ページ1に含まれる内容の要旨
Installation
Instructions
RCW35 and RCW25 Series (51366SL)
Decorative Wired Chimes
RCW250N, RCW251N, RCW35N,
RCW3501N, RCW3502N, RCW3503N,
RCW3504N, RCW3505N, RCW3506N
69-2173EFS-03
69-2173EFS_B.indd 1 4/17/2008 11:15:45 AM
ページ2に含まれる内容の要旨
Installation Instructions Contents Safety ............................................................................................................................................. 3 Checking pack contents ............................................................................................................... 4 Installation ..................................................................................................................................... 5 Power supply ..............
ページ3に含まれる内容の要旨
RCW35 Series and RCW25 Series VOLUME CONTROL PROGRAM BUTTON CHANNEL INDICATOR LED TUNE BUTTON WIRE CONNECTION PORT/TERMINAL LOW BATTERY HOLE FOR LED CABLE/WIRE ENTRY OPTIONAL POWER WITH FOUR x LR14C ALKALINE BATTERIES WIRED CHIME BASE DECORATIVE CHIME COVER SOLD SEPARATELY FROM RCW35N M27274 M27254 1 69-2173EFS—03 69-2173EFS_B.indd 1 4/17/2008 11:15:45 AM
ページ4に含まれる内容の要旨
Installation Instructions Compatible with most bell pushes, with standard normally open contacts, including Honeywell wired pushes marked with “B.” Can work with up to 3 push circuits. Illuminated bell push buttons can be used when the chime is powered by a trans- former (Honeywell RCA900N). 69-2173EFS—03 2 69-2173EFS_B.indd 2 4/17/2008 11:15:45 AM
ページ5に含まれる内容の要旨
RCW35 Series and RCW25 Series Safety Before proceeding with the installation, please note the following safety warnings: • Always follow the manufacturer’s advice when using power tools and wear suitable protective equipment (e.g. safety goggles) when drilling holes, etc. • Before drilling holes in walls, check for hidden electricity cables and water pipes. The use of a cable/pipe locator is advisable if in doubt. • Chime is for indoor use only. • Avoid mounting location which can expose c
ページ6に含まれる内容の要旨
Installation Instructions Checking Pack Contents • Chime • 2 x fixing screws for chime • 2 x wall plugs You will need: • Wired push • 20 AWG minimum bell wire • 4 mm cross-head screwdriver • A small flat bladed screwdriver • 1/4-in. (6 mm) masonry drill bit • 4 x LR14 ‘C’ Alkaline batteries OR transformer (16V 10 VA) Honeywell part number RCA900N 69-2173EFS—03 69-2173EFS_B.indd 4 4/17/2008 11:15:45 AM
ページ7に含まれる内容の要旨
RCW35 Series and RCW25 Series Installation 1. Open the chime cover M27275 5 69-2173EFS—03 69-2173EFS_B.indd 5 4/17/2008 11:15:45 AM
ページ8に含まれる内容の要旨
Installation Instructions Power Supply 2. Determine the type of power supply and type of wired push required to suit your installation. Use 4 x LR14 ‘C’ size alkaline batteries; OR a 16V, 10VA transformer as recommended in the table below below: ATTENTION! 1 2 3 ATTENTION! ¡ATENCIÓN! 16 V~ M27276 69-2173EFS—03 6 69-2173EFS_B.indd 6 4/17/2008 11:15:45 AM T
ページ9に含まれる内容の要旨
RCW35 Series and RCW25 Series Mount the Chime 3. Mounting holes are marked with a screw symbol. � 2 M 6 FT � M27250 7 69-2173EFS—03 69-2173EFS_B.indd 7 4/17/2008 11:15:45 AM
ページ10に含まれる内容の要旨
Installation Instructions Wiring OPTION 1: AC POWERED DO NOT USE BATTERIES Connect the wires from door push and trans- x 1 x 3 former (where used) to the chime terminals as detailed in step 4. The wires can be surface 120V~ 16V~ mounted or direct from opening in the wall and enter the rear of the chime housing using AC V/AC C1 C2 C3 the wire guide channels provided. 4a. Transformer powered - Wiring for 1 standard/lighted push via a 16V 10VA transformer. 16V~ 2 3 120V~ M27279 69-2173EFS—0
ページ11に含まれる内容の要旨
RCW35 Series and RCW25 Series OPTION 2: SERIES AC CONNECTION REQUIRED BATTERIES Note: Wire/cable x 1 x 3 length should not exceed 150 ft. (50 m). 120V~ 16V~ AC V/AC C1 C2 C3 1 16V~ 2 3 120V~ M27280 9 69-2173EFS—03 69-2173EFS_B.indd 9 4/17/2008 11:15:45 AM
ページ12に含まれる内容の要旨
Installation Instructions 4b. Battery powered - Wiring for x 1 standard (non-lighted) push only. x 3 Note: Wire/cable length should not exceed 150 ft. (50 m). AC V/AC C1 C2 C3 1 2 3 M27281 69-2173EFS—03 10 69-2173EFS_B.indd 10 4/17/2008 11:15:46 AM
ページ13に含まれる内容の要旨
RCW35 Series and RCW25 Series Operate Push 5. Chime will play the default tune. The associated channel LED will illuminate. 6. To adjust volume. M27277 11 69-2173EFS—03 69-2173EFS_B.indd 11 4/17/2008 11:15:46 AM
ページ14に含まれる内容の要旨
Installation Instructions To Change Tune 7. Chime tunes are provided plus an additional alert tone. Tunes Table Ding Dong St Clements Westminster Tube Chime Warm Brass Fantasy Alert ! 69-2173EFS—03 12 69-2173EFS_B.indd 12 4/17/2008 11:15:46 AM
ページ15に含まれる内容の要旨
RCW35 Series and RCW25 Series Press push button, chime will play tune, while the Channel LED on chime is flashing, press and release tune button . Press and release button again to cycle through the available tunes until you hear the tune you want to play. The last tune played will be stored after Channel LED stops flashing. To confirm, press the push button and chime will play tune you want. ! M27278 13 69-2173EFS—03 69-2173EFS_B.indd 13 4/17/2008 11:15:46 AM
ページ16に含まれる内容の要旨
Installation Instructions Program Button 8. The Program button can be used to: • Change the tune of the associated push without pressing the push button. Press and hold the program button l. The channel LED will illuminate in sequence. Release the program button when channel LED for the related push illuminates. The chime will play the latest tune, channel LED will flash. While channel LED is flashing, tune can be changed using the tune select button . • Recall A short push of the progra
ページ17に含まれる内容の要旨
RCW35 Series and RCW25 Series 9. Clip on the front cover. 10. For customizable wood covers only: Choose your paint, wood stain/ varnish or wall paper and then apply to the cover. Follow manufacturers’ advice on the paint/vanish. It is possible to unscrew the four screws shown below for finishing. Ensure you screw it back with the same screws provided! Once completed, clip it onto the base. M27251 15 69-2173EFS—03 69-2173EFS_B.indd 15 4/17/2008 11:15:46 AM
ページ18に含まれる内容の要旨
Installation Instructions Specification Chime Operating Temperature 32°F to 104°F 0°C to +40°C Sound Level (typical) 90dBA @ 3 ft (1m) Power Supply 4 x LR14 C size alkaline batteries OR 16V 10VA transformer (UL approved) Honeywell part number RCA900N Battery Life (if applicable) 12 months (5 operations/day) 69-2173EFS—03 16 69-2173EFS_B.indd 16 4/17/2008 11:15:46 AM
ページ19に含まれる内容の要旨
RCW35 Series and RCW25 Series Troubleshooting When the illuminated bell push is operated, very dim / no light appears on the push… Check the power supply. You should use a 16V 10VA transformer connection for an illuminated push. Follow step 4. The chime does not work… • Check that the wiring is done correctly according to step 4, using minimum 20AWG wire. If using batteries: • Check that the batteries are the correct type, LR14 ‘C’ cells. Only use alkaline batteries. • Check that the batte
ページ20に含まれる内容の要旨
Installation Instructions Disposal & Recycling Batteries and waste electrical products should not be disposed of with household waste. Please recycle where these facilities exist. Check with your local authority or retailer for recycling advice. Guarantee Honeywell guarantees this product for 1 year from the date of purchase. Proof of purchase is required; this does not affect your statutory rights. If you require further information about your product, call the Honeywell helpline at 1-800-4