ページ7に含まれる内容の要旨
You can turn on the unit by setting the [POWER] switch Preparation of output channels on the front panel to “INT” (upper position) or “EXT” (lower position). When you operate the unit on internal battery (1) Connect an external audio device such as a power, set the switch to “INT”. recorder to the [MAIN OUT] connectors (L and R). When you operate the unit on external power, set it to (2) Set the output level switch appropriately depending “ E X T ” . W h e n y o u t u r n o n
ページ8に含まれる内容の要旨
Preparation of monitoring : I n t h e f o l l o w i n g fi g u r e s , t h e m e t e r n e e- dles point the reference (0 VU). (1) Connect headphones to the 1/4-inch [PHONES] jack on the front panel or the mini-phone [PHONES] jack on the right side panel. You can use both the 1/4-inch and mini-phone jacks simultaneously. (2) Set the monitor select switch to “ST” and adjust the monitor level using the [PHONE] control. Stereo metering Mono metering (4) After
ページ9に含まれる内容の要旨
Block diagram 9
ページ10に含まれる内容の要旨
Names and functions Front panel section 1. PEAK indicators (1 through 3) Each indicator lights according to the signal level of the corresponding input channel as follows. Lighting level Color Details (compared with the reference level) : For details about the contents of the dis- Approximately -12dB below play, see “Display details” on page 14. Green +8dB the internal maximum level Approximately -3dB below Red +17dB 5. [SLATE] switch (1k / OFF / MIC) the internal maximum level W
ページ11に含まれる内容の要旨
10. Monitor select switch : When you select the [LIMITER] switch to This switch selects the signal monitored by the ON or LINK, the meter display shows “LIM” (pointed headphones connected to the [PHONE] jacks (1/4-inch by arrows below). When the limiter is working, “LIM” and mini). fl a s h e s . T h e f o l l o w i n g s h o w s d i s p l a y e x a m p l e s o f t h e stereo meter display. AUX Signals input to the [AUX IN] connector. When the switch is set to OF
ページ12に含まれる内容の要旨
Left side panel section 1. [INPUT] connector (1 through 3) 5. Microphone power supply switches (T12 / DM /P48) Each switch sets whether or not supplying the Each connector is used to connect an external audio device or microphone. microphone power. Connector: XLR-3-31 type T12 or AB power supply mode. A 12 V power is sup- plied to the hot terminal of the [INPUT] connector. 1 GND T12 : If you do not need T12 power supply, 2 HOT you can disable the power supply via the input 3
ページ13に含まれる内容の要旨
Right side panel section 1. [MAIN OUT] (L, R) connectors 7. AUX OUT level select switch These connectors output stereo buss L and R signals. This switch selects the output reference level of the You can select the output reference level using the [AUX OUT] connector between -10 dBV and -60 dBV. MAIN OUT level select switch described below. 8. AUX OUT select switch Connector: XLR-3-32 type This switch selects the output signal source of the [AUX OUT] connector. GND 1 No signal
ページ14に含まれる内容の要旨
(2) Press the [-] key to lower the brightness or press Display the [+] key to increase the brightness. You can select from OFF and 1 through 5. The display on the front panel of the unit normally Brightness shows the VU and peak meters. You can select stereo or mono metering. The display also can show the status Turning off the 1 2 3 4 5 display of inputs, outputs, etc., which you can edit. You can also adjust the display brightness to match the circumstance. [-] key (darker) [+] ke
ページ15に含まれる内容の要旨
Selecting the meter mode Selecting the status display In the status display mode, not only you can check the You can select the meter mode from stereo, mono L and mono R. By default, it is set to the stereo mode. status for the input, output, meter and system, but also you can edit setting. The meter mode setting remains even after you turn o f f t h e u n i t . I f y o u i n i t i a l i z e t h e fl a s h m e m o r y u s i n g t h e system status display, it is reset
ページ16に含まれる内容の要旨
T12 disabled/enabled setting Input status display Some condenser microphones used for video field re- On the input status display, not only you can see the cur- cording, such as the Sennheiser 416T, require T12 (AB- rent status of the following switches, but also you can 12V) power. The FM-3 can supply the T12 power. disable or enable the T12 power supply function. The fol- lowing shows the default setting when the unit is shipped. Unlike the phantom power (P48), connecting a dynamic micropho
ページ17に含まれる内容の要旨
Output status display : If you switch the microphone power supply switch of INPUT 1 to “T12”, the input sta- On the output status display, not only you can see the tus display changes as below. current status of the following switches, but also you can set the threshold and ratio of the limiter. The follow- ing shows the default setting when the unit is shipped. Front panel Right side panel If you set the microphone power supply switch of INPUT 1 to “T12” and set the microphone power
ページ18に含まれる内容の要旨
LIMITER parameter setting To select the threshold value: By setting the [LIMITER] switch to “ON” (or “LINK”), the lim- iter function is enabled and you can apply the limiter to the Flashing stereo L/R buss. The threshold level and ratio (compression ratio) of the lim- iter are set to “+12” and “5.1” respectively by default. Press the [+] key Press the [-] key : In the following description, it is assumed that the [LIMITER] switch on the front panel is set to “ON” and the input Flashing
ページ19に含まれる内容の要旨
In the following display example, both the left and right Meter status display peak meters are set to “ ”. On the meter status display, not only you can see the cur- See “Parameter details” below for the available options rent status of the metering, but also you can set param- of each parameter. eters. The following shows the default setting when the unit is shipped. Flashing (4) After editing parameters, press the [EDIT] key long e n o u g h t o s t o p fl a s h i n g . (5)
ページ20に含まれる内容の要旨
Lighting level of peak over indicator System status display On the system status display, not only you can see the The default is “+18 dB”. You can select between “0 dB” following information, but also you can reset the time and “+18 dB” in 1 dB steps. d i s p l a y a n d i n i t i a l i z e t h e fl a s h m e m o r y . : When peak level exceeds the lighting level, “OVER” is lit on the stereo meter display, as pointed by an arrow in the stereo meter display example below