ection. 4. Switch control on (plug in mains current plug, or plug X3). The four L
ページ5に含まれる内容の要旨
Condensed Operating Manual for Door Control Unit AT8 in the bottom right corner of the display. 6. With a short pressing of the red parameter button (S5000) one can switch to parameter “A” (counterweight). The alternatively displayed numerical value represents the counterweight in kg (adjustment range 0 kg to 6 kg). It can be adjusted with the service button – “OPEN” and – “CLOSE” (S500, or S500). 7. The set value is saved by a long pressing of (>s) of the parameter button (S5000). 8.
ページ6に含まれる内容の要旨
Condensed Operating Manual for Door Control Unit AT8 7 Parameter setting with terminal module or user terminal The terminal module (option) or the user terminal can equally be used for the diagnosis and setting of t he par ame t er . The butt ons of t he t ools ha v e identical designations and significance. Accept key, jump to next menu below Escape key, jump back to menu above ESC Menu selection key, increase of a parameter value Menu selection key, reducing of a parameter
ページ7に含まれる内容の要旨
Condensed Operating Manual for Door Control Unit AT8 7
ページ8に含まれる内容の要旨
Condensed Operating Manual for Door Control Unit AT8 Ýçindekiler Ýçindekiler ........................................................................................................... Giriþ .....................................................................................................................4 3 Güvenlik notlarý ...................................................................................................5 3. Genel güvenlik bilgileri .............................